Southern Nuclear Operating Company ND-21-0342 Enclosure 1 Emergency Response Data System(ERDS)Data Point Library For Vogtle Unit 3 (This Enclosure consists of 107 pages, not including this cover page)

ND-21-0342 Southern Nuclear Operating Company Emergency Response Data System

[ERDS]

Data Point Library For Vogtle Unit 3 April 12,2021 NOTE:

Changes to the information presented herein may require NRG notification per 10 CFR 50,Appendix E,Section VI.

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 REFERENCES

1. NUREG-1394, Rev. 1,"Emergency Response Data System (ERDS]Implementation"
2. APP-DDS-J4-157, Rev. 2,"Data Display and Processing System Emergency Response Data System Datalink Interface Specification"

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: CORE FLOW Point iD: DDS-FLC46-F0 Piant Spec Point

Description:

Total RCS Corrected Flow Rate Generic/Cond

Description:

Total Reactor Coolant Flow Analog/Digitai: A ENGR Units/Dig States: gpm ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 1000000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 8 How Processed: COMPENSATED BASED ON REACTOR POWER Sensor Locations: ROOM 11204(101A/B/C/D) ROOM 11202(102A/B/C/D)

Alarm/Trip Setpoints: NONE FOR CORR. FLOW,INSTR LOW(95% OF FLOW)

Nl Detector Power Supply Cut-off N/A Power Levei:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 1 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: RCS PRESSURE Point ID: PMS-WRPR-RA-P6 Plant Spec Point

Description:

RCS Wide Range Pressure Generic/Cond

Description:

Reactor Coolant System Pressure Analog/Digital: A ENGR Units/Dig States: psig ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 3300 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: AVERAGE Sensor Locations: ROOM 11400(PT140A/C) ROOM 11306(PT140B/D)

Alarm/Trip Setpoints: LOW 2(700 PSIG) LOW 3(450 PSIG)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 2 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: BDS-RY010 Plant Spec Point

Description:

EDI Product Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum Instr Range: 1e-07 Maximum Instr Range: 0.01 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: ROOM 21380 Alarm/Trip Setpoints: HIGH (2E-007 UCI/CC)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 3 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: BDS-RY011 Plant Spec Point

Description:

EDI Reject Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum Instr Range: 1e-07 Maximum Instr Range: 0.01 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: ROOM 21380 Alarm/Trip Setpoints: HIGH (2E-007 UCI/CC)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 4 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: CVS-FT157A Plant Spec Point

Description:

Makeup Pump Disch Header HR Flow Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States: gpm ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 175 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: ROOM 12255 Aiarm/Trip Setpoints: NONE Ni Detector Power Suppiy Cut-off N/A Power Level:

NI Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 5 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: Ni SOURC RNG Point iD: DDS-RSA39-N1 Riant Spec Point

Description:

Source Range Detector Generic/Cond

Description:

Nuclear Instruments, Source Range Anaiog/Digitai: A ENGR Units/Dig States: cps ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum instr Range: 1000000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 4 How Processed: N/A Sensor Locations: ROOM 11105 Alarm/Trip Setpoints: 5X BASE COUNT SETPOINT OR ALL CHANNELS 2X GREATER THAN CPS Nl Detector Power Suppiy Cut-off N/A Power Levei:

Ni Detector Power Suppiy Turn-on N/A Power Levei:

instrument Faiiure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 6 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: Nl POWER RNG Point ID: DDS-RSA3J-J1 Plant Spec Point

Description:

Power Range Power(Compensated)

Generic/Cond

Description:

Nuclear Instruments, Power Range Analog/Digital: A ENGR Units/Dig States:  % power ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 160 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 8 How Processed: N/A Sensor Locations: ROOM 11105 Alarm/Trip Setpoints: NONE Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 7 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PMS-TSAT-T1 Plant Spec Point

Description:

RCS Saturation Temperature Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum Instr Range: 212 Maximum Instr Range: 710 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpolnts: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 8 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: TEMP CORE EX Point iD: PMS-CETC-TH-T6 Plant Spec Point

Description:

Fifth Hottest Core Exit Thermocouple Generic/Cond

Description:

Highest Temperature at the Core Exit Anaiog/Digitai: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum instr Range: 70 Maximum Instr Range: 2300 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 38 How Processed: COMPARISON,5TH HOTTEST SELECTED Sensor Locations: ROOM 11105 Aiarm/Trip Setpoints: NONE Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 9 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PMS-IRSL-RA-L6 Plant Spec Point

Description:

IRWST Water Level Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States:  %

ENGR Units Conversion: 1% =.24FT Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

SEALEV Reference Point Notes: 5.5 FT ABOVE TANK BOTTOM PROG or SENS: S Number of Sensors: 3 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: IRWST TANK Alarm/Trip Setpolnts: LOW(97%)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: DRY Unique System

Description:

N/A Page 10 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: Nl INTER RNG Point ID: PMS-NFLX-RA-N6 Plant Spec Point

Description:

Intermediate Range Neutron Flux Generic/Cond

Description:

Nuclear Instruments, Intermediate Range Analog/Digital: A ENGR Units/Dig States:  %

