ES-401 FY21 Nine Mile Point Unit 2 Written Examination Review Worksheet Form ES-401-9 Q

1. LOK (F/H)
2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6. Source (B/M/N)
7. Status (U/E/S)
8. Explanation Stem Focus Cues T/F Cred.

Dist Partial Job-Link Minutia

  1. /Units Backward Q - K/A SRO Only 1

F 2

Y B

E Modified stem conditions 2

F 3

Y N

E Modified Distractors B and D, added noun name.

3 H

2 Y

B E

Added justification for K/A match 4

H 3

Y N

E Added justification for K/A match 5

F 3

Y M

E Modified B and D distractors 6

F 3

Y M

S 7

F 3

Y N

E Modified Distractor D 8

H 2

Y B

E Modified stem and distractors to avoid overlap with Q52 Refer to Section D of ES-401 and Appendix B for additional information regarding each of the following concepts:

1.

Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.

2.

Enter the level of difficulty (LOD) of each question a 1 (easy) to 5 (difficult); questions with a difficulty between 2 and 4 are acceptable.

3.

Check the appropriate box if a psychometric flaw is identified:

Stem Focus: The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).

Cues: The stem or distractors contain cues (e.g., clues, specific determiners, phrasing, length).

T/F: The answer choices are a collection of unrelated true/false statements.

Cred. Dist.: The distractors are not credible; single implausible distractors should be repaired, and more than one is unacceptable.

Partial: One or more distractors are partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by the stem).

4.

Check the appropriate box if a job content flaw is identified:

Job Link: The question is not linked to the job requirements (i.e., the question has a valid K/A but, as written, is not operational in content).

Minutia: The question requires the recall of knowledge that is too specific for the closed-reference test mode (i.e., it is not required to be known from memory).

  1. /Units: The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).

Backward: The question requires reverse logic or application compared to the job requirements.

5.

Check questions that are sampled for conformance with the approved K/A and those K/As that are designated SRO-only. (K/A and license-level mismatches are unacceptable.)

6.

Enter questions source: (B)ank, (M)odified, or (N)ew. Verify that (M)odified questions meet the criteria of Form ES-401, Section D.2.f.

7.

Based on the reviewers judgment, is the question, as written, (U)nsatisfactory (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?

8.

At a minimum, explain any U status ratings (e.g., how the Appendix B psychometric attributes are not being met).

ES-401 FY21 Nine Mile Point Unit 2 Page 2 Form ES-401-9 Q

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6. Source (B/M/N)
7. Status (U/E/S)
8. Explanation Stem Focus Cues T/F Cred.

Dist Partial Job-Link Minutia

  1. / Units Backward Q - K/A SRO Only 9

H 3

Y N

E Modified distractors to make applicant compare HUR to TS limit 10 F

3 X

Y N

E Modified distractors A&C 11 F

2 Y

B E

Added explainer for K/A match, modified distractor D

12 H

2 Y

B E

Modified stem value for transmitter C 13 F

3 Y

N E

Modified Distractors C &

D 14 H

3 Y

B S

15 H

3 Y

B E

Reordered answers A & B 16 F

2 Y

B E

Added KA justification statement 17 H

3 Y

B E

Modified stem and Distractor B 18 F

2 Y

B S

19 F

2 Y

B S

20 H

3 Y

N E

Added info for lowest RPV water level to stem 21 F

3 Y

B S

22 H

2 Y

B E

Reconfigured distractors 23 H

2 Y

N S

24 F

2 Y

B S

25 H

3 Y

N E

Modified stem to make generic control rod vice center rod

ES-401 FY21 Nine Mile Point Unit 2 Page 3 Form ES-401-9 Q

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6. Source (B/M/N)
7. Status (U/E/S)
8. Explanation Stem Focus Cues T/F Cred.

Dist Partial Job-Link Minutia

  1. / Units Backward Q - K/A SRO Only 26 H

2 Y

B E

Added noun names for MSIVs to stem bullets 27 H

2 Y

B E

Enhanced Stem to Give Time When Header Pressure Was Lost 28 H

3 Y

N S

Added trends to stem parameters 29 H

3 Y

N S

30 H

3 Y

M S

31 F

3 Y

N S

32 H

2 Y

B E

Modified first bullet in stem (corrected vs indicated) 33 H

2 Y

B S

34 H

2 Y

B E

Added better photos 35 H

3 Y

N S

36 H

2 Y

B E

Reformatted stem 37 H

3 Y

B S

38 H

3 Y

N S

39 F

3 Y

B S

40 F

3 Y

N S

41 H

3 Y

M S

42 F

3 Y

N S

ES-401 FY21 Nine Mile Point Unit 2 Page 4 Form ES-401-9 Q

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6. Source (B/M/N)
7. Status (U/E/S)
8. Explanation Stem Focus Cues T/F Cred.

