,.,-t' September 15, 1939 DISTRIBUTION Docket Nos. 50-334 Docket Jsle Gray File 50-412 NRC & Local PDRs E. Murphy S. Varga L. Engel Mr. J. D. Sieber. Vice President B. Boger Nuclear Group S. Norris Duquesne Light Company P. Tam Post Office Box'4-OGC Shippingport,PA 15077 E. Jordan B. Grimes
Dear Mr. Sieber:
ACRS(10)
SUBJECT:
BEAVER VALLEY l and 2 - WESTINGHOUSE STEAM GENERATOR MECHANICAL PLUGS (TAC 73146 and 73147)
We have. completed review ofryour June 16, 1989 response to Bulletin 89-01,
" Failure of Westinghouse Steam Generator Tube Mechanical Plugs". We find your response consistent with Actions Requested items 2, 3 and 4, but noted that for item 2b you have not specifically committed to perform any action for refueling outages beyond 1989. In the absence of specific information to the contrary,' we assume that a commitment is implicit in your reply to item 2b. Please advise us if this assumption is not correct.
This completes,our efforts on the subject. bulletin for Beaver Valley.
Sincerely, Signed by l
Peter S. Tam, Senior Project Manager l
Project Directorate I-4 Division of Reactor Projects I/II l
l a
9210099 spopy, ADOCK 05coggg4 Q
PDC LA:PDI-4 PM:PD 4 PD :PDI-4 S1 orris PTam JStolz 9/ /89 9//f/
9//5789 /
l.
l
p.~
p l
I:
, '. Mr. 'J. Sieber Beaver Valley Power Station l
' Duquesne light Company Units 1 & 2 cc:
Jay E. Silberg, Esquire Bureau of Radiation Protection Shaw, Pittman, Potts and Trowbridge Pennsylvania Department of 2300 N Street, N.W.
Environmental Resources Washington, DC 20037 ATTN:
R. Janati Post Office Box 2063 Kenny Grada, Manager Harrisburg, Pennsylvania 17120 Nuclear Safety Duquesne Light Company Mayor of the Borrough of i
P. O. Box 4 Shippingport L
Shippingport, Pennsylvania 15077 Post Office Box 3 Shippingport, Pennsylvania 15077 l
John A. Lee, Esquire Ashley C. Schannauer Duquesne Light Company Assistant City Solicitor One Oxford Centre City of Pittsburgh 301 Grant Street 313 City-County Building Pittsburgh, Per.nsylvania 15279 Pittsburgh, Pennsylvania 15219 Roy M. Smith, Connissioner Regional Administrator, Region I Department of Labor U.S. Nuclear Regulatory Comissien Bldg. 3, Room 319, Capitol Complex, 475 Allendale Road Charleston, West Virginia 25305 King of Prussia, Pennsylvania 19406 John D. Borrows P.esident Inspector Director, Utilities Department U.S. Nuclear Regulatory Comission Public Utilities Connission Post Office Box 181 180 East Broad Street Shippingport, Per.nsylvania 15077 Columbus, Ohio 43266-0573 Director, Pennsylvania Emergency l
Management Agency Post Office Box 3321 Harrisburg, Pennsylvania 17105-3321
- _ - - _ _ _ _