ENGR Units Conversion: N/A Minimum Instr Range: 1e-06 Maximum Instr Range: 200 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 4 How Processed: N/A Sensor Locations: ROOM 11105 Alarm/Trip Setpoints: NONE Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 11 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PMS-PRHF-RA-F6 Plant Spec Point

Description:

PRHR Heat Exchanger Flow Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: gpm ENGR Units Conversion: N/A Minimum Instr Range: 700 Maximum Instr Range: 3000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 2 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11300 Alarm/Trip Setpoints: NONE Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 12 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: PRZR LEVEL Point ID: PMS-PWLC-RA-L6 Plant Spec Point

Description:

Pressurizer Level Generic/Cond

Description:

Primary System Pressurizer Level Analog/Digital: A ENGR Units/Dig States:  %

ENGR Units Conversion: 1% = 4.2293 IN Minimum instr Range: 0 Maximum instr Range: 100 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11400(LT195A/C) ROOM 11306(LT195B/D)

Alarm/Trip Setpoints: COMPLICATED. BASED ON PLS/PMS LOGIC Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: WET Unique System

Description:

N/A Page 13 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: SUB MARGIN Point ID: PMS-SCMG-T5 Plant Spec Point

Description:

RCS Subcooiing Margin Generic/Cond

Description:

Saturation Temperature Analog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 250 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: N/A Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 14 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: CVS-FT157B Riant Spec Point

Description:

Makeup Pump Disch Header LR Flow Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: gpm ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum Instr Range: 60 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: ROOM 12255 Aiarm/Trip Setpoints: NONE Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 15 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: BWST LEVEL Point ID: CVS-LT109 Plant Spec Point

Description:

Boric Acid Storage Tank Level Generic/Cond

Description:

Borated Water Storage Tank Level Analog/Digital: A ENGR Units/Dig States:  %

ENGR Units Conversion: 1% = 1.8 IN Minimum instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

SEALEV Reference Point Notes: BOTTOM OF TANK PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: BAST TANK, OUTSIDE OF SV3 TRUCK BAY Alarm/Trip Setpoints: EMPTY(5%)LOW(93%) HIGH(97%)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: DRY Unique System

Description:

N/A Page 16 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PCS-LT040 Plant Spec Point

Description:

PCS Leak Chase Collection Pot Levei Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States:  %

ENGR Units Conversion: 1% = 0.28 IN Minimum instr Range: 0 Maximum instr Range: 100 Zero Point

Reference:

SEALEV Reference Point Notes: 0% = 2 IN, 100% = 30 IN PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: POT IN AUX BUILDING STAIRWELL S03 Aiarm/Trip Setpoints: HIGH(50%)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 17 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PCS-TE024-SEL Plant Spec Point

Description:

PCS Air Flow Discharge Temp Select Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum Instr Range: -40 Maximum Instr Range: 300 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 2 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ABOVE CNTMT IN AIR DISCH PATH ROOM 12541 Alarm/Trip Setpoints: NONE Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 18 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PCS-TE036 Plant Spec Point

Description:

PCS Reclrculatlon Heater Inlet Temp Generlc/Cond

Description:

NL Analog/Digital: A ENGR Unlts/DIg States: DEGF ENGR Units Conversion: N/A Minimum Instr Range: 25 Maximum Instr Range: 150 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: UPSTREAM OF THE PCS RECIRC HEATER IN ROOM 12306 Alarm/Trip Setpolnts: LOW (47.25 DEGF)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 19 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PXS-TE064 Plant Spec Point

Description:

PRHR MX inlet High Point Temperature Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum Instr Range: 50 Maximum Instr Range: 650 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: TOP OF PRHR HX INLET LINE DOWNSTREAM OF V101 ROOM 11500 Alarm/Trip Setpoints: LOW(428 DEGF)HIGH (563 DEGF)

Nl Detector Power Supply Gut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 20 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: ML LEVEL 1/A Point ID: RCS-LT160A Plant Spec Point

Description:

RCS Hot Leg 1 Level Sensor Generic/Cond

Description:

Hot Leg 1 (or A)Water Level Analog/Digital: A ENGR Units/Dig States:  % span ENGR Units Conversion: 1% = 0.31 IN Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

SEALEV Reference Point Notes: BOTTOM OF HL PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: ROOM 11204, Alarm/Trip Setpoints: LOW 1 (64.5%)LOW 3(16.1%)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: WET Unique System

Description:

N/A Page 21 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: ML LEVEL 2/B Point ID: RCS-LT160B Plant Spec Point

Description:

RCS Hot Leg 2 Level Sensor Generic/Cond

Description:

Hot Leg 2(or B)Water Level Analog/Digital: A ENGR Units/Dig States:  % span ENGR Units Conversion: 1% = 0.31 IN Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

SEALEV Reference Point Notes: BOTTOM OF HL PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: ROOM 11202, UPSTREAM OF RNS CONNECTION Alarm/Trip Setpoints: LOW 1 (64.5%) LOW 3(16.1%)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: WET Unique System

Description:

N/A Page 22 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: CL TEMP 1/A Point iD: RCS-TE125A2 Piant Spec Point

Description:

RCS Wide Range Coid Leg 1A Temperature Generic/Cond

Description:

Stm Gen 1 (or A)Outiet Temperature Analog/Digitai: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum instr Range: 50 Maximum instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: ROOM 11201, INSIDE COLD LEG 1A Aiarm/Trip Setpoints: NONE Ni Detector Power Suppiy Cut-off N/A Power Levei:

Ni Detector Power Supply Turn-on N/A Power Levei:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 23 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: CL TEMP 2/B Point iD: RCS-TE125B2 Piant Spec Point

Description:

RCS Wide Range Cold Leg 2A Temperature Generic/Cond

Description:

Stm Gen 2(or B)Outlet Temperature Analog/Digitai: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum instr Range: 50 Maximum instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: ROOM 11202, INSIDE COLD LEG 2A Alarm/Trip Setpoints: NONE Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 24 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: PMS-ADS1-AC Piant Spec Point

Description:

ADS Stage 1 Actuation Generic/Cond

Description:

NL Anaiog/Digital: D ENGR Units/Dig States: Digital ENGR Units Conversion: N/A Minimum instr Range: 0=NORMAL Maximum instr Range: 1=ACT Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: 2 OUT OF 4 VOTING LOGIC Sensor Locations: ROOM 11703 185 ELV (V001A)ROOM 11603 160.5 ELV(V001B)

Aiarm/Trip Setpoints: NONE Ni Detector Power Suppiy Cut-off N/A Power Level:

Ni Detector Power Suppiy Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 25 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PMS-ADS2-AC Plant Spec Point

Description:

ADS Stage 2 Actuation Generic/Cond

Description:

NL Analog/Digital: D ENGR Units/Dig States: Digital ENGR Units Conversion: N/A Minimum Instr Range: 0=NORMAL Maximum Instr Range: 1=ACT Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: 2 OUT OF 4 VOTING LOGIC Sensor Locations: ROOM 11703 185 ELV (V002A) ROOM 11603 160.5 ELV(V002B)

Alarm/Trip Setpoints: NONE Ni Detector Power Supply Cut-off N/A Power Level:

NI Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 26 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PMS-ADS3-AC Plant Spec Point

Description:

ADS Stage 3 Actuation Generlc/Cond

Description:

NL Analog/Digital: D ENGR Unlts/DIg States: Digital ENGR Units Conversion: N/A Minimum Instr Range: 0=NORMAL Maximum Instr Range: 1=ACT Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: 2 OUT OF 4 VOTING LOGIC Sensor Locations: ROOM 11703 185 ELV(V003A) ROOM 11603 160.5 ELV(V003B)

Alarm/Trip Setpolnts: NONE Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 27 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PMS-ADS4-AC Plant Spec Point

Description:

ADS Stage 4 Actuation Generic/Cond

Description:

NL Analog/Digital: D ENGR Units/Dig States: Digital ENGR Units Conversion: N/A Minimum Instr Range: 0=NORMAL Maximum Instr Range: 1=ACT Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: 2 OUT OF 4 VOTING LOGIC Sensor Locations: ROOM 11301 ELV 118.5(V004A/C) ROOM 11302 ELV 118.5 (V004B/D)

Alarm/Trip Setpoints: NONE Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 28 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-RSA45-T1 Piant Spec Point

Description:

IRWST Surface Temperature RSA Generic/Cond

Description:

NL Anaiog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum instr Range: 50 Maximum instr Range: 300 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 2 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11305 Aiarm/Trip Setpoints: HIGH (110 DEGF)

Ni Detector Power Suppiy Cut-off N/A Power Level:

NI Detector Power Suppiy Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 29 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-RSA47-T1 Riant Spec Point

Description:

IRWST Bottom Temperature RSA Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum instr Range: 50 Maximum Instr Range: 300 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 2 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11305 Alarm/Trip Setpoints: HIGH (110 DEGF)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 30 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-RSA59-P1 Plant Spec Point

Description:

Accumulator Tank A Pressure RSA Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: psig ENGR Units Conversion: N/A Minimum Instr Range: 100 Maximum Instr Range: 800 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 2 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11206 Alarm/Trip Setpolnts: LOW(662 PSIG) HI(744 PSIG)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N/A Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 31 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-RSA61-P1 Piant Spec Point

Description:

Accumulator Tank B Pressure RSA Generic/Cond

Description:

NL Anaiog/Digital: A ENGR Units/Dig States: psig ENGR Units Conversion: N/A Minimum instr Range: 100 Maximum Instr Range: 800 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 2 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11207 Aiarm/Trip Setpoints: LOW(662 PSIG) Hi (744 PSIG)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N/A Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 32 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-RSA67-L1 Piant Spec Point

Description:

CMT A Narrow Range Upper Levei RSA Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States:  % span ENGR Units Conversion: 1% = 0.2 IN Minimum Instr Range: 0 Maximum instr Range: 100 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11400 Aiarm/Trip Setpoints: LOW(DEP)LOW 2(69.4%) LOW 3(DEP)

Ni Detector Power Suppiy Cut-off N/A Power Levei:

NI Detector Power Suppiy Turn-on N/A Power Levei:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 33 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-RSA71-L1 Piant Spec Point

Description:

