Southern Nuclear Operating Company ND-21-0342 Emergency Response Data System (ERDS) Data Point Library For Vogtle Unit 3 (This Enclosure consists of 107 pages, not including this cover page)

ND-21-0342 Southern Nuclear Operating Company Emergency Response Data System

[ERDS]

Data Point Library For Vogtle Unit 3 April 12, 2021 NOTE:

Changes to the information presented herein may require NRG notification per 10 CFR 50, Appendix E, Section VI.

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 REFERENCES

1.

NUREG-1394, Rev. 1, "Emergency Response Data System (ERDS] Implementation"

2.

APP-DDS-J4-157, Rev. 2, "Data Display and Processing System Emergency Response Data System Datalink Interface Specification"

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

CORE FLOW Point iD:

DDS-FLC46-F0 Piant Spec Point

Description:

Total RCS Corrected Flow Rate Generic/Cond

Description:

Total Reactor Coolant Flow Analog/Digitai:

A ENGR Units/Dig States:

gpm ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

1000000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

8 How Processed:

COMPENSATED BASED ON REACTOR POWER Sensor Locations:

ROOM 11204 (101A/B/C/D) ROOM 11202 (102A/B/C/D)

Alarm/Trip Setpoints:

NONE FOR CORR. FLOW, INSTR LOW (95% OF FLOW)

Nl Detector Power Supply Cut-off Power Levei:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 1 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

RCS PRESSURE Point ID:

PMS-WRPR-RA-P6 Plant Spec Point

Description:

RCS Wide Range Pressure Generic/Cond

Description:

Reactor Coolant System Pressure Analog/Digital:

A ENGR Units/Dig States:

psig ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

3300 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

AVERAGE Sensor Locations:

ROOM 11400 (PT140A/C) ROOM 11306 (PT140B/D)

Alarm/Trip Setpoints:

LOW 2 (700 PSIG) LOW 3 (450 PSIG)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 2 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

BDS-RY010 Plant Spec Point

Description:

EDI Product Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum Instr Range:

1e-07 Maximum Instr Range:

0.01 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

ROOM 21380 Alarm/Trip Setpoints:

HIGH (2E-007 UCI/CC)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 3 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

BDS-RY011 Plant Spec Point

Description:

EDI Reject Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum Instr Range:

1e-07 Maximum Instr Range:

0.01 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

ROOM 21380 Alarm/Trip Setpoints:

HIGH (2E-007 UCI/CC)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 4 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

CVS-FT157A Plant Spec Point

Description:

Makeup Pump Disch Header HR Flow Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

gpm ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

175 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

ROOM 12255 Aiarm/Trip Setpoints:

NONE Ni Detector Power Suppiy Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 5 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

Ni SOURC RNG Point iD:

DDS-RSA39-N1 Riant Spec Point

Description:

Source Range Detector Generic/Cond

Description:

Nuclear Instruments, Source Range Anaiog/Digitai:

A ENGR Units/Dig States:

cps ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum instr Range:

1000000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

4 How Processed:

N/A Sensor Locations:

ROOM 11105 Alarm/Trip Setpoints:

5X BASE COUNT SETPOINT OR ALL CHANNELS 2X GREATER THAN CPS Nl Detector Power Suppiy Cut-off Power Levei:

N/A Ni Detector Power Suppiy Turn-on Power Levei:

N/A instrument Faiiure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 6 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

Nl POWER RNG Point ID:

DDS-RSA3J-J1 Plant Spec Point

Description:

Power Range Power (Compensated)

Generic/Cond

Description:

Nuclear Instruments, Power Range Analog/Digital:

A ENGR Units/Dig States:

power ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

160 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

8 How Processed:

N/A Sensor Locations:

ROOM 11105 Alarm/Trip Setpoints:

NONE Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 7 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PMS-TSAT-T1 Plant Spec Point

Description:

RCS Saturation Temperature Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum Instr Range:

212 Maximum Instr Range:

710 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpolnts:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 8 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

TEMP CORE EX Point iD:

PMS-CETC-TH-T6 Plant Spec Point

Description:

Fifth Hottest Core Exit Thermocouple Generic/Cond

Description:

Highest Temperature at the Core Exit Anaiog/Digitai:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum instr Range:

70 Maximum Instr Range:

2300 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

38 How Processed:

COMPARISON, 5TH HOTTEST SELECTED Sensor Locations:

ROOM 11105 Aiarm/Trip Setpoints:

NONE Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 9 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PMS-IRSL-RA-L6 Plant Spec Point

Description:

IRWST Water Level Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

ENGR Units Conversion:

1% =

.24FT Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

SEALEV Reference Point Notes:

5.5 FT ABOVE TANK BOTTOM PROG or SENS:

S Number of Sensors:

3 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

IRWST TANK Alarm/Trip Setpolnts:

LOW (97%)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

DRY Unique System

Description:

N/A Page 10 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

Nl INTER RNG Point ID:

PMS-NFLX-RA-N6 Plant Spec Point

Description:

Intermediate Range Neutron Flux Generic/Cond

Description:

Nuclear Instruments, Intermediate Range Analog/Digital:

A ENGR Units/Dig States:

ENGR Units Conversion:

N/A Minimum Instr Range:

1e-06 Maximum Instr Range:

200 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

4 How Processed:

N/A Sensor Locations:

ROOM 11105 Alarm/Trip Setpoints:

NONE Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 11 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PMS-PRHF-RA-F6 Plant Spec Point

Description:

PRHR Heat Exchanger Flow Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

gpm ENGR Units Conversion:

N/A Minimum Instr Range:

700 Maximum Instr Range:

3000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

2 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11300 Alarm/Trip Setpoints:

NONE Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 12 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

PRZR LEVEL Point ID:

PMS-PWLC-RA-L6 Plant Spec Point

Description:

Pressurizer Level Generic/Cond

Description:

Primary System Pressurizer Level Analog/Digital:

A ENGR Units/Dig States:

ENGR Units Conversion:

1% = 4.2293 IN Minimum instr Range:

0 Maximum instr Range:

100 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11400 (LT195A/C) ROOM 11306 (LT195B/D)

Alarm/Trip Setpoints:

COMPLICATED. BASED ON PLS/PMS LOGIC Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

WET Unique System

Description:

N/A Page 13 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

SUB MARGIN Point ID:

PMS-SCMG-T5 Plant Spec Point

Description:

RCS Subcooiing Margin Generic/Cond

Description:

Saturation Temperature Analog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

250 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 14 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

CVS-FT157B Riant Spec Point

Description:

Makeup Pump Disch Header LR Flow Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

gpm ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum Instr Range:

60 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

ROOM 12255 Aiarm/Trip Setpoints:

NONE Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 15 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

BWST LEVEL Point ID:

CVS-LT109 Plant Spec Point

Description:

Boric Acid Storage Tank Level Generic/Cond

Description:

Borated Water Storage Tank Level Analog/Digital:

A ENGR Units/Dig States:

ENGR Units Conversion:

1% = 1.8 IN Minimum instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

SEALEV Reference Point Notes:

BOTTOM OF TANK PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

BAST TANK, OUTSIDE OF SV3 TRUCK BAY Alarm/Trip Setpoints:

EMPTY (5%) LOW (93%) HIGH (97%)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

DRY Unique System

Description:

N/A Page 16 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PCS-LT040 Plant Spec Point

Description:

PCS Leak Chase Collection Pot Levei Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

ENGR Units Conversion:

1% = 0.28 IN Minimum instr Range:

0 Maximum instr Range:

100 Zero Point

Reference:

SEALEV Reference Point Notes:

0% = 2 IN, 100% = 30 IN PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

POT IN AUX BUILDING STAIRWELL S03 Aiarm/Trip Setpoints:

HIGH (50%)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 17 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PCS-TE024-SEL Plant Spec Point

Description:

PCS Air Flow Discharge Temp Select Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum Instr Range:

-40 Maximum Instr Range:

300 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

2 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ABOVE CNTMT IN AIR DISCH PATH ROOM 12541 Alarm/Trip Setpoints:

NONE Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 18 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PCS-TE036 Plant Spec Point

Description:

PCS Reclrculatlon Heater Inlet Temp Generlc/Cond

Description:

NL Analog/Digital:

A ENGR Unlts/DIg States:

DEGF ENGR Units Conversion:

N/A Minimum Instr Range:

25 Maximum Instr Range:

150 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

UPSTREAM OF THE PCS RECIRC HEATER IN ROOM 12306 Alarm/Trip Setpolnts:

LOW (47.25 DEGF)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 19 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PXS-TE064 Plant Spec Point

Description:

PRHR MX inlet High Point Temperature Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum Instr Range:

50 Maximum Instr Range:

650 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

TOP OF PRHR HX INLET LINE DOWNSTREAM OF V101 ROOM 11500 Alarm/Trip Setpoints:

LOW (428 DEGF) HIGH (563 DEGF)

Nl Detector Power Supply Gut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 20 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

ML LEVEL 1/A Point ID:

RCS-LT160A Plant Spec Point

Description:

RCS Hot Leg 1 Level Sensor Generic/Cond

Description:

Hot Leg 1 (or A) Water Level Analog/Digital:

A ENGR Units/Dig States:

span ENGR Units Conversion:

1% =

0.31 IN Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

SEALEV Reference Point Notes:

BOTTOM OF HL PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

ROOM 11204, Alarm/Trip Setpoints:

LOW 1 (64.5%) LOW 3 (16.1%)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

WET Unique System

Description:

N/A Page 21 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

ML LEVEL 2/B Point ID:

RCS-LT160B Plant Spec Point

Description:

RCS Hot Leg 2 Level Sensor Generic/Cond

Description:

Hot Leg 2 (or B) Water Level Analog/Digital:

A ENGR Units/Dig States:

span ENGR Units Conversion:

1% =

0.31 IN Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

SEALEV Reference Point Notes:

BOTTOM OF HL PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

ROOM 11202, UPSTREAM OF RNS CONNECTION Alarm/Trip Setpoints:

LOW 1 (64.5%) LOW 3 (16.1%)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

WET Unique System

Description:

N/A Page 22 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

CL TEMP 1/A Point iD:

RCS-TE125A2 Piant Spec Point

Description:

RCS Wide Range Coid Leg 1A Temperature Generic/Cond

Description:

Stm Gen 1 (or A) Outiet Temperature Analog/Digitai:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum instr Range:

50 Maximum instr Range:

700 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

ROOM 11201, INSIDE COLD LEG 1A Aiarm/Trip Setpoints:

NONE Ni Detector Power Suppiy Cut-off Power Levei:

N/A Ni Detector Power Supply Turn-on Power Levei:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 23 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

CL TEMP 2/B Point iD:

RCS-TE125B2 Piant Spec Point

Description:

RCS Wide Range Cold Leg 2A Temperature Generic/Cond

Description:

Stm Gen 2 (or B) Outlet Temperature Analog/Digitai:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum instr Range:

50 Maximum instr Range:

700 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

ROOM 11202, INSIDE COLD LEG 2A Alarm/Trip Setpoints:

NONE Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 24 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

PMS-ADS1-AC Piant Spec Point

Description:

ADS Stage 1 Actuation Generic/Cond

Description:

NL Anaiog/Digital:

D ENGR Units/Dig States:

Digital ENGR Units Conversion:

N/A Minimum instr Range:

0=NORMAL Maximum instr Range:

1=ACT Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

2 OUT OF 4 VOTING LOGIC Sensor Locations:

ROOM 11703 185 ELV (V001A) ROOM 11603 160.5 ELV (V001B)

Aiarm/Trip Setpoints:

NONE Ni Detector Power Suppiy Cut-off Power Level:

N/A Ni Detector Power Suppiy Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 25 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PMS-ADS2-AC Plant Spec Point

Description:

ADS Stage 2 Actuation Generic/Cond

Description:

NL Analog/Digital:

D ENGR Units/Dig States:

Digital ENGR Units Conversion:

N/A Minimum Instr Range:

0=NORMAL Maximum Instr Range:

1=ACT Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

2 OUT OF 4 VOTING LOGIC Sensor Locations:

ROOM 11703 185 ELV (V002A) ROOM 11603 160.5 ELV (V002B)

Alarm/Trip Setpoints:

NONE Ni Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 26 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PMS-ADS3-AC Plant Spec Point

Description:

ADS Stage 3 Actuation Generlc/Cond

Description:

NL Analog/Digital:

D ENGR Unlts/DIg States:

Digital ENGR Units Conversion:

N/A Minimum Instr Range:

0=NORMAL Maximum Instr Range:

1=ACT Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

2 OUT OF 4 VOTING LOGIC Sensor Locations:

ROOM 11703 185 ELV (V003A) ROOM 11603 160.5 ELV (V003B)

Alarm/Trip Setpolnts:

NONE Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 27 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PMS-ADS4-AC Plant Spec Point

Description:

ADS Stage 4 Actuation Generic/Cond

Description:

NL Analog/Digital:

D ENGR Units/Dig States:

Digital ENGR Units Conversion:

N/A Minimum Instr Range:

0=NORMAL Maximum Instr Range:

1=ACT Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

2 OUT OF 4 VOTING LOGIC Sensor Locations:

ROOM 11301 ELV 118.5 (V004A/C) ROOM 11302 ELV 118.5 (V004B/D)

Alarm/Trip Setpoints:

NONE Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 28 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-RSA45-T1 Piant Spec Point

Description:

IRWST Surface Temperature RSA Generic/Cond

Description:

NL Anaiog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum instr Range:

50 Maximum instr Range:

300 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

2 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11305 Aiarm/Trip Setpoints:

HIGH (110 DEGF)

Ni Detector Power Suppiy Cut-off Power Level:

N/A NI Detector Power Suppiy Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 29 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-RSA47-T1 Riant Spec Point

Description:

IRWST Bottom Temperature RSA Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum instr Range:

50 Maximum Instr Range:

300 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

2 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11305 Alarm/Trip Setpoints:

HIGH (110 DEGF)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 30 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-RSA59-P1 Plant Spec Point

Description:

Accumulator Tank A Pressure RSA Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

psig ENGR Units Conversion:

N/A Minimum Instr Range:

100 Maximum Instr Range:

800 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

2 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11206 Alarm/Trip Setpolnts:

LOW (662 PSIG) HI (744 PSIG)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N/A Level Reference Leg:

N/A Unique System

Description:

N/A Page 31 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-RSA61-P1 Piant Spec Point

Description:

Accumulator Tank B Pressure RSA Generic/Cond

Description:

NL Anaiog/Digital:

A ENGR Units/Dig States:

psig ENGR Units Conversion:

N/A Minimum instr Range:

100 Maximum Instr Range:

800 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

2 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11207 Aiarm/Trip Setpoints:

LOW (662 PSIG) Hi (744 PSIG)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N/A Level Reference Leg:

N/A Unique System

Description:

N/A Page 32 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-RSA67-L1 Piant Spec Point

Description:

CMT A Narrow Range Upper Levei RSA Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

span ENGR Units Conversion:

1% = 0.2 IN Minimum Instr Range:

0 Maximum instr Range:

100 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11400 Aiarm/Trip Setpoints:

LOW (DEP) LOW 2 (69.4%) LOW 3 (DEP)

Ni Detector Power Suppiy Cut-off Power Levei:

