Amendment 29 to Updated Final Safety Analysis Report, Chapter 10, Table 10.21, Paass In-Line Instrumentation
ML21286A517
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 10/04/2021
From:
Tennessee Valley Authority
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21286A574 List: ... further results
References
Download: ML21286A517 (1)


Text

BFN-16 Table 10.21-1 PASS In-Line Instrumentation Liquid Sample Mode Instrument Description Range Purpose FI-664 Flow 0-2 gpm Line flush flow rate CI-663 Conductivity 0-10 s/gpm Sample conductivity PI-661 Pressure 0-1200 psig Sample pressure PI-662 Pressure 0-150 psia Dissolved gas collect-ion chamber pressure RI-665 Radiation 10-100,000 mr/hr Approximate radiation level of sample line in liquid sampler, used also to verify system flush TI-660 Temperature 50-150°F Sample line temperature Gas Sample Mode Instrument Description Range Purpose FI-725 Flow 2-25 slpm Calibrate pump dis-charge pressure versus sample flow rate (not used during normal operation PI-708 Pressure 0-50 psia Sample pressure TI-724 Temperature 50-150°F Sample line temperature