CMT B Narrow Range Upper Levei RSA Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States:  % span ENGR Units Conversion: 1% = 0.2 iN Minimum instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAiLABLE PARAMETER Sensor Locations: ROOM 11400 Aiarm/Trip Setpoints: LOW(DEP)LOW 2(69.4%) LOW 3(DEP)

Ni Detector Power Suppiy Cut-off N/A Power Levei:

Ni Detector Power Suppiy Turn-on N/A Power Levei:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 34 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-RSA69-L1 Piant Spec Point

Description:

CMT A Narrow Range Lower Level RSA Generic/Cond

Description:

NL Analog/Digitai: A ENGR Units/Dig States:  % span ENGR Units Conversion: 1% = 0.379 IN Minimum instr Range: 0 Maximum instr Range: 100 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11400 Alarm/Trip Setpoints: LOW 4(91%)LOW 5(73.5%) LOW 6(DEP)

Nl Detector Power Suppiy Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 35 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-RSA73-L1 Riant Spec Point

Description:

CMT B Narrow Range Lower Level RSA Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States:  % span ENGR Units Conversion: 1% = 0.379 IN Minimum instr Range: 0 Maximum instr Range: 100 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11400 Aiarm/Trip Setpoints: LOW 4(91%)LOW 5(73.5%) LOW 6(DEP)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 36 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-RSA1F-T1 Riant Spec Point

Description:

CMT A Top Temperature RSA Generic/Cond

Description:

NL Analog/Digitai: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum Instr Range: 50 Maximum instr Range: 600 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 2 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11400 Aiarm/Trip Setpoints: Hi (107.5 DEG F)

Ni Detector Power Suppiy Cut-off N/A Power Levei:

NI Detector Power Suppiy Turn-on N/A Power Levei:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 37 of 105

ND-21-0342 ERDS Data Point Library For Vogtie Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-RSA1L-L1 Plant Spec Point

Description:

CMT B Top Temperature RSA Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum instr Range: 50 Maximum instr Range: 600 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 2 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11400 Alarm/Trip Setpoints: Hi (107.5 DEG F)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 38 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: MN FD FL 1/A Point iD: DDS-RSA17-F1 Piant Spec Point

Description:

SGI Hi Rng MFW Fiow RSA(Unc)

Generic/Cond

Description:

Stm Gen 1 (or A)Main Feedwater Fiow Analog/Digitai: A ENGR Units/Dig States: ibm/h ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum instr Range: 9000000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 3 How Processed: BEST AVAiLABLE PARAMETER Sensor Locations: ROOM 20400 Aiarm/Trip Setpoints: COMPLiCATED. BASED ON MULTiPLE CHANNELS Nl Detector Power Suppiy Cut-off N/A Power Levei:

Ni Detector Power Suppiy Turn-on N/A Power Levei:

instrument Faiiure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 39 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: MN FD FL 2/B Point ID: DDS-RSA21-F1 Piant Spec Point

Description:

SG2 Hi Rng MFW Flow RSA(Unc)

Generic/Cond

Description:

Stm Gen 2(or B)Main Feedwater Flow Anaiog/Digital: A ENGR Units/Dig States: Ibm/h ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 9000000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 3 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 20400 Aiarm/Trip Setpoints: COMPLICATED. BASED ON MULTIPLE CHANNELS Ni Detector Power Suppiy Cut-off N/A Power Levei:

Ni Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 40 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: SG PRESS 1/A Point ID: DDS-RSA91-P1 Plant Spec Point

Description:

SGI Steam Line Pressure RSA Generic/Cond

Description:

Steam Generator 1 (or A)Pressure Analog/Digital: A ENGR Units/Dig States: psig ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum instr Range: 1300 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 1100, ROOM 12405 Alarm/Trip Setpoints: LOW(620 PSIG)

Ni Detector Power Supply Gut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 41 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: SG PRESS 2/B Point ID: DDS-RSA93-P1 Plant Spec Point

Description:

SG2 Steam Line Pressure RSA Generlc/Cond

Description:

Steam Generator 2(or B)Pressure Analog/Digital: A ENGR Unlts/DIg States: psig ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1300 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 1100, ROOM 12406 Alarm/Trip Setpolnts: LOW(620 PSIG)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 42 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: SG LEVEL 1/A Point ID: PMS-S1NL-RA-L6 Plant Spec Point

Description:

Compensated NR SGI Water Level Generic/Cond

Description:

Steam Generator 1 (or A)Water Level Analog/Digital: A ENGR Units/Dig States:  % span ENGR Units Conversion: 1% = 2.5331 IN Minimum instr Range: 0 Maximum instr Range: 100 Zero Point

Reference:

TUBSHT Reference Point Notes: 383.64 IN ABOVE TUBE SHEET PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 1100 Alarm/Trip Setpoints: LOW(26%)LOW 2(21%) Hi(72.8%) Hi 2(77%) Hi 3(82%)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: WET Unique System

Description:

N/A Page 43 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: SG LEVEL 2/B Point ID: PMS-S2NL-RA-L6 Riant Spec Point

Description:

Compensated NR SG2 Water Level Generic/Cond

Description:

Steam Generator 2(or B)Water Level Anaiog/Digitai: A ENGR Units/Dig States:  % span ENGR Units Conversion: 1% = 2.5331 IN Minimum instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

