ML20262L363
From kanterella
Jump to navigation
Jump to search
ML20262L363 | |
Person / Time | |
---|---|
Site: | Catawba ![]() |
Issue date: | 06/08/1981 |
From: | DUKE POWER CO. |
To: | |
Shared Package | |
ML20030A712 | List:
|
References | |
CN-1609-2.0, NUDOCS 8107020108 | |
Download: ML20262L363 (1) | |
Similar Documents at Catawba | |
---|---|
Category:DRAWINGS
MONTHYEARML20266A5471996-02-14014 February 1996
[Table view]General Assembly Shaft Seal Pump ML20266A5341996-02-14014 February 1996 as Built.Sheet 2 of 2 ML20266A5301996-02-14014 February 1996 as Built.Sheet 1 of 2 ML20266A5161996-02-14014 February 1996 General Arrangement.Sheet 2 of 2 ML20265F4971996-02-14014 February 1996 Valve Assembly 8 Inch 600 LB Gate Valve Cressoh A-20.Sheet 1 of 1 ML20266A3791996-02-14014 February 1996 General Arrangement.Sheet 1 of 2 ML20266A2991996-02-14014 February 1996 General Arrangement Elevation Westinghouse Electric Corp 173 Feet Id PWR ML20265F5291996-02-14014 February 1996 Valve Assembly 4 Inch 1500 LB Gate Cres Sch 80.Sheet 1 of 1 ML20266A3101996-02-14014 February 1996 150 Gpm 7 Inch Dia LOW Pressure Filter Assembly Inside Out Flow.Sheet 1 of 1 ML20266A3191996-02-14014 February 1996 Tank 400 Ft Volume Control.Sheet 1 of 2 ML20266A3241996-02-14014 February 1996 Pulsation Damper Assy Reciprocating Suction Pump 1 Gallon. Sheet 1 ML20266A3051995-08-14014 August 1995 80 Gpm 4 Inch Dia High Pressure Filter Assembly Inside Out Flow.Sheet 1 of 1.Actual Drawing Number 5EHD-10602-004EC32 ML20265F6551995-06-26026 June 1995 Auxiliary Feedwater System to STM Gen 2D ML20266F8241995-06-13013 June 1995 as Built Dimensions.Sheet 2 of 3 ML20266F8211995-06-13013 June 1995 as Built Dimensions.Sheet 1 of 3 ML20266F8161995-06-13013 June 1995 as Built Dimensions.Sheet 2 of 3 ML20266F8111995-06-13013 June 1995 as Built Dimensions.Sheet 1 of 3 ML20266F8081995-06-13013 June 1995 General Arrangement.Sheet 2 of 2 ML20266A2221995-03-31031 March 1995 Flow Diagram of Main Steam System SM ML20266A5431995-03-20020 March 1995 as Built Dimensions Ddgt 1924.Sheet 1 of 3 ML20266A5391995-03-0303 March 1995 as Built Dimensions Ddgt 1923.Sheet 1 of 3 ML20266A5251995-03-0303 March 1995 as Built Dimensions DOST-1222.Sheet 1 of 3 ML20266A5211995-03-0303 March 1995 as Built Dimensions.Sheet 1 of 3 ML20266A2851995-02-25025 February 1995 Ddp as Builts Coordinates & Elevation of Closure Head Penetration.Sheet 7 of 9 ML20265F5021995-01-20020 January 1995 Valve Assembly Gate 6 Inch 150 LB Cres.Sheet 1 of 1 ML20266A1891994-12-0606 December 1994 Flow Diagram of Containment Spray System Ns ML20266A1851994-11-23023 November 1994 Flow Diagram of Safety Injection System Ni ML20265F5651994-11-0606 November 1994 Reactor Coolant System to Regen HX & Reac Coolant Drain Tank Pumps ML20265F7071994-10-25025 October 1994 Feedwater System to Steam Generator 2C ML20265F6391994-10-25025 October 1994 Auxiliary Feedwater Sys Aux Feedwater to Steam Gen 2C. Drawing Number Partially Illegible ML20266A4261994-10-10010 October 1994 Flow Diagram of Component Cooling System Kc ML20266A2011994-09-27027 September 1994 Flow Diagram of Feedwater System CF ML20262E9321994-09-14014 September 1994 General Arrangement