I 4160 V SKGR BUS SECT. F A------------
B----+-------
II 2
ii27DCHF l 5
'ls2HF1S s rn CONTACTS POSITIONS A
INT B INT: C l -t~f---2 I
X X
X X
c------------
2 r~ R I 62HF I 5 2
X X
52HFIS 75/511 f,Oo/511 SO/SA MHF/5 I
I J-{-<r l l LI J
~
n h
LI u
u 11.,
n
}
70 8US SECTION F BUS DIFFE'.ReNT/1\\L SEE DWG. 441343 L-it--+---<>-'-<>--
SONHF/5 r------,
I,
- lil I "A_-_4;~~~--<>-r<>-----..._
I
'I--+-+--<>---<: >------~I-<>
~T I I 7
~
I L---- __ _J
.A 8
C w THREE LINE DIAGRAM D. C CONT. BUS UNDEPMX.T/IGE I
MANUAL CLOSE I
I AM
.;,!:ff§_
Q§_
- oc-c--------~
.,j,.
'""" f- "" -1'
( I OH _J;'
SHH l 5 CNSI DETA I L A FOR S I PP 2-2 ONL Y AUTO CLOSE I
INDICATION I
SAFETY INJ ECTION S IGNAL I
I
~
REF. DI\\G 441340 e=
MANUAL TR IP M l TDD T l 27DCI MI HF 15
~--------------------1 I
CNS I 1
SHF I 5 ~
BF ----:'.?,
i C>p i:
I 1 0 F ------0 3 -li-,3C 3
X X
7-1 ~ 7C 7
X X
X lf-tr-llC II AMMETER SWITCH X
X AM SW USED AT LOCATION SI-/FIS, SHHIS SHF l 5 CNS I
'- -------=-=-=-=------~
--'~ FOR SI PP 2-2 POTENT IAL I NT ER LOC~
I AUTO TRIP I
14KV BUS UV, OYERWRRE~
I I
SEE DET AI L " A" BELO\\/ LEFT
.5.IS TIME..PEt..AY REI..A Y OVERCURRENT I
AUXILIARY RELAY ltNDICATIONl I
I t--(]U=T-]0~2---4...--,,._. _ _.!S~*H~~i=-ISPT~Q!.~S~I------------------------------+----<<.~---,.----t---------------l-----------------
L..!.Jt-c '=:c------------------------------------+----~-',ti..:..._-+----+-----,
- b.
UT*OI
'::I.B..:..Q.1 L..{0}-<;>--PC-o-----<~*-------- --------------~
I~
Q!fil c
(0--
B __ 52HF/5 I
ICS/ STAAT SZHFIS IC. CS/CLOSE S2HFl.5 CI CS//IEU T.
.START G
t ',
R A S2HFIS Tc.sJSTCIP 2
~---
J,,
2C 52HF/5 cslTRIP
, SHFl3 34T27XHF T
/i. Rco p 'h 51HFl5 Sl/f/5 I
3A BO 3J.. co A?CNSI D1 CNSl
£2 4sHFIS Tl 12HFIS i,n1 TDC CJJSI 8 'fCNSI
\\Tco roe I INST 6
2y 6y 2y 6y z y I
.JG 2
SHFIS
, SHFIS it
~
S/IF/ff 2*/
g,,CNSI E,,,--52H' 15
~~ CS/ NEU T. START
~
J
)SN!=/5
~
'1v RES.
ir 40().Q.
S
/DOW SEf A, !AU.,,_
UC -01 0
~rl.L_
.Jt--
---...~-+----------------------+---1 B 125 V DC CONTROL SCHEMATIC 62HFl5 TD
~ Tl R I T2 R2 T3 R3 -4 R4 SAFETY INJECTION PUM,0 N9 21, CIRCUIT N9 F/5HOO
., tt:~UiLJiLJ iB4 -**-***- MI -*-*** M2 -*****-M3 -*-*--* M4 _.
TYPICAL SC/IEMATIC p1AGRAM FOR SAFETY INJECTION FUMP N~* i?.I & 22 EXCEPT AS ~OWN IN TABLE BELOW MOTOR MOTOR cxr BKR. C/RCVIT BUS DC BUS UNDERVOLTAGE A LA RM CIRCUIT NQ 's Nfl LOC. N9 N9 NQ SECTION CKT N<l RELAY LOC/'iTTON CONTACT O>fiRCURf?Bfl GROUND CONT. BUS TRIP DVERCURRE.N, DC UV 2/
MHF/5 SWFJS FISHOO F
1/3D 27J<.HFT SH!=l3
~C>-11---0J AIO!JOODF AIO!J02DF AV4407DF 22 MHH/5 52HHl5 HISHOO H
314D 27)(.HHT SHHl3
% 0-H-oJ, AIO!JOODH AI0903DH.Al/4207DH I
I I
I I
7 S/'11 _ __
Jlflf - -
B B
.1'fcNSI D
SHFIS I
7 I
I 9
I 10 TABLE OF DEVICES DEVICE NP FUNCTION RATING : MFR TYPE CAT.(DfVG,}I',
REMARKS POSIT ION S m
Cl:JHTACTS TRIP TRIP CLOS< REMARKS 2HF!6 ZJ.lf{II:>
SAFETY INJECTION SIGNAL TIMING REL ! 120V AC 14(;ASTAT --
kEFEREI-Jt:e.. 14-
',SAf'lifY 11.Jn;crl<N SJ!;NAt-TIM11.JGr !is-,'-*-"+
1,:'a 2"'0--v-;A'=c+-AAA-:=-::cc,,sr,='i'.-:::i--1---+----+,,=,
_, _-=
__ "'_""-"-*c=-e=-,=
,,--l
~Nrr I --t t---JC X
TI-IIS DM; 2-il-ZC X
THIS DKG 3 -
H-JC X
X SPARE 4--lt-4C X
SPARE 5----ll-SC X
X SPARE SC--t 7-il-7t X
X SPARE JC-;
CONTROL SWI TCH ~
QHH/5 cs cs USED AT LOCATION SHF/5 S!if!!§ SPRING RETURN 1tl NEUTRAL CONTACTS
- A
--ii-B
--if-C
--ii-D
- E
--1 1-F POS ITIONS REMARKS STOP NEUT ST'ART X
THIS DIM;.