TUBSHT Reference Point Notes: 383.64 IN ABOVE TUBE SHEET PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 1100 Alarm/Trip Setpoints: LOW(26%)LOW 2(21%) Hi (72.8%) Hi 2(77%) Hi 3(82%)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: WET Unique System

Description:

N/A Page 44 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: SG LEVEL 1/A Point iD: PMS-S1WL-RA-L6 Plant Spec Point

Description:

Compensated WR SGI Water Level Generic/Cond

Description:

Steam Generator 1 (or A)Water Level Anaiog/Digitai: A ENGR Units/Dig States:  % span ENGR Units Conversion: 1% = 6.2681 IN Minimum instr Range: 0 Maximum instr Range: 100 Zero Point

Reference:

TUBSHT Reference Point Notes: 10.14 IN ABOVE TUBE SHEET PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 1100 Alarm/Trip Setpoints: LOW(40%)LOW 2(35%) HI(95%)

Nl Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: WET Unique System

Description:

N/A Page 45 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: SG LEVEL 2/B Point ID: PMS-S2WL-RA-L6 Plant Spec Point

Description:

Compensated WR SG2 Water Level Generic/Cond

Description:

Steam Generator 2(or B)Water Level Analog/Digital: A ENGR Units/Dig States:  % span ENGR Units Conversion: 1% = 6.2681 IN Minimum instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

TUBSHT Reference Point Notes: 10.14 IN ABOVE TUBE SHEET PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 1100 Aiarm/Trip Setpoints: LOW(40%)LOW 2(35%) HI(95%)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: WET Unique System

Description:

N/A Page 46 of 105

ND-21-0342 ERDS Data Point Library For Vogtie Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: AX FD FL 1/A Point ID: PMS-S1SF-RA-F6 Plant Spec Point

Description:

SGI Startup Feedwater Flow Generic/Cond

Description:

Stm Gen 1 (or A)Auxiliary FW Flow Analog/Digital: A ENGR Units/Dig States: gpm ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 600 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 5 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 12211 Alarm/Trip Setpoints: LOW(210 GPM)LOW 2(200 GPM)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 47 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: AX FD FL 2/B Point iD: PMS-S2SF-RA-F6 Piant Spec Point

Description:

SG2 Startup Feedwater Flow Generic/Cond

Description:

Stm Gen 2(or B)Auxiliary FW Flow Anaiog/Digitai: A ENGR Units/Dig States: gpm ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 600 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 5 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 12211 Aiarm/Trip Setpoints: LOW(210 GPM)LOW 2(200 GPM)

Ni Detector Power Suppiy Cut-off N/A Power Levei:

Ni Detector Power Suppiy Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 48 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-HSilDS004-E1 Riant Spec Point

Description:

Max IDSA voltage IDSA-DV-1 Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: HIGHEST SELECTED Sensor Locations: N/A Aiarm/Trip Setpoints: N/A Ni Detector Power Suppiy Cut-off N/A Power Levei:

Ni Detector Power Suppiy Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 49 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-HSIiDS004-E5 Plant Spec Point

Description:

Min IDSA voltage IDSA-DV-1 Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum Instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: LOWEST SELECTED Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 50 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-HSIIDS008-E1 Plant Spec Point

Description:

Max IDSB voltage IDSB-DV-1 Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: HIGHEST SELECTED Sensor Locations: N/A Alarm/Trip Setpolnts: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 51 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-HSIIDS008-E5 Plant Spec Point

Description:

Min IDSB voltage IDSB-DV-1 Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: LOWEST SELECTED Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 52 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-HSiiDS012-E1 Plant Spec Point

Description:

Max IDSB voltage IDSB-DV-2 Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: HIGHEST SELECTED Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Gut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 53 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-HSIiDS012-E5 Plant Spec Point

Description:

Min IDSB voltage iDSB-DV-2 Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: LOWEST SELECTED Sensor Locations: N/A Aiarm/Trip Setpoints: N/A Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 54 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-HSIiDS016-E1 Piant Spec Point

Description:

Max IDSC voltage iDSC-DV-1 Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum Instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: HIGHEST SELECTED Sensor Locations: N/A Alarm/Trip Setpoints: N/A Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 55 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-HSilDS016-E5 Plant Spec Point

Description:

Min iDSC voitage iDSC-DV-1 Generic/Cond

Description:

NL Analog/Digitai: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: LOWEST SELECTED Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 56 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-HSIIDS020-E1 Plant Spec Point

Description:

Max IDSC voltage IDSC-DV-2 Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: HIGHEST SELECTED Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 57 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-HSIIDS020-E5 Plant Spec Point

Description:

Min IDSC voltage IDSC-DV-2 Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: LOWEST SELECTED Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 58 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-HSIiDS024-E1 Plant Spec Point

Description:

Max IDSD voltage IDSD-DV-1 Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: HIGHEST SELECTED Sensor Locations: N/A Alarm/Trip Setpoints: N/A Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 59 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-HSIIDS024-E5 Plant Spec Point

Description:

MIn IDSD voltage IDSD-DV-1 Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: Vdc ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 3 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 1 PER CELL How Processed: LOWEST SELECTED Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 60 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: DDS-BAP23-A1 Piant Spec Point