ML20266A1501994-09-13013 September 1994 Flow Diagram of Chemical & Volume Control System Nv ML20266A4541994-09-13013 September 1994 Flow Diagram of Nuclear Service Water System Rn ML20266A1701994-09-0909 September 1994 Flow Diagram of Safety Injection System Ni ML20266A1751994-08-29029 August 1994 Flow Diagram of Safety Injection System Ni ML20266A2071994-08-22022 August 1994 Flow Diagram of Auxiliary Feedwater System CA ML20266A1611994-08-11011 August 1994 Flow Diagram of Residual Heat Removal System No ML20266A1411994-08-0909 August 1994 Flow Diagram of Chemical & Volume Control System Nv ML20266A1291994-08-0909 August 1994 Flow Diagram of Reactor Coolant System Nc ML20265F5241994-08-0909 August 1994 Valve Assy Gate 4 Inch 900 LB Cres with Motor Cpep Sch 80. Sheet 1 of 1 ML20266A1551994-08-0303 August 1994 Flow Diagram of Chemical & Volume Control System Nv ML20266A1371994-08-0303 August 1994 Flow Diagram of Chemical & Volume Control System Nv ML20266A1321994-07-27027 July 1994 Flow Diagram of Chemical & Volume Control System Nv ML20266A1661994-07-25025 July 1994 Flow Diagram of Residual Heat Removal System No ML20266A4621994-07-13013 July 1994 Flow Diagram of Nuclear Service Water System Rn ML20266A4691994-07-13013 July 1994 Flow Diagram of Nuclear Service Water System Rn ML20265F7121994-07-0202 July 1994 Feedwater Sys to Steam Gen 2D ML20265F6601994-07-0202 July 1994 Auxiliary Feedwater System to STM Gen 2B 1996-02-14 Category:DRAWINGS-PIPING & INSTRUMENTATION DIAGRAMS-APPLICANT'S MONTHYEARML20266A2631986-01-31031 January 1986
[Table view]Flow Diagram of Reactor Coolant System (Nc), as-built. Rev Date Illegible ML20266A1861986-01-31031 January 1986 Flow Diagram of Solid Radwaste System (Ws). Rev Date Illegible ML20266A1901986-01-31031 January 1986 Flow Diagram of Solid Radwaste System (Ws). Rev Date Illegible ML20266A2031986-01-31031 January 1986 Flow Diagram of Liquid Radwaste System (Wl), as-built.Rev Date Illegible ML20266A0791986-01-31031 January 1986 Flow Diagram of Makeup Demineralizer Water System (Ym). Rev Date Illegible ML20266A2111986-01-31031 January 1986 Flow Diagram of Liquid Radwaste System (Wl), as-built.Rev Date Illegible ML20266A0891986-01-31031 January 1986 Flow Diagram of Liquid Radwaste System (Wl), as-built.Rev Date Illegible ML20266A2161986-01-31031 January 1986 Flow Diagram of Liquid Radwaste System (Wl). Rev Date Illegible ML20266A2731985-07-12012 July 1985 Flow Diagram of Reactor Coolant System (Nc), as-built ML20266A2691985-07-12012 July 1985 Flow Diagram of Reactor Coolant System (Nc), as-built ML20266A0951985-07-12012 July 1985 Flow Diagram of Diesel Gen Engine Fuel Oil System (Fd), as-built ML20266A0981985-07-12012 July 1985 Flow Diagram of Diesel Gen Engine Fuel Oil System (Fd, as-built ML20266A2201985-07-12012 July 1985 Flow Diagram of Containment Spray System (Ns), as-built ML20266A1401985-07-11011 July 1985 Flow Diagram of Feedwater System (Cf) ML20198L7061985-07-0808 July 1985 Flow Diagram of Main Steam to Aux Equipment (SA) Main Steam Bypass to Condenser (Sb), as-built ML20266A1941985-06-11011 June 1985 Flow Diagram of Solid Radwaste System (Ws) ML20266A1171985-05-24024 May 1985 Flow Diagram of Main