ES-401, REV 11 T1G1 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 007EA2.05 Reactor Trip - Stabilization - Recovery 3.4 3.9 Reactor trip first-out indication

/ 1 008AK2.02 Pressurizer Vapor Space Accident / 3 2.7 2.7 Sensors and detectors 009EG2.4.50 Small Break LOCA / 3 4.2 4.0 Ability to verify system alarm setpoints and operate controls identified in the alarm response manual.

015AK2.08 RCP Malfunctions / 4 2.6 2.6 CCWS 025AK1.01 Loss of RHR System / 4 3.9 4.3 Loss of RHRS during all modes of operation 026AA1.02 Loss of Component Cooling Water / 8 3.2 3.3 Loads on the CCWS in the control room 027AK2.03 Pressurizer Pressure Control System 2.6 2.8 Controllers and positioners Malfunction / 3 029EA2.01 ATWS / 1 4.4 4.7 Reactor nuclear instrumentation 038EG2.1.25 Steam Gen. Tube Rupture / 3 3.9 4.2 Ability to interpret reference materials such as graphs, monographs and tables which contain performance data.

040AK3.03 Steam Line Rupture - Excessive Heat 3.2 3.5 Steam line non-return valves Transfer / 4 054AK3.02 Loss of Main Feedwater / 4 3.4 3.7 Matching of feedwater and steam flows Page 1 of 2 11/15/2019 8:02 AM

ES-401, REV 11 T1G1 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 055EK1.01 Station Blackout / 6 3.3 3.7 Effect of battery discharge rates on capacity 056AA1.29 Loss of Off-site Power / 6 2.7 2.7 CCW heat exchanger temperature control valves 057AK3.01 Loss of Vital AC Inst. Bus / 6 4.1 4.4 Actions contained in EOP for loss of vital ac electrical instrument bus 058AA1.01 Loss of DC Power / 6 3.4 3.5 Cross-tie of the affected dc bus with the alternate supply 062AA2.01 Loss of Nuclear Svc Water / 4 2.9 3.5 Location of a leak in the SWS 065AG2.4.1 Loss of Instrument Air / 8 4.6 4.8 Knowledge of EOP entry conditions and immediate action steps.

077AK1.03 Generator Voltage and Electric Grid 3.3 3.4 Under-excitation Disturbances / 6 Page 2 of 2 11/15/2019 8:02 AM

ES-401, REV 11 T1G2 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 005AA2.02 Inoperable/Stuck Control Rod / 1 2.5 3

Difference between jog and run rod speeds effect on CRDM of stuck rod 028AK3.02 Pressurizer Level Malfunction / 2 2.9 3.2 Relationships between PZR pressure increase and Reactor makeup/letdown imbalance 036AK3.01 Fuel Handling Accident / 8 3.1 3.7 Different inputs that will cause a reactor building evacuation 037AG2.2.38 Steam Generator Tube Leak / 3 3.6 4.5 Knowledge of conditions and limitations in the facility license.

061AA1.01 ARM System Alarms / 7 3.6 3.6 Automatic actuation 067AA2.10 Plant Fire On-site / 8 2.9 3.6 Time limit of long-term-breathing air system for control room 068AK2.03 Control Room Evac. / 8 2.9 3.1 Controllers and positioners 076AA1.04 High Reactor Coolant Activity / 9 3.2 3.4 Failed fuel-monitoring equipment CE09EK1.1 Functional Recovery / None 3.4 3.7 Components, capacity, and function of emergency systems.

Page 1 of 1 11/15/2019 8:03 AM

ES-401, REV 11 T2G1 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 003K4.07 Reactor Coolant Pump 3.2 3.4 Minimizing RCS leakage (mechanical seals) 004A2.09 Chemical and Volume Control 3.0 3.9 High primary and/or secondary activity 004A2.35 Chemical and Volume Control 3.3 3.8 Reactor trip 005K2.01 Residual Heat Removal 3.0 3.2 RHR pumps 005K6.03 Residual Heat Removal 2.5 2.6 RHR heat exchanger 006K2.04 Emergency Core Cooling 3.6 3.8 ESFAS-operated valves 007K5.02 Pressurizer Relief/Quench Tank 3.1 3.4 Method of forming a steam bubble in the PZR 008A1.02 Component Cooling Water 2.9 3.1 CCW temperature 008K4.02 Component Cooling Water 2.9 2.7 Operation of the surge tank, including the associated valves and controls 010K3.01 Pressurizer Pressure Control 3.8 3.9 RCS 010K6.01 Pressurizer Pressure Control 2.7 3.1 Pressure detection systems Page 1 of 3 11/15/2019 8:03 AM

ES-401, REV 11 T2G1 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 012G2.2.25 Reactor Protection 3.2 4.2 Knowledge of the bases in Technical Specifications for limiting conditions for operations and safety limits.

