Letter Sequence Other |
|---|
EPID:L-2020-TOP-0038, August 18-20, 2020 Regulatory Audit Plan for Errata to Framatome Inc. Topical Report BAW-10241PA, Revision 1, Bhtp DNB Correlation Applied with Lynxt Topical Report (Open) |
|
MONTHYEARML20211L7442020-08-0404 August 2020 Audit Plan for Errata to Framatome Topical Report BAW-10241PA, Revision 1, Bhtp DNB Correlation Applied Lynxt Topical Report Project No. 728 Project stage: Other ML20211L7472020-08-0404 August 2020 August 18-20, 2020 Regulatory Audit Plan for Errata to Framatome Inc. Topical Report BAW-10241PA, Revision 1, Bhtp DNB Correlation Applied with Lynxt Topical Report Project stage: Request ML20211L7302020-08-0404 August 2020 August 18-20, 2020 Regulatory Audit Plan Letter for Errata to Framatome Inc. Topical Report BAW-10241PA, Revision 1, Bhtp DNB Correlation Applied with Lynxt Topical Report Project stage: Other ML20259A2932020-09-17017 September 2020 Final Safety Evaluation Letter for Errata to Framatome TR BAW-10241PA-Revision 1, Bht DNB Correlation Applied with Lynxt Topical Report Project stage: Approval ML20259A2472020-09-17017 September 2020 Framatome Response to Draft Safety Evaluation for Errata to TR BAW-10241PA, Revision 1, Bhtp DNB Correlation Project stage: Draft Other ML20335A0052020-12-0101 December 2020 Letter, Audit Report August 18 - 20, 2020 Regulatory Audit Plan for Errata to Framatome Inc. Topical Report BAW-10241PA, Rev. 1, Bhtp DNB Correlation Applied with Lynxt Topical Report Project stage: Other ML20335A0062020-12-0101 December 2020 Audit Report August 18 - 20, 2020 Regulatory Audit Plan for Errata to Framatome Inc. Topical Report Baw-10241pa, Revision 1, Bhtp Dnb Correlation Applied with Lynxt Topical Report; (EPID L-2020-TOP-0038 Project stage: Other ML21015A1432021-02-0202 February 2021 Verification of Accepted Proprietary and Non-Proprietary Versions of Framatome Topical Report BAW-10241P-A, Revision 2, Bhtp DNB Correlation Applied with Lynxt Topical Report Project stage: Other ML21015A1292021-02-0202 February 2021 Transmittal Regarding Verification of Accepted Proprietary and Non-Proprietary Versions of Framatome Topical Report, BAW-10241P-A. Revision 2, Bhtp DNB Correlation Applied with Lynxt Topical Report Project stage: Other 2020-08-04
[Table View] |
Text
December 1, 2020 Mr. Gary Peters, Director Licensing and Regulatory Affairs Framatome Inc.
3315 Old Forest Road Lynchburg, VA 24501
SUBJECT:
AUDIT REPORT AUGUST 18 - 20, 2020 REGULATORY AUDIT PLAN FOR ERRATA TO FRAMATOME INC. TOPICAL REPORT BAW-10241PA, REVISION 1, BHTP DNB CORRELATION APPLIED WITH LYNXT TOPICAL REPORT (EPID L-2020-TOP-0038)
Dear Mr. Peters:
By letter dated June 30, 2020 (Agencywide Documents Access Management System Package Accession No. ML20188A238), Framatome Inc. (Framatome) submitted a request for review and approval of Errata to Topical Report (TR) BAW-10241PA, Revision 1, BHTP DNB Correlation Applied with LYNXT Topical report. The proposed Errata to the TR details minor changes to BAW-10241PA, Revision 1.
The NRC staff conducted a virtual regulatory audit to increase their level of knowledge and understanding of the changes to TR BAW-10241PA, Revision 1, on August 18 through 20, 2020. The results of the audit will provide additional support for the NRC staff safety evaluation of the TR. The audit report is enclosed.
Please contact Ngola Otto at 301-415-6695 or via e-mail at Ngola.Otto@nrc.gov with any questions you may have regarding this letter.
Sincerely,
/RA/
Dennis C. Morey, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 99902041 Project No. 728
Enclosure:
Audit Report (Non-Proprietary)
ML20335A004 (Package);
ML20335A005 (Letter);
ML20335A006 (Audit Report)
- Via e-mail OFFICE NRR/DORL/LLPB/PM*
NRR/DORL/LLPB/LA*
NRR/DSS/SFNB/BC*
NRR/DORL/LLPB/BC*
NAME NOtto DHarrison RLukes DMorey DATE 11/27/2020 11/30/2020 12/1/2020 12/1/2020