Dist Partial Job-Link Minutia

  1. / Units Backward Q - K/A SRO Only 43 F

2 Y

B S

44 F

2 Y

B S

45 H

3 Y

N S

46 H

2 Y

B S

47 F

3 Y

B S

48 F

3 Y

N S

49 H

2 Y

B S

50 F

3 Y

M S

51 F

2 Y

B U S POSSIBLE NO CORRECT ANSWER, rewrote distractors to ensure only one correct answer 52 H

3 Y

N S

53 F

3 Y

N S

54 F

2 Y

B S

55 H

3 Y

B S

56 H

3 Y

N E

Modified Distractors C &

D to match format of A &

C 57 F

3 Y

B S

58 F

2 Y

B E

Modified distractors to 2X2 format

ES-401 FY21 Nine Mile Point Unit 2 Page 5 Form ES-401-9 Q

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6. Source (B/M/N)
7. Status (U/E/S)
8. Explanation Stem Focus Cues T/F Cred.

Dist Partial Job-Link Minutia

  1. / Units Backward Q - K/A SRO Only 59 F

3 Y

N S

60 H

3 Y

N E

Modified stem to change status of min flow valve to mid-position 61 H

2 Y

B S

62 H

2 Y

N E

Modified stem and rearranged distractors to a 2X2 format 63 F

3 X

Y N

U S Series of T/F Qs, rewrote stem and distractors 64 H

2 Y

B S

65 F

3 Y

N S

66 H

3 Y

B S

67 F

2 Y

B S

68 H

2 Y

B E

Changed you to an operator in stem, reformatted distractors to 2X2 69 F

3 Y

B U S QUESTIONS RELATED TO LIMITING MCPR wrote new question 70 H

3 Y

M S

71 F

2 Y

B E

Added time frame to stem 72 F

2 Y

B U S Too system specific for T3, wrote new question 73 H

3 Y

M S

74 F

2 Y

B E

Modified distractor B & C

ES-401 FY21 Nine Mile Point Unit 2 Page 6 Form ES-401-9 Q

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6. Source (B/M/N)
7. Status (U/E/S)
8. Explanation Stem Focus Cues T/F Cred.

Dist Partial Job-Link Minutia

  1. / Units Backward Q - K/A SRO Only 75 H

2 Y

B S

76 H

2 Y

Y B

E Modified distractors C&D 77 H

3 Y

Y N

E Rearranged stem 78 H

3 Y

Y N

E Added power level to stem 79 H

3 Y

Y B

S 80 F

1 Y

Y N

U S LOD=1 wrote new question 81 H

2 Y

Y B

E Modified stem value for DW temperature. Modified distractor D construction to parallel the other answers 82 H

2 Y

Y B

E Modified stem to Corp ED, Modified Distractors B & D PAR times 83 H

3 Y

N N

U S NOT SRO ONLY SYSTEM KNOWLEDGE AND ENTRY CONDITIONS rewrote Q to focus on procedure selection 84 H

2 Y

Y N

S 85 H

2 Y

Y B

S 86 H

2 Y

Y B

U S DISTRACTOR C MAY BE A CORRECT ANSWER reconfigured to 2X2 to eliminate 2nd correct answer 87 H

3 Y

Y N

U S POSSIBLE TWO CORRECT ANSWERS added NO operator action to stem to eliminate 2nd correct answer

ES-401 FY21 Nine Mile Point Unit 2 Page 7 Form ES-401-9 Q

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6. Source (B/M/N)
7. Status (U/E/S)
8. Explanation Stem Focus Cues T/F Cred.

Dist Partial Job-Link Minutia

  1. / Units Backward Q - K/A SRO Only 88 H

2 Y

Y B

E Deleted note on Figure A 89 H

2 Y

Y B

S 90 F

3 Y

Y N

E Modified distractors to eliminate specific determiner 91 H

1 Y

Y N

U S LOD=1. Resampled for new K/A 92 H

3 Y

Y N

U S PROVIDED REFERENCE GIVE AWAY ANSWER Removed reference 93 H

3 Y

N Y B

U S NOT SRO ONLY, NO PROCEDURE SELECTION D NOT PLAUSIBLE Added procedure to stem, modified all distractors 94 H

2 Y

Y B

S 95 H

2 Y

Y B

E Modified distractor B, and graphic of fuel cell 96 F

3 X

Y Y

M E

Modified stem to improve focus, added info to Distractors A & B 97 H

3 Y

Y M

S 98 H

2 Y

Y B

U S NOT TIER 3, SHOULD ADDRESS release permit procedure Resampled for K/A, wrote new Q 99 H

2 Y

Y B

S 100 F

3 Y

Y N

E Changed Facilities to the individual