ML20248K416

From kanterella
Jump to navigation Jump to search

Discusses Completion of Licensing Action for GL 97-04, Assurance of Sufficient Net Positive Suction Head for ECC & Containment Heat Removal Pumps, Issued on 971007
ML20248K416
Person / Time
Site: McGuire, Mcguire  
Issue date: 06/05/1998
From: Rinaldi F
NRC (Affiliation Not Assigned)
To: Barron H
DUKE POWER CO.
References
GL-97-04, GL-97-4, TAC-MA0007, TAC-MA0008, TAC-MA7, TAC-MA8, NUDOCS 9806100110
Download: ML20248K416 (4)


Text

We -561 Artig

,s 4

p 4 '4 ONITED STATES j

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C 10666 4001 June 5, 1998 Mr. H. B. Barron Vice President, McGuire Site Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, North Carolina 28078-8985

SUBJECT:

COMPLETION OF LICENSING ACTION FOR GENERIC LETTER 97 MCGUIRE NUCLEAR PLANT, UNITS 1 AND 2 (TAC NOS. MA0007 AND MA0008)

Dear Mr. Barron:

The U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 97-04, " Assurance of Sufficient Net Positive Suction Head for Emergency Core Cooling and Containment Heat Removal Pumps," to all holders of operating licenses or construction permits on October 7, 1997. The NRC issued GL 97-04 to confirm the adequacy of the net positive suction head (NPSH) available for emergency core conting (including core spray and decay heat removal) and containment heat removal pumps under all design-basis accident scenarios, in GL 97-04, the NRC staff specifically requested that licensees provide the information outlined -

below for each of their facilities.

1. Specify the general methodology used to calculate the head loss associated with the ECCS suction strainers.
2. Identify the required NPSH and the available NPSH.
3. Specify whether the current design-basis NPSH analysis differs from the most recent analysis reviewed and approved by the NRC for which a safety evaluation was issued.
4. Specify whether containment overpressure (i.e., containment pressure above the vapor pressure of the sump or suppression pool fluid) was credited in the calculation of available NPSH, Specify the amount of overpressure needed and the minimum overpressure available.
5. When containment overpressure is credited in the calculation of available NPSH, confirm k g that an appropriate containment pressure analysis was done to establish the minimum j

containment pressure, Di p j c

l

)

m n

,u-9906100110 900605 PDR ADOCK 05000369 i

P PDR l

a=

y fr.

L 2-June 5,' 1998 H. B. Barron in response to GL 97-04, you provided letter dated January 5,1998, for McGuire Nuclear.

Station, Units 1 and 2. The submittels provided the information requested by GL 97-04. The

' staff has reviewed your response and has concluded that all requested information has been -

provided; therefore, we consider GL 97-04 closed for your facility. We appreciate your prompt and complete response.

If you have any questions regarding this matter, please contact Frank Rinaldi at 301-415-1447.

Sincerely, ORIGINAL SIGNED BY:

Frank Rinaldi, Project Manager Project Directorate 11-2 Division of Reactor Projects - 1/ll Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50-370 cc: See next page -

DISTRIBUTION.

Docket File PUBLIC PD 11-2 Reading File -

JZwolinski HBerkow OGC FRinaldi LBerry ACRS LPlisco, Rll t

DSkay, Lead PM -

JKudrick, NRR KKavanagh, NRR COgle, Ril DOCUMENT NAME: G:\\MCGUIRE\\9704.LTR To receive a copy of this document, indicate in the box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy *See previous concurrence

//

LA:PDil-2*

SRXB:NRR*

SCSB:NRR*

Plf91jpG-2 OFFICE - PM:PDll-2 ',,.s NAME FRinaldi:cn QP LBerry RCaruso JKudrick

@qP 6/5/98 6/5/98 5/f/96 DATE' 6 /f/98

[-

6/1/98 OFFICIAL RECORD COPY-1

.L

)

/

=

a H.B.Banon t in response to GL 97-04, you provided letter dated January 5,1998, for McGuire Nuclear Station, Units 1 and 2. The submittal provided the information requested by GL 97-04. The staff has reviewed your response and has concluded that all requested information has been provided; therefore, we consider GL 97-04 closed for your facility. We appreciate your prompt and complete response.

If you have any questions regarding this matter, please contact Frank Rinaldi at 301415-1447..

Sincerely, Frank Rinaldi, Project Manager Project Directorate 11-2 Division of Reactor Projects -l/II Office of Nuclear Reactor Regulation Docket Nos. 50 369 and 50-370 cc: See next page

j McGuire Nuclear Station cc:

Mr. Paul P.. Newton Ms. Karen E. Long Legal Department (PBO5E)

Assistant Attorney General Duke Energy Corporation North Carolina Department of 422 South Church Street Justice Charlotte, North Carolina 28242 P. O. Box 629 Raleigh, North Carolina 27602 County Manager of Mecklenburg County L. A. Keller 720 East Fourth Street Manager-Nuclear Regulatory Charlotte, North Carolina 28202 Licensing Duke Energy Corporation Michael T. Cash 526 South Church Street Regulatory Compliance Manager Charlotte, North Carolina 28242 Duke Energy Corporation McGuire Nuclear Site Regional Administrator, Region ll 12700 Hagers Ferry Road U.S. Nuclear Regulatory Commission Huntersville, North Carolina 28078 Atlanta Federal Center j

61 Forsyth Street, S.W., Suite 23T85 J. Michael McGarry, Ill, Esquire Atlanta, Georgia 30303 Winston and Strawn 1400 L Street, NW.

Elaine Wathen, Lead REP Planner Washington, DC 20005 Division of Emergency Management 116 West Jones Street Senior Resident inspector Raleigh, North Carolina 27603-1335 clo U.S. Nuclear Regulatory Commission Mr. Richard M. Fry, Director 12700 Hagers Ferry Road Division of Radiation Protection Huntersville, North Carolina 28078 North Carolina Department of Environment, Health and Natural Mr. Peter R. Harden, IV Resources Account Sales Manager 3825 Barrett Drive I

Westinghouse Electric Corporation Raleigh, North Carolina 27609-7721 Power Systema Field Sales P. O. Box 7288 Mr. T. Richard Puryear Charlotte, North Carolina 28241 Owners Group (NCEMC)

Duke Energy Corporation Dr. John M. Barry 4800 Concord Road Mecklenberg County York, South Carolina 29745 Department of Environmental Protection 700 N. Tryon Street Charlotte, North Carolina 28202 I

I t

m