Description:

Containment Hydrogen Concentration Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States:  %

ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 20 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 3 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 1100 Aiarm/Trip Setpoints: HIGH(3%)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 61 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-RSA1R-L1 Plant Spec Point

Description:

Containment Sump Level RSA Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: In ENGR Units Conversion: N/A Minimum Instr Range: 7 Maximum Instr Range: 38 Zero Point

Reference:

CNTFLR Reference Point Notes: 5 IN ABOVE SUMP BOTTOM PROG or SENS: P Number of Sensors: 3 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11104, IN STILLING WELLS Alarm/Trip Setpoints: HIGH 2(20.6 IN)

Ni Detector Power Supply Cut-off N/A Power Level:

NI Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 62 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PMS-CNTP-RA-P6 Plant Spec Point

Description:

Narrow Range Ctmt Pressure Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: psig ENGR Units Conversion: N/A Minimum Instr Range: -5 Maximum Instr Range: 10 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 12452(PT005/7) ROOM 12341 (PT006/8)

Alarm/Trip Setpoints: LO (0.025 PSIG)LO 2(-0.8 PSIG) HI 1 (0.775 PSIG) HI 2(6.2 PSIG)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 63 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PMS-ERCP-RA-P6 Plant Spec Point

Description:

Extended Range Ctmnt Pressure Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: psig ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 240 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 3 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 12452(PT012/014) ROOM 12341 (PT013)

Alarm/Trip Setpoints: NONE Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 64 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PMS-CNTR-MX-R6 Plant Spec Point

Description:

High Range Containment Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: rad/h ENGR Units Conversion: N/A Minimum Instr Range: 1 Maximum Instr Range: 10000000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 4 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11500 185 ELV Alarm/Trip Setpoints: REFERENCE 6 N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 65 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: PMS-WRCL-RA-L6 Plant Spec Point

Description:

Containment WR Water Level Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States:  %

ENGR Units Conversion: 1% =.393 FT Minimum instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

COMPLX Reference Point Notes: BOTTOM OF REACTOR CAVITY PROG or SENS: P Number of Sensors: 3 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 11104,71.5 ELV Alarm/Trip Setpoints: HI(2%)HI2(3.3%) HI3(25.7%) HI4(67.9%) HI5(87.3%) HIS(94.4%)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 66 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: CL TEMP 3/C Point ID: RCS-TE125C2 Plant Spec Point

Description:

RCS WR Cold Leg IB Temperature Generic/Cond

Description:

Stm Gen 3(or C)Outlet Temperature Analog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum instr Range: 50 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: NONE Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 67 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: CL TEMP 4/D Point iD: RCS-TE125D2 Piant Spec Point

Description:

RCS WR Cold Leg 2B Temperature Generic/Cond

Description:

Stm Gen 4(or D)Outlet Temperature Analog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum Instr Range: 50 Maximum instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Aiarm/Trip Setpoints: NONE Ni Detector Power Supply Cut-off N/A Power Level:

NI Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 68 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: ML TEMP 1/A Point iD: RCS-TE135A Riant Spec Point

Description:

RCS WR Hot Leg 1 Temperature Generic/Cond

Description:

Stm Gen 1 (or A)iniet Temperature Analog/Digitai: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum instr Range: 50 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Aiarm/Trip Setpoints: HiGH (200 DEGF)

Ni Detector Power Suppiy Cut-off N/A Power Levei:

Ni Detector Power Suppiy Turn-on N/A Power Levei:

instrument Faiiure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 69 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: ML TEMP 2/B Point iD: RCS-TE135B Piant Spec Point

Description:

RCS WR Hot Leg 2 Temperature Generic/Cond

Description:

Stm Gen 2(or B)inlet Temperature Anaiog/Digitai: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum Instr Range: 50 Maximum instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Aiarm/Trip Setpoints: HIGH (200 DEGF)

Ni Detector Power Suppiy Cut-off N/A Power Levei:

NI Detector Power Suppiy Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 70 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: PMS-PCSL-RA-L6 Plant Spec Point

Description:

PCS Storage Tank Water Level Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States:  %

ENGR Units Conversion: 1% = .28 FT Minimum instr Range: 0 Maximum instr Range: 100 Zero Point

Reference:

SEALEV Reference Point Notes: 294.25 FT ABOVE TANK BOTTOM PROG or SENS: P Number of Sensors: 2 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 12701 Aiarm/Trip Setpoints: EMPTY(8.64%)

Ni Detector Power Supply Cut-off N/A Power Level:

NI Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 71 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: PMS-PCCF-SM-F6 Plant Spec Point

Description:

PCS Water Flow Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: gpm ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 660 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: N/A Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 72 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: RCS-TE161 Plant Spec Point

Description:

PRHR Outlet Heat Ex Temperature Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum Instr Range: 50 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: COLD TRAP DOWNSTREAM OF PRHR HX Alarm/Trip Setpoints: HIGH (220 DEGF)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 73 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: RMS-RY012 Plant Spec Point

Description:

Fuel Handling Area 1 Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: mrad/h ENGR Units Conversion: N/A Minimum instr Range; 0.1 Maximum Instr Range: 10000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: V Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 74 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: RMS-RY020 Piant Spec Point

