Southern Nuclear Operating Company ND-21-0392 Vogtle Electric Generating Piant (VEGP) Unit 3 CB&I Procedure Qualification Record 14162 (VEGP 3-ALT-16)
(This Enclosure consists of 8 pages, including this cover page)
m PROCEDURE QUALIFICATION RECORD To A.S.M.E.Section IX ESSENTIAL VARIABLES ND-21-0392 CB&I Procedure Qualification Record 14162 VEGP3-ALT-16 Page 2 of 8 14162 SMAW PQR No.
Process Material specification ASME P No.
1, Gp. 3 To ASME P No.
Thickness(if pipe, dia and wall thick) 1.125" Filler metal group no. F 4
Weld metal analysis no. A ASME specification no. SFA AWS specification no. A 1
5.1 5.1 Manual] X l Machine] l Auto.]
] Semiauto.
SA738 Gr. B to SA516 Gr. 60/70 Flux or Atmosphere N/A 1, Gp. 1/2 Flux trade name
Inert gas composition Flow rate Preheat temperature range Postweld heat treatment Plate edge preparation N/A N/A
- 72°F-264°F(IPT)
None Oxy Fuel burned Single or multiple pass WELDING PROCEDURE Multiple Single or multiple arc Single Position 2G Mode of transfer for GMAW:
Sprayf
)
Filler Metal for GTAW or PAW N/A Electrode E7018 Globular]
]
Pulsating]
]
Filler metal diameter Electrode diameter Short Circuit]
]
N/A 3/32" None Welding current Type of backing Consult WELDING VARIABLES for joint dimensions and welding current settings.
TEST RESULTS Reduced Section Tensile Results Direct C urrent / Electrode Positive (Reverse Polarity)
Dimensions, in.
Ultimate Ultimate Unit Character of Failure Specimen No.
Area Total Load Stress and Location Width Thickness in^
Kips ksi MPa P23402 1
0.743 1.042 0.774 61.9 80.0 551.6 Ductile Weld Metal P23402 2
0.741 1.044 0.774 62 80.2 553.0 Ductile Weld Metal
Guided Bend Test 1
DC Result Type Result 4
Transverse Side Bends 4
OK Scott L. Kirman Welder's name Welder's name
~
Who by virtue of these tests meets welder performance requirements.
Work Order (Grig. WPS) No.
P23402 Rev.
1 Welder's symbol Welder's symbol SLK We certify that the statements in this record are correct and that the test weld was prepared, welded and tested In accordance with the requirements of Section IX of the ASME code.
Signed CB&I Patrick Ho Remarks Date May 13, 2021 Excalibur 7018 MR (E7018) by Lincoln (Lot No. 1443Z)
SA738 Gr. B heat treatment: Quenched & Tempered SA516 Gr. 60/70 heat treatment: Normalized This PQR is qualified using a material which is dual certified as SA516 Gr. 60 (Pl.Gp.l) and SA516 Gr. 70 (P-1, Gp.2)
No preheat applied Form Number: CMS-830-15-FM-16008
PROCEDURE QUALIFICATION RECORD To A.S.M.E.Section IX ESSENTIAL VARIABLES ND-21-0392 CB&I Procedure Qualification Record 14162 VEGP3-ALT-16 Page 3 of 8 SIDE I I
1/8 "
Tl'
<jn It Scale 1:1 Position 2G Land:
Gap:
Tectinique:
1/8" 1/8" Stringer Side Pass Electrode Amps Volts Travel Heat Input Remarks Type Size Speed in mm in/min cm/min KJ/in KJ/cm 1
1 ETC 18 3/32 2.4 103 22.2 3.5 8.9 39.0 15.4 1
2 E7018 3/32 2.4 103 21.5 8.1 20.5 16.5 6.5 1
3 E7018 3/32 2.4 103 22,0 6.1 15.5 22.3 8.8 1
4 E7018 3/32 2.4 101 23,1 6.8 17.2 20.7 8.1 1
5 E7018 3/32 2.4 102 22.7 6.1 15.5 22.8 9.0 1
6 E7018 3/32 2.4 102 23.2 6.3 15.9 22.7 8.9 1
7 E7018 3/32 2.4 102 23.1 11.4 28.9 12.4 4.9 1
8 E7018 3/32 2.4 103 23.6 7.8 19.8 18.7 7.4 1
9 E7018 3/32 2.4 103 21.8 5.7 14.4 23.7 9.3 1
10 E7018 3/32 2.4 102 23.1 5.1 13.0 27.7 10.9 1
11 E7018 3/32 2.4 102 23.0 6.1 15.5 23.1 9.1 1
12 E7018 3/32 2.4 103 22.2 6.9 17.6 19.8 7.8 1
13 E7018 3/32 2.4 102 23.6 W/O No.
P23402 Qualification No.
