ML20268A745

From kanterella
Jump to navigation Jump to search
5 to Updated Final Safety Analysis Report, Chapter 3, Drawing 108007, Rev 51, Sheet 5A, Reactor Coolant System
ML20268A745
Person / Time
Site: Diablo Canyon  
Issue date: 06/30/2020
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20268B299 List: ... further results
References
DCL-20-075
Download: ML20268A745 (1)


Text

A B

C D

en 0

N I

N I

C N

01 "IJ

  • C **

o OlQJ

~E I

I r-- <( 'ST Olf1Vl 0,z CO r-- N O O.*

-OL II 00 Q) er:: 0

(/)

w-=i f--

II l/lZO

<(C)<(

cr::ou 50A 51A TE-495R SPARE TE-495S SPARE TE-495T SPARE TE-495U SPARE TE-495N SPARE TE-4950 SPARE TE-495P SPARE TE-495Q SPARE TE-495E INT 83G-A 36 NOTE I

T0416A HI A/LOA 82G-A 36 YT 450B DISCHARGE NOTES:

I. TEMPORARY READOUT FOR SELECTED PUMP MONITORING CONNECT TO VIBRATION TRANSMITTER AS REQUIRED. (51A-D)

2. DELETED
3. FOR INSTRUMENT ORIENTATION, SEE DWG N0.054174,FIG.926,SHT.29. (55A-D)
4. INSTRUMENT SCHEMATIC COORDINATES OF VIBRATION TRANSMITTERS FOR PUMPS 2, 3

& 4 ARE NOT PROVIDED ON THIS SHEET; SEE SHEETS SH, 8 I & BJ OF DWG I 08036 (58A-D)

5. ADDITIONAL SPARE STATOR WINDING RTD'S ARE INSTALLED, BUT ARE NOT CONNECTED TO A TERMINAL BLOCK. SEE REWIND REPORT t-1 663207-227 CRCP 2-1 ), 663207-210 CRCP 2-2),

£(§63207-257 CRCP 2-3>) AND 663207-229 CRCP 2-4).

3NPGIC 3 size FOR ADD IT I ONAL RTD LOCATIONS. (5BA-A) 52A OUTBOARD MOTOR

~-INBOARD BIG-A TE-496A T0413A REACTOR COOLANT PUMP 2-1 53A TE-495A T0414A TE-407A T0412A TE-496E T0415A 84G-A 36 SUCTION REACTOR 54A TE-495J SPARE TE-495K SPARE TE-495L SPARE TE-495M SPARE NOTE 3 COOLANT PUMPS I 2-I 2-20 I 9 ZNS4 FXC2 N/ A NOT REQUIRED PER CF3. I D5 DATE OWN RE IV PROFESSIONAL ENGINEER PE DISC.

55A 56A 57A 58A 59A A I

£


~_,___N~OTE5 I

=

INSTRUMENT PUMP 2-1 UPPER OIL RESERVOIR FOR UPPER LC-494A RADIAL AND THRUST BEARING LI-494A LC-494E LOWER OIL RESERVOIR Ll-494E STATOR WINDING SLOT TE-407A COMPUTER POINT NO.

52 T0412A SLOT TX-408A 64 SLOT TX-409A 76 STATOR WINDING SLOT TX-410A 106 SLOT TX-41 IA 10 SLOT TX-412A 22 THRUST BEARING UPPER SHOE.

TE-495A COMPUTER POINT NO.

T0414A THRUST BEARING LOWER SHOE.

TE-495E COMPUTER POINT NO.

T0416A UPPER RADIAL BEARING TE-496A COMPUTER POINT NO.

T0413A LOWER RADIAL BEARING TE-496E COMPUTER POINT NO.

T0415A TE-495J THRUST BEARING UPPER SHOE SPARE TE-495N THRUST BEARING LOWER SHOE SPARE TE-495R UPPER RADIAL BEARING SPARE PC-497A OIL LIFT PUMP PRESSURE PI-497A MOTOR SHAFT RADIAL X-PROBE YT-450A VIBRATION Y-PROBE YT-450B PUMP SHAFT RADIAL X-PROBE YT-451A VIBRATION Y-PROBE YT-451B KEYPHASOR YT-454 VELOCITY-X (CHANNEL A)

YT-455A VELOCITY-Y (CHANNEL B )

YT-455B INSTRUMENTATION Revised Per DDT-4*1874 PE EXP.

PUMP 2-2 LC-494B LI-494B LC-494F Ll-494F TE-407B T0432A (SLOT 7)

TX-408B

<SLOT I 9)

TX-409B

( SLOT 3 I )

TX-410B

( SLOT 6 I )

TX-4 I I B

<SLOT 73)

TX-412B (SLOT 85)

TE-495K T0434A TE-495F T0436A TE-496B T0433A TE-496F T0435A TE-495B FAILED SPARE TE-4950 SPARE TE-495S SPARE PC-497B PI-497B YT-460A YT-460B YT-461A YT-461B YT-464 YT-465A YT-465B PUMP 2-3 LC-494C Ll-494C LC-494G Ll-494G TE-407C T0452A TX-408C TX-409C TX-410C TX-411C TX-412C TE-495C T0454A TE-495G T0456A TE-496C T0453A TE-496G T0455A TE-495L SPARE TE-495P SPARE TE-495T SPARE PC-497C PI-497C YT-470A YT-470B YT-471A YT-471B YT-474 YT-475A YT-475B NOTE 4 PUMP 2-4 LC-494D LI-494D LC-494H Ll-494H TE-407D T0472A TX-408D TX-409D TX-410D TX-411D TX-412D TE-495D T0474A TE-495H T0476A TE-496D T0473A TE-496H T0475A TE-495M SPARE TE-495Q SPARE TE-495U SPARE PC-497D PI-497D YT-480A YT-480B YT-481A YT-481B YT-484 YT-485A YT-485B UNIT 2 SEE DWG 502691 FOR CURRENT SLOT BEING MEASURED DIABLO CANYON POWER PLANT - PG&E CO, REACTOR COOLANT SYSTEM DRAWING SHEET PAGE REV 08007 SA 0 5 A

B C

D E