ML20289A650
| ML20289A650 | |
| Person / Time | |
|---|---|
| Issue date: | 10/08/2020 |
| From: | Tim Reed Division of Operating Reactor Licensing |
| To: | |
| Kichline M | |
| Shared Package | |
| ML20289A715 | List: |
| References | |
| Download: ML20289A650 (5) | |
Text
History of 10 CFR 50.155 Mitigation of Beyond-Design-Basis Events Requirements Tim Reed USNRC September 2020 1
Events Leading to New Mitigation Strategy Requirements
- Earthquake in Japan occurs - March 11, 2011
July 2011
- Commission issues its SRM on SECY-11-0124 and SECY-11-0137 2
Post-Fukushima Regulatory Actions (During 2012)
NRC Orders Issued on March 12, 2012:
- EA-12-049 (Mitigation Strategies)
- EA-12-050 (Mark I/II Hardened Containment Vents - becomes EA-13-109)
- EA-12-051 (Spent Fuel Pool Instrumentation)
NRC Issues 10 CFR 50.54(f) Requests for Information on March 12, 2012 Two Advance Notice of Proposed Rulemakings (ANPR) issued
- Station Blackout ANPR issued March 2012
- Onsite Emergency Response Capabilities issued in April 2012 NRC and industry develop and issue EA-12-049 implementing guidance in August 2012 (JLD-ISG-2012 endorses NEI12-06 rev 0) 3
Mitigation of Beyond-Design-Basis Events (MBDBE) Rulemaking
- Proposed MBDBE Rule issued for public comment in November 2015
- Draft Final MBDBE rule provided to the Commission in December 2016 (SECY-16-0142)
- Commission acts on final rule (SRM-SECY-16-0142) in January 2019
- Final MBDBE rule issued August, 9, 2019 with effective date of September 9, 2019 4
Impact of Changes to MBDBE rule
- Removed draft requirements not supportable under backfit or moved back into 50.54(f)
- Seismic and flooding reevaluated hazards addressed on plant-specific basis under 10 CFR 50.54(f)
- Any additional requirements must meet backfit
- Impacted Guidance: Draft Regulatory Guide 1.228 was discontinued
- Impacted Regulatory Guide 1.226
- Guidance for addressing reevaluated hazards in appendices G and H not required for compliance with 10 CFR 50.155 5