5 to Updated Final Safety Analysis Report, Chapter 4, Drawing 6006510, Rev. 0, Sheet 1
ML20268A796
Person / Time
Site: Diablo Canyon  
Issue date: 06/30/2020
From:
Framatome Cogema Fuels, Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20268B299 List: ... further results
References
DCL-20-075
Download: ML20268A796 (1)


Text

8 7

F z

E (d

=

ra

=

(d ra

=

=

(d (d

='

=

ff D

z 4X 4X C

8 B

---...___ 24X SEE NOTE 3 SECTION Y-Y SCALE: 6:1 A

8 7

6 5

4 24X SEE NOTE 2 i---------( 7.169 ) -----------~

(5.954)

~

p X

X

~

y

~

= n

( 6.809 )

(161.0)

SECTION Z-Z 0

RCCA 24X SEE NOTE 4 SECTION X-X SCALE: 2:1 6

5 1i I I ti l r I

I ti I I 4

3 1i I 11.D I I fl I I~

I I

( 150.574 )

1i I IID I I 1i I I I 110.

Til!S OOCUMENT WAS NOf PREPARED UNDE!lMY DIRECTCONIRCT.

AND PEFSON/\\L SUPE!lVISION, BUT I HAVE PERro!lMED A FIN/\\L OVER.All.REVIEW OF lHEDESIGN AND SUPPORTING DOCUMENTATION AND APPROVED A SUMv!ARY CALCTJLATION/50.59 EVALUATION THAT CONFIRMED lHE P.CCA DESIGN DRAWINGS ARE IN COMPLIANCE WIIB TI-IE APPLlCABI..E DESI ON REQUIREMENTS FOR TilEIR INTENDED USE.

~~-r-7!.11_...* a A f 7 5/!f"/01 3

COORDINATION CK D11C1P1.H arDBr ~TE

. 0 2

REVISIONS REV DESCRIPTION 0

THIS DRAWING WAS CREATED PER DCR 2084.

1 DATE APP FOR SIGNATURES AND DATE SEE TITLE BLOCK BELOW.

NOTES:

1.

CONTROL ROD ASSEMBLY, INSPECTION AND CLEANLINESS SHALL BE IN ACCORDANCE WITH SPECIFICATION 08-1229096.

2.

INSERT ITEM 8 INTO ITEM 2 AND ITEMS 5 THRU 7.

TORQUE ITEMS 3 AND 4 TO 15+/-5 IN. LBS PRIOR WELDING.

3.

USE APPROXIMATELY 1 /8 DIAMETER FUSION SPOT WELD TO SECURE ITEM 8 TO ITEM 2.

THE MINIMUM WELD PENETRATION SHALL BE.029 INCH.

THE EXTERNAL SURFACE OF THE WELD SHALL NOT EXCEED THE SPIDER SURFACE BY MORE THAN 5 MILS.

4.

USE TWO (2) APPROXIMATELY 1 /8 DIAMETER FUSION SPOT WELDS TO SECURE ITEMS 3 AND 4 TO ITEM 2.

THE WELDS SHALL BE PLACED APPROXIMATELY +/-90. FROM ITEM 8.

THE MINIMUM WELD PENETRATION SHALL BE

.045 INCH.

THE EXTERNAL SURFACE OF THE WELDS SHALL NOT EXCEED THE SURFACE OF ITEM 2, 3 OR 4 BY MORE THAN 5 MILS.

5.

GAP SHALL BE MEASURED BEFORE AND AFTER ITEM 8 WELD.

6.

THE GAP MEASUREMENT SHALL BE CONDUCTED IN ALL ROD LOCATIONS ON ALL RCCA'S MANUFACTURED.

THE WEIGHT OF THE ASSEMBLED RCCA IS 1 49 LBS.

DC6006510- I SC~N I IC I 1-"AGEJ, 8

24 7

4 6

4 5

16 4

4 3

20 2

1 1

ITEM QTY 1187154-003 C

LOCK PIN 1274240-004 D

CONTROL ROD C (LONG) 1274240-002 D

CONTROL ROD B (MEDIUM) 1274240-001 D

CONTROL ROD A (SHORT) 1184874-002 C

NUT TYPE-B 1224241-001 C

NUT TYPE-A 1198719-005 E

SPIDER ASSEMBLY 1274241-001 F

RCCA DWG NO.

SUFFIX OS F/P DESCRIPTtON PART NO.

BILL OF MATERIAL TOLERANCES UNLESS OTHERWISE SPECIFIED ALL TOLERANCE DEFINITIONS PER ANSI Y14.5M-1982 SURFACE FINISH PER ANSI/ASME B46.1-1985 ALL DIMENSIONS ARE FOR PART TEMPERATURE OF 68"F UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN INCHES UP TO 6"1NCL Ov£R 6" TO 12* INCL OVER 12"'

TO 24'" INCL OVER 24" OVER 72" TO TO 72* INCL 1sa* INCL.

MAT'L SPEC OVER 155*

3 PLACE DIM. MACHINED

+/-.003"

+/-.005"

+/-,005"

+/-.010*

+/-.OJ1

  • 2 PLACE D1M. "-'CHINED

+/-.02"

+/-.03"

i:.03" 2 PLACE DIM. UNMACHINED

+/-.06"

+/-.06"

+/-,13" FLATNESS

.001" IN. OF SURFACE UP TO.020* MAX.

@~

PERPENDICULARITY

.002* lN. OF SURFACE UP TO.020" MAX.

~~ CONCENTRICfTY

.015" DIA.

~§ ANGULHU1Y

+/-0--JO'

+/-.06"

+/-.13'"

+/-.06"

t:,,-3*

+/-.19..

t.19" 8REAK CORNERS

.02" MAX. RAfl<US OR CHAMFER CH>NFER +/-5°

ZIJ) fil MACHINED SURFACES TO HAVE J.18 Ro 125M FINISH UNLESS OTHERWISE NOTED RCCA DO NOT SCALE.

US£ DIMENSIONS ONLY 2

1HIS DRAWINO JS THE PMPE:RlY Of FRAMATOME COGEMA FUELS 1H) IS LCWED lPON OONM10N THAT Tr 1$ NOr 10 BC REPft0DUCED OR COPIED fl WI-ICU OF! 1H PM!', OR USED FOR AJRNISHIG NF!JRIW'ION TQ ~

OR FOR Ntf 11\\lB PU!POS DEJRIIEMW. TO TH[

MEREST OF ~E COIEM FUELS NCO Will. BE IE'VRKED IJP(H REQUEST,

...,, 1:1 SHEET 1 OF 1 F 02 1274241 0

9-1--00 1

F E

D C

B A