f() k U l4/tW W (f

h.fr k

1

.M PRELIMINARY NOTIFICATION m

[

)

April 14,1978

~

PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-78-79A This preliminary notification constitutes EARLY notice of an event I

of POSSIBLE safety or public interest significance.

The information preser.ted is as initially received without verification or evaluation and is bas _.ically all that is known by IE staff as of this date.

FACILITY:

Duke Power Company Oconee, Unit Nos. 1, 2 and 3 l

DNS 50-269, 50-270 and 50-287 Oconee County, South Carolina

SUBJECT:

ERROR IN SMALL BREAK ANALYSIS OF REACTOR COOLANT SYSTEM This supplements and corrects preliminary information provided in PN0 78-79 dated April 13, 1978.

The B&W reanalysis assumed a pipe break of 0.04 square feet, which is the worst case, in the reactor coolant pump discharge piping.

This size l

l break apparently does not result in a reactor coolant system *(RCS)

~

O pressure decrease sufficient to cause the low pressure injection (LPI) j w"

((gl and core flood (CF) systems to function properly.

The original analysis

(

)

was for a pipe break of 0.1 square feet which resulted in the RCS being depressurized and water being supplied by the LPI and CF systems.

s Media interest has not occurred. A ners release is e t planned by the licensee nc. NRC.

The State of South Carolina has been notified.

I Region 11 (Atlanta) received notification of this updated information by telephone from the licensee at 3:00 p.m. on April 13.

Contact:

GKlingler, IE x28019 FNolan, IE x28019 Distribution:

Transmitted H St/d! N Chairman Hendrie Commissioner Bradford Commissioner Kennedy S. J. Chilk, SECY C. C. Kammerer, CA Commissioner Gilinsky (For Distribution) j Transmitted:

MNBB /ol d P Bldg /d ** I '

E. Volgenau

/

Region 2Z~~, IE/4.'3b L. V. Gossick, EDO E. G. Case, NRR i

S. H. Hanatar, EDO J. J. Fouchard, PA SSBldg/d!3 f (MAIL) l R. Hartfield, MIPC C. V. Smith, NMSS T. J. McTiernan, DIA R. G. Ryan, OSP R. Minogue, SD H. K. Shapar, ELD PRELIMINARY NOTIFICATION y:.

9006100365 780414 fNO-73 79A PDR

.