Description:

Fuel Handling Area 2 Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: mrad/h ENGR Units Conversion: N/A Minimum instr Range: 0.1 Maximum Instr Range: 10000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: V Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 75 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: SFS-FT013A Plant Spec Point

Description:

SFS Pump A Discharge Flow Generlc/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: gpm ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1500 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: SFS DISCH LINE UPSTREAM OF SFS MX INLET NOZZLE Alarm/Trip Setpoints: LOW(700 GPM)LOW 2(600 GPM)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 76 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: SFS-FT013B Plant Spec Point

Description:

SFS Pump B Discharge Flow Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: gpm ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1500 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: SFS DISCH LINE UPSTREAM OF SFS MX INLET NOZZLE Alarm/Trip Setpoints: LOW (700 GPM)LOW 2(600 GPM)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 77 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: SFS-TE018 Riant Spec Point

Description:

Spent Fuel Pool Temperature Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum Instr Range: 50 Maximum instr Range: 250 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: NE CORNER OF SFP Aiarm/Trip Setpoints: HIGH (140 DEGF)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 78 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: SGS-RY026A Plant Spec Point

Description:

SG 1 Main Steam Line Noble Gas Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: uCI/cc ENGR Units Conversion: N/A Minimum Instr Range: 0.1 Maximum instr Range: 1000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: MAIN STEAM LINE Alarm/Trip Setpoints: HIGH (0.2 UCI/CC)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 79 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: SGS-RY027A Plant Spec Point

Description:

SG 2 Main Steam Line Noble Gas Generlc/Cond

Description:

NL Analog/Digital: A ENGR Unlts/DIg States: uCI/cc ENGR Units Conversion: N/A Minimum Instr Range: 0.1 Maximum Instr Range: 1000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: MAIN STEAM LINE Alarm/Trip Setpolnts: HIGH (0.2 UCI/CC)

Ni Detector Power Supply Cut-off N/A Power Level:

NI Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 80 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: Site Specific Piant Spec Point

Description:

Atmospheric Stabiiity Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States:  %

ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum instr Range: 100 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: N/A Ni Detector Power Suppiy Cut-off N/A Power Levei:

NI Detector Power Suppiy Turn-on N/A Power Levei:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 81 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: SV3-MES-100-A Plant Spec Point

Description:

60M Wind Speed Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: MPH ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 112 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 82 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: SV3-MES-101-A Plant Spec Point

Description:

60M Wind Direction Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: DEG ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 360 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: N/A Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 83 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: SV3-MES-100-B Plant Spec Point

Description:

60M Wind Speed Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States: MPH ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 112 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Aiarm/Trip Setpoints: N/A Ni Detector Power Supply Cut-off N/A Power Level:

NI Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 84 of 105

ND-21-0342 ERDS Data Point Library For Vogtie Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: SV3-MES-101-B Plant Spec Point

Description:

60M Wind Direction Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: DEG ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 360 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 85 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: SV3-MES-103-A Riant Spec Point

Description:

10M Wind Speed Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States: MPH ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum instr Range: 112 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Aiarm/Trip Setpoints: N/A Ni Detector Power Suppiy Cut-off N/A Power Levei:

Ni Detector Power Suppiy Turn-on N/A Power Levei:

instrument Faiiure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 86 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: SV3-MES-103-B Plant Spec Point

Description:

10M Wind Speed Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States: MPH ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 112 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Aiarm/Trip Setpoints: N/A Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 87 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: SV3-MES-104-A Plant Spec Point

Description:

10M Wind Direction Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: DEG ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 360 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 88 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: SV3-MES-104-B Riant Spec Point

Description:

10M Wind Direction Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States: DEG ENGR Units Conversion: N/A Minimum instr Range: 0 Maximum instr Range: 360 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: N/A How Processed: N/A Sensor Locations: N/A Aiarm/Trip Setpoints: N/A Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 89 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: SWS-RY008 Piant Spec Point

Description:

Service Water BD Radiation Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum Instr Range: 1e-07 Maximum instr Range: 0.01 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: SERVICE WATER SLOWDOWN LINE Aiarm/Trip Setpoints: HIGH (2.0E-007 UCi/CC)

Ni Detector Power Suppiy Cut-off N/A Power Level:

Ni Detector Power Suppiy Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 90 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: TDS-FT002 Plant Spec Point

Description:

Turbine Island Vent Exhaust Flow Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: scfm ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 6500 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: N/A Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 91 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: TDS-RY001 Piant Spec Point

Description:

Turbine Vent Discharge Radiation Generic/Cond

Description:

NL Anaiog/Digitai: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum instr Range: 1e-06 Maximum instr Range: 100000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: HIGH (8.0E-002 UCi/CC)

Ni Detector Power Suppiy Cut-off N/A Power Level:

Ni Detector Power Suppiy Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 92 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: VAS-RY001 Plant Spec Point

Description:

Fuel Handling Area Exhaust Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum Instr Range: 1e-06 Maximum Instr Range: 0.03 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: COMMON DUCT ON SUCT SIDE OF FHA EXH FANS 006A/B Alarm/Trip Setpoints: HIGH (4.0E-006 UCI/CC)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 93 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: CTMNT TEMP Point ID: VCS-TIY061 Plant Spec Point