N/A NI Detector Power Suppiy Turn-on Power Levei:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 33 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-RSA71-L1 Piant Spec Point

Description:

CMT B Narrow Range Upper Levei RSA Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

span ENGR Units Conversion:

1% = 0.2 iN Minimum instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAiLABLE PARAMETER Sensor Locations:

ROOM 11400 Aiarm/Trip Setpoints:

LOW (DEP) LOW 2 (69.4%) LOW 3 (DEP)

Ni Detector Power Suppiy Cut-off Power Levei:

N/A Ni Detector Power Suppiy Turn-on Power Levei:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 34 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-RSA69-L1 Piant Spec Point

Description:

CMT A Narrow Range Lower Level RSA Generic/Cond

Description:

NL Analog/Digitai:

A ENGR Units/Dig States:

span ENGR Units Conversion:

1% = 0.379 IN Minimum instr Range:

0 Maximum instr Range:

100 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11400 Alarm/Trip Setpoints:

LOW 4 (91%) LOW 5 (73.5%) LOW 6 (DEP)

Nl Detector Power Suppiy Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 35 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-RSA73-L1 Riant Spec Point

Description:

CMT B Narrow Range Lower Level RSA Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

span ENGR Units Conversion:

1% = 0.379 IN Minimum instr Range:

0 Maximum instr Range:

100 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11400 Aiarm/Trip Setpoints:

LOW 4 (91%) LOW 5 (73.5%) LOW 6 (DEP)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 36 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-RSA1F-T1 Riant Spec Point

Description:

CMT A Top Temperature RSA Generic/Cond

Description:

NL Analog/Digitai:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum Instr Range:

50 Maximum instr Range:

600 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

2 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11400 Aiarm/Trip Setpoints:

Hi (107.5 DEG F)

Ni Detector Power Suppiy Cut-off Power Levei:

N/A NI Detector Power Suppiy Turn-on Power Levei:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 37 of 105

ND-21-0342 ERDS Data Point Library For Vogtie Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-RSA1L-L1 Plant Spec Point

Description:

CMT B Top Temperature RSA Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum instr Range:

50 Maximum instr Range:

600 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

2 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11400 Alarm/Trip Setpoints:

Hi (107.5 DEG F)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 38 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

MN FD FL 1/A Point iD:

DDS-RSA17-F1 Piant Spec Point

Description:

SGI Hi Rng MFW Fiow RSA (Unc)

Generic/Cond

Description:

Stm Gen 1 (or A) Main Feedwater Fiow Analog/Digitai:

A ENGR Units/Dig States:

ibm/h ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum instr Range:

9000000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

3 How Processed:

BEST AVAiLABLE PARAMETER Sensor Locations:

ROOM 20400 Aiarm/Trip Setpoints:

COMPLiCATED. BASED ON MULTiPLE CHANNELS Nl Detector Power Suppiy Cut-off Power Levei:

N/A Ni Detector Power Suppiy Turn-on Power Levei:

N/A instrument Faiiure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 39 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

MN FD FL 2/B Point ID:

DDS-RSA21-F1 Piant Spec Point

Description:

SG2 Hi Rng MFW Flow RSA (Unc)

Generic/Cond

Description:

Stm Gen 2 (or B) Main Feedwater Flow Anaiog/Digital:

A ENGR Units/Dig States:

Ibm/h ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

9000000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

3 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 20400 Aiarm/Trip Setpoints:

COMPLICATED. BASED ON MULTIPLE CHANNELS Ni Detector Power Suppiy Cut-off Power Levei:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 40 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

SG PRESS 1/A Point ID:

DDS-RSA91-P1 Plant Spec Point

Description:

SGI Steam Line Pressure RSA Generic/Cond

Description:

Steam Generator 1 (or A)

Pressure Analog/Digital:

A ENGR Units/Dig States:

psig ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum instr Range:

1300 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 1100, ROOM 12405 Alarm/Trip Setpoints:

LOW (620 PSIG)

Ni Detector Power Supply Gut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 41 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

SG PRESS 2/B Point ID:

DDS-RSA93-P1 Plant Spec Point

Description:

SG2 Steam Line Pressure RSA Generlc/Cond

Description:

Steam Generator 2 (or B) Pressure Analog/Digital:

A ENGR Unlts/DIg States:

psig ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

1300 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 1100, ROOM 12406 Alarm/Trip Setpolnts:

LOW (620 PSIG)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 42 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

SG LEVEL 1/A Point ID:

PMS-S1NL-RA-L6 Plant Spec Point

Description:

Compensated NR SGI Water Level Generic/Cond

Description:

Steam Generator 1 (or A) Water Level Analog/Digital:

A ENGR Units/Dig States:

span ENGR Units Conversion:

1% =

2.5331 IN Minimum instr Range:

0 Maximum instr Range:

100 Zero Point

Reference:

TUBSHT Reference Point Notes:

383.64 IN ABOVE TUBE SHEET PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 1100 Alarm/Trip Setpoints:

LOW (26%) LOW 2 (21%) Hi (72.8%) Hi 2 (77%) Hi 3 (82%)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

WET Unique System

Description:

N/A Page 43 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

SG LEVEL 2/B Point ID:

PMS-S2NL-RA-L6 Riant Spec Point

Description:

Compensated NR SG2 Water Level Generic/Cond

Description:

Steam Generator 2 (or B) Water Level Anaiog/Digitai:

A ENGR Units/Dig States:

span ENGR Units Conversion:

1% =

2.5331 IN Minimum instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

TUBSHT Reference Point Notes:

383.64 IN ABOVE TUBE SHEET PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 1100 Alarm/Trip Setpoints:

LOW (26%) LOW 2 (21%) Hi (72.8%) Hi 2 (77%) Hi 3 (82%)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

WET Unique System

Description:

N/A Page 44 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

SG LEVEL 1/A Point iD:

PMS-S1WL-RA-L6 Plant Spec Point

Description:

Compensated WR SGI Water Level Generic/Cond

Description:

Steam Generator 1 (or A) Water Level Anaiog/Digitai:

A ENGR Units/Dig States:

span ENGR Units Conversion:

1% =

6.2681 IN Minimum instr Range:

0 Maximum instr Range:

100 Zero Point

Reference:

TUBSHT Reference Point Notes:

10.14 IN ABOVE TUBE SHEET PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 1100 Alarm/Trip Setpoints:

LOW (40%) LOW 2 (35%) HI (95%)

Nl Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

WET Unique System

Description:

N/A Page 45 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

SG LEVEL 2/B Point ID:

PMS-S2WL-RA-L6 Plant Spec Point

Description:

Compensated WR SG2 Water Level Generic/Cond

Description:

Steam Generator 2 (or B) Water Level Analog/Digital:

A ENGR Units/Dig States:

span ENGR Units Conversion:

1% =

6.2681 IN Minimum instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

TUBSHT Reference Point Notes:

10.14 IN ABOVE TUBE SHEET PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 1100 Aiarm/Trip Setpoints:

LOW (40%) LOW 2 (35%) HI (95%)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

WET Unique System

Description:

N/A Page 46 of 105

ND-21-0342 ERDS Data Point Library For Vogtie Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

AX FD FL 1/A Point ID:

PMS-S1SF-RA-F6 Plant Spec Point

Description:

SGI Startup Feedwater Flow Generic/Cond

Description:

Stm Gen 1 (or A) Auxiliary FW Flow Analog/Digital:

A ENGR Units/Dig States:

gpm ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

600 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

5 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 12211 Alarm/Trip Setpoints:

LOW (210 GPM) LOW 2 (200 GPM)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 47 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

AX FD FL 2/B Point iD:

PMS-S2SF-RA-F6 Piant Spec Point

Description:

SG2 Startup Feedwater Flow Generic/Cond

Description:

Stm Gen 2 (or B) Auxiliary FW Flow Anaiog/Digitai:

A ENGR Units/Dig States:

gpm ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

600 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

5 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 12211 Aiarm/Trip Setpoints:

LOW (210 GPM) LOW 2 (200 GPM)

Ni Detector Power Suppiy Cut-off Power Levei:

N/A Ni Detector Power Suppiy Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 48 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-HSilDS004-E1 Riant Spec Point

Description:

Max IDSA voltage IDSA-DV-1 Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

HIGHEST SELECTED Sensor Locations:

N/A Aiarm/Trip Setpoints:

N/A Ni Detector Power Suppiy Cut-off Power Levei:

N/A Ni Detector Power Suppiy Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 49 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-HSIiDS004-E5 Plant Spec Point

Description:

Min IDSA voltage IDSA-DV-1 Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum Instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

LOWEST SELECTED Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 50 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-HSIIDS008-E1 Plant Spec Point

Description:

Max IDSB voltage IDSB-DV-1 Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

HIGHEST SELECTED Sensor Locations:

N/A Alarm/Trip Setpolnts:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 51 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-HSIIDS008-E5 Plant Spec Point

Description:

Min IDSB voltage IDSB-DV-1 Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

LOWEST SELECTED Sensor Locations:

N/A Alarm/T rip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 52 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-HSiiDS012-E1 Plant Spec Point

Description:

Max IDSB voltage IDSB-DV-2 Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

HIGHEST SELECTED Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Nl Detector Power Supply Gut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 53 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-HSIiDS012-E5 Plant Spec Point

Description:

Min IDSB voltage iDSB-DV-2 Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

LOWEST SELECTED Sensor Locations:

N/A Aiarm/Trip Setpoints:

N/A Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 54 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-HSIiDS016-E1 Piant Spec Point

Description:

Max IDSC voltage iDSC-DV-1 Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum Instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

HIGHEST SELECTED Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 55 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-HSilDS016-E5 Plant Spec Point

Description:

Min iDSC voitage iDSC-DV-1 Generic/Cond

Description:

NL Analog/Digitai:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

LOWEST SELECTED Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 56 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-HSIIDS020-E1 Plant Spec Point

Description:

Max IDSC voltage IDSC-DV-2 Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

HIGHEST SELECTED Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 57 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-HSIIDS020-E5 Plant Spec Point

Description:

Min IDSC voltage IDSC-DV-2 Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

LOWEST SELECTED Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 58 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-HSIiDS024-E1 Plant Spec Point

Description:

Max IDSD voltage IDSD-DV-1 Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

HIGHEST SELECTED Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 59 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-HSIIDS024-E5 Plant Spec Point

Description:

MIn IDSD voltage IDSD-DV-1 Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

Vdc ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

1 PER CELL How Processed:

LOWEST SELECTED Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 60 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

DDS-BAP23-A1 Piant Spec Point

Description:

Containment Hydrogen Concentration Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

20 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

3 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 1100 Aiarm/Trip Setpoints:

HIGH (3%)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 61 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-RSA1R-L1 Plant Spec Point

Description:

Containment Sump Level RSA Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

In ENGR Units Conversion:

N/A Minimum Instr Range:

7 Maximum Instr Range:

38 Zero Point

Reference:

CNTFLR Reference Point Notes:

5 IN ABOVE SUMP BOTTOM PROG or SENS:

P Number of Sensors:

3 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11104, IN STILLING WELLS Alarm/Trip Setpoints:

HIGH 2 (20.6 IN)

Ni Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 62 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PMS-CNTP-RA-P6 Plant Spec Point

Description:

Narrow Range Ctmt Pressure Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

psig ENGR Units Conversion:

N/A Minimum Instr Range:

-5 Maximum Instr Range:

10 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 12452 (PT005/7) ROOM 12341 (PT006/8)

Alarm/Trip Setpoints:

LO (0.025 PSIG) LO 2

(-0.8 PSIG) HI 1 (0.775 PSIG) HI 2 (6.2 PSIG)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 63 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PMS-ERCP-RA-P6 Plant Spec Point

Description:

Extended Range Ctmnt Pressure Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

psig ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

240 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

3 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 12452 (PT012/014) ROOM 12341 (PT013)

Alarm/Trip Setpoints:

NONE Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 64 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PMS-CNTR-MX-R6 Plant Spec Point

Description:

High Range Containment Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

rad/h ENGR Units Conversion:

N/A Minimum Instr Range:

1 Maximum Instr Range:

10000000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

4 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11500 185 ELV Alarm/Trip Setpoints:

REFERENCE 6 N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 65 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

PMS-WRCL-RA-L6 Plant Spec Point

Description:

Containment WR Water Level Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

ENGR Units Conversion:

1% =

.393 FT Minimum instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

COMPLX Reference Point Notes:

BOTTOM OF REACTOR CAVITY PROG or SENS:

P Number of Sensors:

3 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 11104,71.5 ELV Alarm/Trip Setpoints:

HI (2%) HI2 (3.3%) HI3 (25.7%) HI4 (67.9%) HI5 (87.3%) HIS (94.4%)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 66 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

CL TEMP 3/C Point ID:

RCS-TE125C2 Plant Spec Point

Description:

RCS WR Cold Leg IB Temperature Generic/Cond

Description:

Stm Gen 3 (or C) Outlet Temperature Analog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum instr Range:

50 Maximum Instr Range:

700 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

NONE Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 67 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

CL TEMP 4/D Point iD:

RCS-TE125D2 Piant Spec Point

Description:

RCS WR Cold Leg 2B Temperature Generic/Cond

Description:

Stm Gen 4 (or D) Outlet Temperature Analog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum Instr Range:

50 Maximum instr Range:

700 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Aiarm/Trip Setpoints:

NONE Ni Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 68 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

ML TEMP 1/A Point iD:

RCS-TE135A Riant Spec Point

Description:

RCS WR Hot Leg 1 Temperature Generic/Cond

Description:

Stm Gen 1 (or A) iniet Temperature Analog/Digitai:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum instr Range:

50 Maximum Instr Range:

700 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Aiarm/Trip Setpoints:

HiGH (200 DEGF)

Ni Detector Power Suppiy Cut-off Power Levei:

N/A Ni Detector Power Suppiy Turn-on Power Levei:

N/A instrument Faiiure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 69 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

ML TEMP 2/B Point iD:

RCS-TE135B Piant Spec Point

Description:

RCS WR Hot Leg 2 Temperature Generic/Cond

Description:

Stm Gen 2 (or B) inlet Temperature Anaiog/Digitai:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum Instr Range:

50 Maximum instr Range:

700 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Aiarm/Trip Setpoints:

HIGH (200 DEGF)

Ni Detector Power Suppiy Cut-off Power Levei:

N/A NI Detector Power Suppiy Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 70 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

PMS-PCSL-RA-L6 Plant Spec Point

Description:

PCS Storage Tank Water Level Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

ENGR Units Conversion:

1% =

.28 FT Minimum instr Range:

0 Maximum instr Range:

100 Zero Point

Reference:

SEALEV Reference Point Notes:

294.25 FT ABOVE TANK BOTTOM PROG or SENS:

P Number of Sensors:

2 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 12701 Aiarm/Trip Setpoints:

EMPTY (8.64%)

Ni Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 71 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

PMS-PCCF-SM-F6 Plant Spec Point

Description:

PCS Water Flow Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

gpm ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

660 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

N/A Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Alarm/T rip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 72 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

RCS-TE161 Plant Spec Point

Description:

PRHR Outlet Heat Ex Temperature Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum Instr Range:

50 Maximum Instr Range:

700 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

COLD TRAP DOWNSTREAM OF PRHR HX Alarm/Trip Setpoints:

HIGH (220 DEGF)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 73 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

RMS-RY012 Plant Spec Point

Description:

Fuel Handling Area 1 Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

mrad/h ENGR Units Conversion:

N/A Minimum instr Range; 0.1 Maximum Instr Range:

10000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

V Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 74 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

RMS-RY020 Piant Spec Point

Description:

Fuel Handling Area 2 Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

mrad/h ENGR Units Conversion:

N/A Minimum instr Range:

0.1 Maximum Instr Range:

10000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

V Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 75 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

SFS-FT013A Plant Spec Point

Description:

SFS Pump A Discharge Flow Generlc/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

gpm ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

1500 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

SFS DISCH LINE UPSTREAM OF SFS MX INLET NOZZLE Alarm/Trip Setpoints:

LOW (700 GPM) LOW 2 (600 GPM)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 76 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

SFS-FT013B Plant Spec Point

Description:

SFS Pump B Discharge Flow Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

gpm ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

1500 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

SFS DISCH LINE UPSTREAM OF SFS MX INLET NOZZLE Alarm/Trip Setpoints:

LOW (700 GPM) LOW 2 (600 GPM)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 77 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

SFS-TE018 Riant Spec Point

Description:

Spent Fuel Pool Temperature Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum Instr Range:

50 Maximum instr Range:

250 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

NE CORNER OF SFP Aiarm/Trip Setpoints:

HIGH (140 DEGF)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 78 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

SGS-RY026A Plant Spec Point

Description:

SG 1 Main Steam Line Noble Gas Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

uCI/cc ENGR Units Conversion:

N/A Minimum Instr Range:

0.1 Maximum instr Range:

1000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

MAIN STEAM LINE Alarm/Trip Setpoints:

HIGH (0.2 UCI/CC)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 79 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

SGS-RY027A Plant Spec Point

Description:

SG 2 Main Steam Line Noble Gas Generlc/Cond

Description:

NL Analog/Digital:

A ENGR Unlts/DIg States:

uCI/cc ENGR Units Conversion:

N/A Minimum Instr Range:

0.1 Maximum Instr Range:

1000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

MAIN STEAM LINE Alarm/Trip Setpolnts:

HIGH (0.2 UCI/CC)

Ni Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 80 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

Site Specific Piant Spec Point

Description:

Atmospheric Stabiiity Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum instr Range:

100 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Ni Detector Power Suppiy Cut-off Power Levei:

N/A NI Detector Power Suppiy Turn-on Power Levei:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 81 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

SV3-MES-100-A Plant Spec Point

Description:

60M Wind Speed Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

MPH ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

112 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 82 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

SV3-MES-101-A Plant Spec Point

Description:

60M Wind Direction Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

DEG ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

360 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 83 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

SV3-MES-100-B Plant Spec Point

Description:

60M Wind Speed Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

MPH ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

112 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Aiarm/Trip Setpoints:

N/A Ni Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 84 of 105

ND-21-0342 ERDS Data Point Library For Vogtie Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

SV3-MES-101-B Plant Spec Point

Description:

60M Wind Direction Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

DEG ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

360 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 85 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

SV3-MES-103-A Riant Spec Point

Description:

10M Wind Speed Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

MPH ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum instr Range:

112 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Aiarm/Trip Setpoints:

N/A Ni Detector Power Suppiy Cut-off Power Levei:

N/A Ni Detector Power Suppiy Turn-on Power Levei:

N/A instrument Faiiure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 86 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

SV3-MES-103-B Plant Spec Point

Description:

10M Wind Speed Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

MPH ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

112 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Aiarm/Trip Setpoints:

N/A Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 87 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

SV3-MES-104-A Plant Spec Point

Description:

10M Wind Direction Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

DEG ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

360 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 88 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

SV3-MES-104-B Riant Spec Point

Description:

10M Wind Direction Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

DEG ENGR Units Conversion:

N/A Minimum instr Range:

0 Maximum instr Range:

360 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

N/A How Processed:

N/A Sensor Locations:

N/A Aiarm/Trip Setpoints:

N/A Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 89 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

SWS-RY008 Piant Spec Point

Description:

Service Water BD Radiation Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum Instr Range:

1e-07 Maximum instr Range:

0.01 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

SERVICE WATER SLOWDOWN LINE Aiarm/Trip Setpoints:

HIGH (2.0E-007 UCi/CC)

Ni Detector Power Suppiy Cut-off Power Level:

N/A Ni Detector Power Suppiy Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 90 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

TDS-FT002 Plant Spec Point

Description:

Turbine Island Vent Exhaust Flow Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

scfm ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

6500 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 91 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

TDS-RY001 Piant Spec Point

Description:

Turbine Vent Discharge Radiation Generic/Cond

Description:

NL Anaiog/Digitai:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum instr Range:

1e-06 Maximum instr Range:

100000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

HIGH (8.0E-002 UCi/CC)

Ni Detector Power Suppiy Cut-off Power Level:

N/A Ni Detector Power Suppiy Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 92 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

VAS-RY001 Plant Spec Point

Description:

Fuel Handling Area Exhaust Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum Instr Range:

1e-06 Maximum Instr Range:

0.03 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

COMMON DUCT ON SUCT SIDE OF FHA EXH FANS 006A/B Alarm/Trip Setpoints:

HIGH (4.0E-006 UCI/CC)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 93 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

CTMNT TEMP Point ID:

VCS-TIY061 Plant Spec Point

Description:

Containment Volumetric Average Temperature Generic/Cond

Description:

Containment Temperature Analog/Digital:

A ENGR Units/Dig States:

DEGF ENGR Units Conversion:

N/A Minimum Instr Range:

32 Maximum Instr Range:

422 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

P Number of Sensors:

8 How Processed:

WEIGHTED AVERAGE Sensor Locations:

N/A Alarm/Trip Setpoints:

HIGH (71.3 DEGF) LOW (48.7 DEGF)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 94 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

VFS-FT105 Plant Spec Point

Description:

Plant Vent Flow Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

cfm ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

110000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

N/A Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 95 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

VFS-RY001 Piant Spec Point

Description:

Containment Exhaust Radiation Generic/Cond

Description:

NL Analog/Digitai:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum instr Range:

5e-07 Maximum Instr Range:

0.03 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

EXH TO PLANT VENT DUCT Aiarm/Trip Setpoints:

HIGH (2.4E-002 UCI/CC)

Ni Detector Power Suppiy Cut-off Power Levei:

N/A Ni Detector Power Suppiy Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Levei Reference Leg:

N/A Unique System

Description:

N/A Page 96 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

VFS-RY101 Plant Spec Point

Description:

Plant Vent Effluent Particle Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum instr Range:

1e-12 Maximum instr Range:

1e-07 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

EXH TO PLANT VENT DUCT Alarm/Trip Setpoints:

HIGH (8.0E-008 UCI/CC)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 97 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

VFS-RY102 Plant Spec Point

Description:

Plant Vent iodine Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum Instr Range:

1e-11 Maximum instr Range:

1e-06 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

EXH TO PLANT VENT DUCT Alarm/Trip Setpoints:

HIGH (8.0E-007 UCI/CC)

Ni Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 98 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

VFS-RY103 Piant Spec Point

Description:

Plant Vent Gas Normal Range Radiation Generic/Cond

Description:

NL Analog/Digitai:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum instr Range:

1e-07 Maximum instr Range:

0.01 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

EXH TO PLANT VENT DUCT Aiarm/Trip Setpoints:

HIGH (8.0E-003 UCI/CC)

Ni Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 99 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

VFS-RY104A Plant Spec Point

Description:

Plant Vent Gas Mid Range Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum instr Range:

0.0001 Maximum instr Range:

100 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

EXH TO PLANT VENT DUCT Aiarm/T rip Setpoints:

HIGH (8.0E001 UCI/CC)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 100 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

VFS-RY104B Plant Spec Point

Description:

Plant Vent Gas High Range Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum Instr Range:

0.1 Maximum Instr Range:

100000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

EXH TO PLANT VENT DUCT Aiarm/Trip Setpoints:

HIGH (8.0E004 UCI/CC)

Nl Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 101 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

DDS-RSA41-L1 Plant Spec Point

Description:

Spent Fuel Pool Level RSA Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

ft ENGR Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

25.75 Zero Point

Reference:

SEALEV Reference Point Notes:

AT ELV 109.5, 0.25 FT BELOW TOP SFP RACKS PROG or SENS:

P Number of Sensors:

3 How Processed:

BEST AVAILABLE PARAMETER Sensor Locations:

ROOM 12365 (019A/C) ROOM 12341 (019B)

Alarm/Trip Setpoints:

LOW 2 (23.5 FT)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 102 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

WGS-RY017 Plant Spec Point

Description:

Gaseous Radwaste Outlet Radiation Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum Instr Range:

0.0001 Maximum Instr Range:

100000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

N/A Alarm/Trip Setpoints:

HIGH (2.5 UCI/CC)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 103 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtie 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

WLS-RY229 Piant Spec Point

Description:

Liquid Radwaste Effluent Radiation Generic/Cond

Description:

NL Analog/Digitai:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum instr Range:

1e-07 Maximum Instr Range:

0.1 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

WLS EFFLUENT DISCHARGE PATH Alarm/Trip Setpoints:

HIGH (5.0E-005 UCI/CC)

Nl Detector Power Supply Cut-off Power Level:

N/A Ni Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 104 of 105

ND-21-0342 ERDS Data Point Library For Vogtle Unit 3 Date:

04/12/2021 Reactor Unit:

Vogtle 3 Data Feeder:

N/A NRC ERDS Parameter:

NL Point iD:

WWS-RY021 Plant Spec Point

Description:

Waste Water Channel Activity Generic/Cond

Description:

NL Analog/Digital:

A ENGR Units/Dig States:

uCi/cc ENGR Units Conversion:

N/A Minimum Instr Range:

1e-07 Maximum instr Range:

0.1 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROG or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

WLS EFFLUENT DISCHARGE PATH Aiarm/Trip Setpoints:

HIGH (2E-007 UCI/CC)

Nl Detector Power Supply Cut-off Power Level:

N/A Nl Detector Power Supply Turn-on Power Level:

N/A instrument Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N Level Reference Leg:

N/A Unique System

Description:

N/A Page 105 of 105