MONTHYEARML21209A9332021-07-27027 July 2021 PWROG-18068-NP, Rev. 1, Use of Direct Fracture Toughness for Evaluation of RPV Integrity Project stage: Request ML21209A9322021-07-27027 July 2021 PWR Owners Group - Submittal of PWROG-18068-NP, Revision 1, Use of Direct Fracture Toughness for Evaluation of RPV Integrity Project stage: Request ML24068A1032021-07-31031 July 2021 Enclosure 2 - Markup of PWROG-18068-NP, Revision 1 Associated with the RAI Responses (Non-Proprietary) Project stage: Other ML24068A1042021-07-31031 July 2021 Enclosure 3 - Markup of PWROG-18068-NP, Revision 1 with No Text Deletions Shown (Non-Proprietary) Project stage: Other ML21243A5712021-09-0202 September 2021 Email Acceptance Review for PWROG-18068 TR Project stage: Acceptance Review ML21243A5722021-09-0202 September 2021 PWROG-18068 TR Acceptance Review Form Project stage: Acceptance Review ML22084A2462022-03-30030 March 2022 NRCs RAI by the NRR on Topical Report PWROG-18068-NP, Rev. 1, Use of Direct Fracture Toughness for Evaluation of RPV Integrity for the Pressurized Water Reactor Owners Group Project No. 99902937 Project stage: RAI ML22313A0592022-11-0202 November 2022 RAI Response Schedule Change for PWROG-18068-NP, Revision 1, Use of Direct Fracture Toughness for Evaluation of RPV Integrity (EPID L-2021-TOP-0027) (Email) Project stage: Other ML23180A1902023-06-29029 June 2023 PWROG-18068-NP, Revision 1, Markup June 2023 Project stage: Other ML23180A1612023-06-29029 June 2023 Draft RAI Responses to PWROG-18068-NP, Revision 1 Project stage: Draft RAI PMNS20230840, Notice of Observation Public Meeting Between the Pressurized Water Reactor Owners Group (PWROG) and the U.S. Nuclear Regulatory Commission (NRC) Regarding Topical Report PWROG-18068-NP, Revision 32023-07-28028 July 2023 Notice of Observation Public Meeting Between the Pressurized Water Reactor Owners Group (PWROG) and the U.S. Nuclear Regulatory Commission (NRC) Regarding Topical Report PWROG-18068-NP, Revision 3 Project stage: Request ML23270B8602023-10-0505 October 2023 Summary of August 4, 2023, NRC Public Observation Meeting with the Pressurized Water Reactor Owners Group to Discuss Clarification of Requests for Additional Information on Topical Report PWROG-18068-NP Project stage: RAI ML24008A0512024-01-12012 January 2024 Regulatory Audit Plan for the Review of Topical Report Pressurized Water Reactor Owners Group (PWROG) - 18068-NP, Revision 1, Use of Direct Fracture Toughness for Evaluation of Reactor Pressure Vessel Integrity, Project stage: Other ML24068A1022024-03-0808 March 2024 Enclosure 1 - RAI Responses Associated with PWROG-18068-NP Revision 1 (Non-Proprietary) Project stage: Other ML24068A1012024-03-0808 March 2024 Transmittal of the Responses to a Request for Additional Information, RAIs Associated with PWROG-18068-NP, Revision 1, Use of Direct Fracture Toughness for Evaluation of RPV Integrity Project stage: Request ML24060A3142024-07-19019 July 2024 Audit Report Summary for the Review of Topical Report PWROG-18068-NP, Revision 1, Use of Direct Fracture Toughness for Evaluation of Reactor Pressure Vessel Integrity Docket No. 99902037; Project stage: Approval ML24078A2052024-07-19019 July 2024 NRC Audit Report Transmittal Letter PWROG-18068 Jan 17-18 Project stage: Other ML24206A0422024-07-24024 July 2024 PWR Owners Group - Transmittal of Additional Changes to PWROG-18068-NP, Revision 1, Use of Direct Fracture Toughness for Evaluation of RPV Integrity Project stage: Request ML24068A1052024-08-0202 August 2024 Enclosure 4 - Draft PVP2024-125225 an Examination of Margins Needed to Ensure Conservative Application of T0 to RPV Fracture Toughness (Non-Proprietary) Project stage: Draft Other ML24275A0412024-10-0101 October 2024 PWR Owners Group - PWROG Comments on the Draft Safety Evaluation for PWROG-18068-NP, Revision 1, Use of Direct Fracture Toughness for Evaluation of RPV Integrity Project stage: Request ML24324A3532024-12-27027 December 2024 NRC Transmittal of the Final Safety Evaluation for PWROG-18068-NP, Revision 1 Project stage: Approval ML24324A1702024-12-27027 December 2024 NRR Final Safety Evaluation of Topical Report PWROG-18068-NP, Revision 1, Use of Direct Fracture Toughness for Evaluation of RPV Integrity for the Pressurized Water Reactor Owners Group Project stage: Approval ML25195A1322025-07-14014 July 2025 Verification Form for the Approved Topical Report PWROG-18068-NP Project stage: Other 2023-07-28
[Table View] |
Text
From:
Fields, Leslie To:
"Holderbaum, Chad M."; "Nowinowski, W Anthony" Cc:
Dijamco, David; Morey, Dennis; Widrevitz, Dan; Buford, Angie
Subject:
Acceptance Review Completed: Topical Report PWROG-18068, Use of Direct Fracture Toughness for Evaluation of RPV Integrity" Date:
Thursday, September 02, 2021 11:35:00 AM Attachments:
PWROG-18068 TR Acceptance Review Form final clean.pdf Mr. W. Anthony Nowinowski, Program Manager PWR Owners Group, Program Management Office Westinghouse Electric Company 1000 Westinghouse Drive, Suite 380 Cranberry Township, PA 16066
Dear Mr. Nowinowski,
By letter dated July 27, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21209A932), the Pressurized Water Reactor Owners Group (PWROG) submitted Topical Report (TR) PWROG-18068 -P/NP, Revision 1, Use of Direct Fracture Toughness for Evaluation of RPV Integrity, to the U.S. Nuclear Regulatory Commission (NRC) staff for review and approval.
In accordance with NRC's process as described in LIC-109, "Acceptance Review Procedures," the NRC staff has reviewed PWROGs submittal and determined that there is sufficient technical information in scope and depth to begin the technical review. Based on the complexity of the review, the NRC review team has determined a 15-month review schedule is appropriate.
Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. Currently, the NRC staff plans to issue a request for additional information (RAI) by March 15, 2022, and after receipt of RAI responses, NRC plans to transmit the draft safety evaluation (SE) by July 30, 2022. This schedule information takes into consideration NRCs current review priorities and available technical resources which may be subject to change. If modifications to these dates are deemed necessary, we will provide revisions/updates to this information.
As with all TRs, the SE will be reviewed by the NRCs Office of the General Counsel (OGC) to determine whether it falls within the scope of the Congressional Review Act (CRA).
During the course of this review, OGC considers whether any endorsement or acceptance of a TR by the NRC amounts to a rule as defined in the CRA. If this initial review concludes that the SE, with its accompanying TR, may be a rule, the NRC will forward the package to the Office of Management and Budget (OMB) for further review and consideration. Any review by OMB would impact the schedule for the issuance of the final SE.
If you have questions regarding this matter, please contact Leslie Fields at (301)415-1186.
Sincerely, Leslie C. Fields US NRC
301.452-3970 leslie.fields@nrc.gov