013K2.01 Engineered Safety Features Actuation 3.6 3.8 ESFAS/safeguards equipment control 022A1.04 Containment Cooling 3.2 3.3 Cooling water flow 026A4.05 Containment Spray 3.5 3.5 Containment spray reset switches 039K1.02 Main and Reheat Steam 3.3 3.3 Atmospheric relief dump valves 059A3.07 Main Feedwater 3.4 3.5 ICS 061K6.02 Auxiliary/Emergency Feedwater 2.6 2.7 Pumps 062A2.08 AC Electrical Distribution 2.7 3.0 Consequences of exceeding voltage limitations 063A3.01 DC Electrical Distribution 2.7 3.1 Meters, annunciators, dials, recorders and indicating lights 063G2.4.41 DC Electrical Distribution 2.9 4.6 Knowledge of the emergency action level thresholds and classifications.

064K3.03 Emergency Diesel Generator 3.6 3.9 ED/G (manual loads)

Page 2 of 3 11/15/2019 8:03 AM

ES-401, REV 11 T2G1 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 073A1.01 Process Radiation Monitoring 3.2 3.5 Radiation levels 073K5.02 Process Radiation Monitoring 2.5 3.1 Radiation intensity changes with source distance 076A3.02 Service Water 3.7 3.7 Emergency heat loads 076K4.03 Service Water 2.9 3.4 Automatic opening features associated with SWS isolation valves to CCW heat exchanges 078K1.05 Instrument Air 3.4 3.5 MSIV air 103G2.2.36 Containment 3.1 4.2 Ability to analyze the effect of maintenance activities, such as degraded power sources, on the status of limiting conditions of operations Page 3 of 3 11/15/2019 8:03 AM

ES-401, REV 11 T2G2 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 015K5.10 Nuclear Instrumentation 2.8 3.0 Ex-core detector operation 017A3.01 In-core Temperature Monitor 3.6 3.8 Indications of normal, natural and interrupted circulation of RCS 027G2.4.46 Containment Iodine Removal 4.2 4.2 Ability to verify that the alarms are consistent with the plant conditions.

028A2.01 Hydrogen Recombiner and Purge 3.4 3.6 Hydrogen recombiner power setting, determined by Control using plant data book 034K1.02 Fuel Handling Equipment 2.5 3.2 RHRS 041K6.03 Steam Dump/Turbine Bypass Control 2.7 2.9 Controller and positioners, including ICS, S/G, CRDS 055K3.01 Condenser Air Removal 2.5 2.7 Main condenser 071K4.04 Waste Gas Disposal 2.9 3.4 Isolation of waste gas release tanks 072A1.01 Area Radiation Monitoring 3.4 3.6 Radiation levels 075K2.03 Circulating Water 2.6 2.7 Emergency/essential SWS pumps Page 1 of 1 11/15/2019 8:04 AM

ES-401, REV 11 T3 PWR EXAMINATION OUTLINE FORM ES-401-3 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO G2.1.4 Conduct of operations 3.3 3.8 Knowledge of individual licensed operator responsibilities related to shift staffing, such as medical requirements, "no-solo" operation, maintenance of active license statur, 10CFR55 etc.

G2.1.5 Conduct of operations 2.9 3.9 Ability to locate and use procedures related to shift staffing, such as minimum crew complement, overtime limitations, etc.

G2.2.37 Equipment Control 3.6 4.6 Ability to determine operability and/or availability of safety related equipment G2.2.40 Equipment Control 3.4 4.7 Ability to apply technical specifications for a system.

G2.2.6 Equipment Control 3.0 3.6 Knowledge of the process for making changes to procedures G2.3.12 Radiation Control 3.2 3.7 Knowledge of radiological safety principles pertaining to licensed operator duties G2.3.15 Radiation Control 2.9 3.1 Knowledge of radiation monitoring systems G2.4.19 Emergency Procedures/Plans 3.4 4.1 Knowledge of EOP layout, symbols and icons.