X THIS D"'5-X X
THIS uv.G X
SPARE X
X THIS DtvG SPARE S2HFJ5 52HHl5 CONTROL SWITCH -c:s-
~
USED AT LOCATION CNSI SPRING RETURN TO NEUTRAL ZTOCHFIS,HH~ DC COJITRO(. OOS UNDERVOLT4E REL IZSY DC G.E. Cl,.
HGA 27/IJIFT, HHT 4 XV UNDER'-,0<.. TAGE TRIP AW<. REL.
17DCIHfl5. HHl5 DC CONTROL BUS UNDERI/OLTAGE RELAY 125'1 DC AGASTA T EGPO 62HF15,HHl5 BKR CLOS ING SPR ING TIME DELAY REL AY 125 1' DC AGASTAT ET ~
',sONHFIS,HH/!, GROUND DVERCURRENT SENSOR SIHFIS,H/115 OVERCURRENT RELAY SIXJIFIS, HHIS OVERCURRENT.AIJJ!./LIARY REI..AY 24V DC G.£ Co.
H~A S2HFl5, HH/5 CIRCUIT BRE AKER
~.~
CI RCUI T BREAKER AU X Sf/ITCH
~
.52~~15 CI RCUI T BREAKER CEL L INTLK (6), (7)
(3), (IZ)
(3), ( 12)
(3), ( 12)
TRI PS ON UNDERVO L TAGE
PART OF SMilR.
CONTROL TRANSFER RELAYS
!MONITOR L IGHT!
0 270( 1 HF 15 I CONTACT I SHFIS 13TH/IO 19
>-- L/ --O S2HFIS
- ~
- 21)
>-L2--<>
SHFIS BTHIID r ILJI R I TW'""~I t 'U4 R4 3
"'"'U"'
_J a..
a..
j_g
..,en en
- B4. -..... M 1._.... MZ....... M3 ***-***M4._
£QUIPM£NT LOCATION NUMBERS TE.RMINAL l30X AREA H N r2 110 BTH / tO CNS!
MHF/5 SHFIS CONTROL BOARD SAFETY INJECTION SAFE.TY INJECTION PUMP Nfl 21 SWITCHGEAR 4 KV BUS F CUBICLE /5 DATE I I 2009 REFERENCES t DESCRIPTION OF ELE.C. SCHeMAT/C DIAG.'s,SrMBOLS ~ CXT DESl6NATIONS _________ 050003
- 2. EQUIPMEJ.IT LOCATION NUMBERS _ _____ _ _ _ __ _ ___ _ ____ _ _ _ _____ __ __ _ ___ _ 10 3013
- 3. SING.LE LINE METeR & RELAY DIAG 4160 V SYSTEM SH.2 ( BUSF, _________ *"'4/2 29
- 4. SINGLE LIN£ METER & RELAY DIAG. / 2S V OC SYSTEM ___________________.44/240 S. SCHEMATIC DIAG. 4160V 8US DIFFERENTIAL SH. 2 _______________________ _ 441.343
'- SCHEMATIC DIAG. 4/bOV BUS F
AU70MATIC TRANSFER __________________.441352
- 7. SCHEMATIC D11'1.G. 4160V BUS H
AUTOMATIC TRIWSFE'.R __________________ 441354 8 SCHEMATIC DIAG. POTENTIAL & SYNCHRONIZING 4160V SYSTE.M _____________ 441340
- 9. LOGIC DIAGRAM SAFE.TY INJECTION PUMPS __________________________ /0 27':J4 ID. PIPING SCHEMATIC SA FETY INJECTION SYSTEM _______________________ ! D8005,
{I. SCHEMATIC DIAG. MAIN ANNUNCIATOR SH f ____ _ __ _ ______ _ ____ __ __ _ _ _ _.500171 12 SINGLE L/NE ME.TE.R & RELAY DIAG 4lr;;O V SYSTEM SH3 (SUS G 1/,H) _______ _441230
/3. SCHEMATIC DIAGRAM MONITOR LIGHT /3QX C __________________________ _4414f4-'
14.usr OF tLecrRtc.AL :Pl=VJCl:;5 /'OR,.~~c:rtOJ*Ui C0J.dR()L CIR.CI.IIT5 ------------ 05001/
I 5.
P. D.S.
CONTROL CIRC UITS SCHEMATIC DI AGRAM~5009838-69 16. SCHEM ATIC DIAG AUX & FUE L HAND L I NG BLOCS VEN T I L AT ION SYS <PO V I 1 _____ 454671 17,
SCHEMAT IC DIAG AUX & FUEL HANDL I NG BLDGS VENTI L AT ION SYS <POV 21 _____ 454 678 KEY DWG. SECT ION 4 I
NUCLEAR SAFETY RELATED U~l l T 2 ELECT R ICAL SCHE MAT I C DIAGRAM SA FETY I NJEC TION PUMP DI ABLC CANYON PO'NER PLANT PACIFIC GAS AND ELECTRIC COMP ANY SAN FRANCISCO, CAL I FORN I A I
I OWG SCALE:
BlLL OF MATU SUPSDS:
SUPSD BY:
~
,,,l B
C P.G. &E.
SYST EM PHASE SEQUENCE A-C-8 rOLD U7 I-OL D~