Turbine Leakoff & Steam Seal System (Tl) ML20266A1201985-05-24024 May 1985 Flow Diagram of Station Air System (Vs) ML20266A1351985-05-23023 May 1985 Flow Diagram of Heater Drain System (Hw) ML20261G3881985-05-17017 May 1985 Flow Diagram of Nuclear Sampling System (Nm), as-built.Rev Date Illegible ML20266A1441985-04-29029 April 1985 Flow Diagram of Steam Generator Blowdown System (88), as-built ML20266A1991985-04-11011 April 1985 Flow Diagram of Liquid Radwaste System (Wl) ML20266A1251985-03-12012 March 1985 Flow Diagram of Makeup Demineralized Water System (Ym), as-built ML20266A1731985-03-12012 March 1985 Flow Diagram of Nuclear Sampling System (Nm), as-built ML20266A1681985-03-12012 March 1985 Flow Diagram of Nuclear Sampling System (Nm), as-built ML20266A1311985-03-0707 March 1985 Flow Diagram of Fire Protection System (Rf) ML20266A1641985-02-21021 February 1985 Flow Diagram of Component Cooling System (Kc), as-built ML20266A2301985-02-12012 February 1985 Flow Diagram of Boron Recycle System (Nb), as-built ML20261G3761985-01-29029 January 1985 Flow Diagram of Waste Gas System (Wg), as-built ML20261G4081985-01-17017 January 1985 Flow Diagram of Auxiliary Feedwater System (Ca), as-built ML20266A1541985-01-0707 January 1985 Flow Diagram of Nuclear Service Water System (Rn), as-built ML20261G3571985-01-0707 January 1985 Flow Diagram of Boron Recycle System (Nb), as-built ML20266A1761985-01-0707 January 1985 Flow Diagram of Waste Gas System (Wg), as-built ML20266A1811985-01-0707 January 1985 Flow Diagram of Waste Gas System (Wg), as-built ML20266A2581985-01-0707 January 1985 Flow Diagram of Chemical & Volume Control System (Nv), as-built ML20266A2261985-01-0707 January 1985 Flow Diagram of Boron Recycle System (Ns), as-built ML20266A2351985-01-0707 January 1985 Flow Diagram of Boron Recycle System (Nb), as-built ML20266A2391985-01-0707 January 1985 Flow Diagram of Boron Thermal Regeneration System (Nr), as-built ML20266A2431985-01-0707 January 1985 Flow Diagram of Boron Thermal Regeneration System (Nr), as-built ML20266A2461985-01-0707 January 1985 Flow Diagram of Chemical & Volume Control System (Nv), as-built ML20266A1491985-01-0707 January 1985 Flow Diagram of Nuclear Service Water System (Rn), as-built ML20266A2551985-01-0707 January 1985 Flow Diagram of Chemical and Volume Control System (Nv), as-built ML20266A2501985-01-0707 January 1985 Flow Diagram of Chemical and Volume Control System (Nv), as-built ML20261G4261984-12-11011 December 1984 Flow Diagram of Reactor Coolant System (Nc), as-built ML20261G3931984-12-11011 December 1984 Flow Diagram of Nuclear Sampling System (Nm), as-built ML20261G4211984-11-29029 November 1984 Flow Diagram of Conventional Chemical Addition System (Ya) ML20261G3591984-11-15015 November 1984 Flow Diagram of Liquid Radwaste System (Wl) ML20261G3851984-11-14014 November 1984 Flow Diagram of Nuclear Sampling System (Nm), as-built ML20261G3681984-11-14014 November 1984 Flow Diagram of Liquid Radwaste System (Wl) ML20261G4041984-11-13013 November 1984 Flow Diagram of Auxiliary Feedwater System (Ca), as-built 1986-01-31 |
Text
Retrieved from "https://kanterella.com/w/index.php?title=ML20262L363&oldid=3132381"