G2.4.3 Emergency Procedures/Plans 3.7 3.9 Ability to identify post-accident instrumentation.

G2.4.50 Emergency Procedures/Plans 4.2 4.0 Ability to verify system alarm setpoints and operate controls identified in the alarm response manual.

Page 1 of 1 11/15/2019 8:05 AM

ES-401, REV 11 SRO T1G1 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 008AA2.16 Pressurizer Vapor Space Accident / 3 3.8 4.1 RCS in-core thermocouple indicators; use of plant com-puter for interpretation 015AA2.02 RCP Malfunctions / 4 2.8 3

Abnormalities in RCP air vent flow paths and/or oil cooling system 040AG2.4.18 Steam Line Rupture - Excessive Heat 3.3 4.0 Knowledge of the specific bases for EOPs.

Transfer / 4 054AA2.06 Loss of Main Feedwater / 4 4

4.3 AFW adjustments needed to maintain proper T-ave. and S/G level 057AG2.1.25 Loss of Vital AC Inst. Bus / 6 3.9 4.2 Ability to interpret reference materials, such as graphs, Curves, tables, etc.

077AG2.4.3 Generator Voltage and Electric Grid 3.7 3.9 Ability to identify post-accident instrumentation.

Disturbances / 6 Page 1 of 1 11/15/2019 8:15 AM

ES-401, REV 11 SRO T1G2 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 024AG2.2.39 Emergency Boration / 1 3.9 4.5 Knowledge of less than one hour technical specification action statements for systems.

037AG2.2.37 Steam Generator Tube Leak / 3 3.6 4.6 Ability to determine operability and/or availability of safety related equipment 069AA2.01 Loss of CTMT Integrity / 5 3.7 4.3 Loss of containment integrity CA11AA2.1 RCS Overcooling - PTS / 4 2.9 3.3 Facility conditions and selection of appropriate procedures during abnormal and emergency operations.

Page 1 of 1 11/15/2019 8:15 AM

ES-401, REV 11 SRO T2G1 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 003A2.03 Reactor Coolant Pump 2.7 3.1 Problems associated with RCP motors, including faulty motors and current, winding and bearing temperature problems 008G2.4.46 Component Cooling Water 4.2 4.2 Ability to verify that the alarms are consistent with the plant conditions.

010G2.2.22 Pressurizer Pressure Control 4.0 4.7 Knowledge of limiting conditions for operations and Safety limits.

013A2.03 Engineered Safety Features Actuation 4.4 4.7 Rapid depressurization 022A2.02 Containment Cooling 2.3 2.6 Fan motor vibration Page 1 of 1 11/15/2019 8:17 AM

ES-401, REV 11 SRO T2G2 PWR EXAMINATION OUTLINE FORM ES-401-2 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO 016A2.02 Non-nuclear Instrumentation 2.9 3.2 Loss of power supply 027G2.4.45 Containment Iodine Removal 4.1 4.3 Ability to prioritize and interpret the significance of each annunciator or alarm.

072A2.03 Area Radiation Monitoring 2.7 2.9 Blown power-supply fuses Page 1 of 1 11/15/2019 8:18 AM

ES-401, REV 11 SRO T3 PWR EXAMINATION OUTLINE FORM ES-401-3 KA NAME / SAFETY FUNCTION:

IR K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G TOPIC:

RO SRO G2.1.30 Conduct of operations 4.4 4.0 Ability to locate and operate components, including local controls.

G2.2.14 Equipment Control 3.9 4.3 Knowledge of the process for controlling equipment configuration or status G2.2.35 Equipment Control 3.6 4.5 Ability to determine Technical Specification Mode of Operation G2.3.14 Radiation Control 3.4 3.8 Knowledge of radiation or contamination hazards that may arise during normal, abnormal, or emergency conditions or activities G2.3.4 Radiation Control 3.2 3.7 Knowledge of radiation exposure limits under normal and emergency conditions G2.4.41 Emergency Procedures/Plans 2.9 4.6 Knowledge of the emergency action level thresholds And classifications.

G2.4.11 Emergency Procedures/Plans 4.0 4.2 Knowledge of abnormal condition procedures.