14162 Date:
May 13, 2021 By:
Patrick Hou' Form Number: CMS-830-15-FM-16008
PROCEDURE QUALIFICATION RECORD To A.S.M.E.Section IX ESSENTIAL VARIABLES ND-21-0392 CB&I Procedure Qualification Record 14162 VEGP3-ALT-16 Page 4 of 8 Side Pass Electrode Volts Travel Speed Heat Input Remarks Type Size Amps in mm in/min cm/min KJ/in KJ/mm 2
1 E7D18 3/32 2.4 103 21.4 4.3 10.9 30.7 1.2 2
2 E7018 3/32 2.4 103 21.3 7.8 19.8 16.8 0.7 2
3 E7018 3/32 2.4 102 23.0 4.9 12.5 28.7 1.1 2
4 E7018 3/32 2.4 103 23.6 6.3 15.9 23.3 0.9 2
5 E7018 3/32 2.4 102 21.4 5.1 13.0 25.7 1.0 2
6 E7G18 3/32 2.4 102 21.4 5.1 13.0 25.7 1.0 2
7 E7018 3/32 2.4 102 23.8 10.4 26.5 14.0 0.6 2
8 E7018 3/32 2.4 102 22.8 7.4 18.7 19.0 0.7 2
9 E7018 3/32 2.4 103 22.1 6.1 15.5 22.4 0.9 2
10 E7018 3/32 2.4 102 22.2 5.8 14.8 23.4 0.9 2
11 E7018 3/32 2.4 103 22.2 7.8 19.8 17.6 0.7 2
12 E7018 3/32 2.4 102 22.2 7.8 19.8 17.4 0.7 W/0 No.
P23402 Qualification No.
14162 Date:
May 13, 2021 By:
Patrick Hou Form Number: CMS-830-15-FM-16008
PROCEDURE QUALIFICATION RECORD IMPACT TEST REPORT Type of Notch: Vee ND-21-0392 CB&I Procedure Qualiflcatlon Record 14162 VEGP3-ALT-16 Page 5 of 8 Spec.
No.
Spec.
Orient Spec.
Size Notch Location Side Depth Test Temp Deg F Energy Lateral Expansion Percent Shear Ft-Lb J
Mils mm A1
FULL WM 1
3/8"
-30 85.26 116 58 1.473 60 A2
FULL WM 1
3/8"
-30 66.18 90 50 1.270 50 A3
FULL WM 1
3/8"
-30 98.51 134 62 1.575 60 SA738 Gr. B B1 Long.
FULL HAZ 1
1/4T
-30 130.77 177 65 1.651 70 B2 Long.
FULL HAZ 1
1/4T
-30 125.25 170 64 1.626 65 B3 Long.
FULL HAZ 1
1/4T
-30 111.6 151 59 1.499 60 SA516 Gr. 60/70 01 Long.
FULL HAZ 1
1/4T
-30 94.34 128 84 2.134 85 02 Long.
FULL HAZ 1
1/4T
-30 100.95 137 83 2.108 85 03 Long.
FULL HAZ 1
1/4T
-30 86.71 118 77 1.956 80 Remarks:
W/0 No.
Qualification No.
Date:
P23402 14162 May 13, 2021 By:
Patrick Houginton Form Number: CMS-830-15-FM-16008
PROCEDURE QUALIFICATION RECORD VICKERS HARDNESS REPORT
( 10 Kg. LOAD)
ND-21-0392 CB&I Procedure Qualification Record 14162 VEGP3-ALT-16 Page 6 of 8 POSITION 2G Side 1 Side 2 Root
- 1. BM 208
- 16. BM 248
- 31. BM 214
- 2. BM 203
- 17. BM 250
- 32. BM 221
- 3. BM 206
- 18. BM 254
- 33. BM 219
- 4. HAZ 215
- 19. HAZ 251
- 34. HAZ 221
- 5. HAZ 256
- 20. HAZ 241
- 35. HAZ 216
- 6. HAZ 328
- 21. HAZ 328
- 36. HAZ 241
- 7. WM 234
- 22. WM 228
- 37. WM 230
- 8. WM 202
- 23. WM 230
- 38. WM 227
- 9. WM 222
- 24. WM 204
- 39. WM 223
- 10. HAZ 347
- 25. HAZ 388
- 40. HAZ 219
- 11. HAZ 202
- 26. HAZ 246
- 41. HAZ 188
- 12. HAZ 168
- 27. HAZ 174
- 42. HAZ 184
- 13. BM 164
- 28. BM 168
- 43. BM 156
- 14. BM 166
- 29. BM 164
- 44. BM 150
- 15. BM 166
- 30. BM 163
- 45. BM 148 Side I SA5I6 Gr. 60/7(1)4,^^
i 3 SA738 Gr
<5>2 P23402 W/0 No.
Qualification No.
Date:
May 13, 2021 14162 By:
Patrick Hougl Form Number: CMS-830-15-FM-16008
PROCEDURE QUALIFICATION RECORD BRINELL SURFACE HARDNESS REPORT (3000 kg LOAD 10mm INDENTER)
ND-21-0392 CB&I Procedure Qualification Record 14162 VEGP3-ALT-16 Page 7 of 8 POSITION 2G Side 1
- 1. BM
- 2. HAZ
- 3. WM
- 4. HAZ
- 5. BM 197 237 211 193 158 Side 2
- 6. BM
- 7. HAZ
- 8. WM
- 9. HAZ
- 10. BM 227 238 208 225 157 Side 2 W/0 No.
Qualifioation No.
Date:
P23402 14162 May 13, 2021 By:
Patrick Hougnton Form Number; CMS-830-15-FM-16008
PROCEDURE QUALIFICATION RECORD METALLOGRAPHY REPORT Macrophotograph ND-21-0392 CB&I Procedure Qualification Record 14162 VEGP 3-ALT-16 Page 8 of 8 SA516 Gr. 60/70
!C> ^
J Ct>>
o CO o
r-o to o
to HAZ minimum width: 1.5mm HAZ maximum width: 3.75mm SA738 Gr. B Scale Increment:
0.5mm Etchant:
Finish:
Photomacrograph:
5% Nital 1 micron Cross-section of an SMAW weld seam.
P23402 W/0 No.
Qualification No.
Date:
May 13, 2021 14162 By:
Patrick Form Number: CMS-830-15-FM-16008