Description:

Containment Volumetric Average Temperature Generic/Cond

Description:

Containment Temperature Analog/Digital: A ENGR Units/Dig States: DEGF ENGR Units Conversion: N/A Minimum Instr Range: 32 Maximum Instr Range: 422 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: P Number of Sensors: 8 How Processed: WEIGHTED AVERAGE Sensor Locations: N/A Alarm/Trip Setpoints: HIGH (71.3 DEGF)LOW (48.7 DEGF)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 94 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: VFS-FT105 Plant Spec Point

Description:

Plant Vent Flow Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: cfm ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 110000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: N/A Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 95 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: VFS-RY001 Piant Spec Point

Description:

Containment Exhaust Radiation Generic/Cond

Description:

NL Analog/Digitai: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum instr Range: 5e-07 Maximum Instr Range: 0.03 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: EXH TO PLANT VENT DUCT Aiarm/Trip Setpoints: HIGH (2.4E-002 UCI/CC)

Ni Detector Power Suppiy Cut-off N/A Power Levei:

Ni Detector Power Suppiy Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Levei Reference Leg: N/A Unique System

Description:

N/A Page 96 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: VFS-RY101 Plant Spec Point

Description:

Plant Vent Effluent Particle Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum instr Range: 1e-12 Maximum instr Range: 1e-07 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: EXH TO PLANT VENT DUCT Alarm/Trip Setpoints: HIGH (8.0E-008 UCI/CC)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 97 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: VFS-RY102 Plant Spec Point

Description:

Plant Vent iodine Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum Instr Range: 1e-11 Maximum instr Range: 1e-06 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: EXH TO PLANT VENT DUCT Alarm/Trip Setpoints: HIGH (8.0E-007 UCI/CC)

Ni Detector Power Supply Cut-off N/A Power Level:

NI Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 98 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: VFS-RY103 Piant Spec Point

Description:

Plant Vent Gas Normal Range Radiation Generic/Cond

Description:

NL Analog/Digitai: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum instr Range: 1e-07 Maximum instr Range: 0.01 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: EXH TO PLANT VENT DUCT Aiarm/Trip Setpoints: HIGH (8.0E-003 UCI/CC)

Ni Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 99 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: VFS-RY104A Plant Spec Point

Description:

Plant Vent Gas Mid Range Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum instr Range: 0.0001 Maximum instr Range: 100 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: EXH TO PLANT VENT DUCT Aiarm/Trip Setpoints: HIGH (8.0E001 UCI/CC)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 100 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: VFS-RY104B Plant Spec Point

Description:

Plant Vent Gas High Range Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum Instr Range: 0.1 Maximum Instr Range: 100000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: EXH TO PLANT VENT DUCT Aiarm/Trip Setpoints: HIGH (8.0E004 UCI/CC)

Nl Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 101 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: DDS-RSA41-L1 Plant Spec Point

Description:

Spent Fuel Pool Level RSA Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: ft ENGR Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 25.75 Zero Point

Reference:

SEALEV Reference Point Notes: AT ELV 109.5, 0.25 FT BELOW TOP SFP RACKS PROG or SENS: P Number of Sensors: 3 How Processed: BEST AVAILABLE PARAMETER Sensor Locations: ROOM 12365(019A/C) ROOM 12341 (019B)

Alarm/Trip Setpoints: LOW 2(23.5 FT)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 102 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: WGS-RY017 Plant Spec Point

Description:

Gaseous Radwaste Outlet Radiation Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum Instr Range: 0.0001 Maximum Instr Range: 100000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: N/A Alarm/Trip Setpoints: HIGH (2.5 UCI/CC)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

Instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 103 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtie 3 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: WLS-RY229 Piant Spec Point

Description:

Liquid Radwaste Effluent Radiation Generic/Cond

Description:

NL Analog/Digitai: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum instr Range: 1e-07 Maximum Instr Range: 0.1 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: WLS EFFLUENT DISCHARGE PATH Alarm/Trip Setpoints: HIGH (5.0E-005 UCI/CC)

Nl Detector Power Supply Cut-off N/A Power Level:

Ni Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 104 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date: 04/12/2021 Reactor Unit: Vogtle 3 Data Feeder: N/A NRC ERDS Parameter: NL Point iD: WWS-RY021 Plant Spec Point

Description:

Waste Water Channel Activity Generic/Cond

Description:

NL Analog/Digital: A ENGR Units/Dig States: uCi/cc ENGR Units Conversion: N/A Minimum Instr Range: 1e-07 Maximum instr Range: 0.1 Zero Point

Reference:

N/A Reference Point Notes: N/A PROG or SENS: S Number of Sensors: 1 How Processed: N/A Sensor Locations: WLS EFFLUENT DISCHARGE PATH Aiarm/Trip Setpoints: HIGH (2E-007 UCI/CC)

Nl Detector Power Supply Cut-off N/A Power Level:

Nl Detector Power Supply Turn-on N/A Power Level:

instrument Failure Mode: N/A Temperature Compensation For DP N Transmitters:

Level Reference Leg: N/A Unique System

Description:

N/A Page 105 of 105