... PLANT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued)

b. The control room exhaust subsystem isolation damper (s) close, and.the exhaust fan trips off;
c. The control room emergency makeup air and filtration subsystem actuates with flows through the HEPA filters and charcoal adsorber banks;
3) Verifying that upon generation of Remote Intake High Radiation test signal, the following automatic system functions occur:
a. The normal makeup air fan (s) trip off and the normal makeup air isolation damper (s) close;
b. The control room exhaust subsystem isolation damper (s) close, and the exhaust fan trips off;
c. The control room emergency makeup air and filtration subsystem actuates with flows through the HEPA filters and charcoal adsorber banks;
4) Verifying that-the Control Room Emergency Makeup Air and Filtration Subsystem maintains the control room at a positive '

pressure of greater than or equal to 1/8 inch Water Gauge at less than or equal to a pressurization flow of 600 cfm relative -

toadjacentareasduringsystemoperation;and

5) Verifying that the heaters dissipate 3.6 i 0.36 kW when tested in accordance with ANSI N510-1980 g
f. After each complete.or partial replacement of a HEPA filter bank, by verifying that the filtration system satisfies the in place penetration and bypass leakage testing acceptance criteria of less than .05% in accordance with ANSI N510-1980 for a 00P test aerosol while operating the system at a flow rate of 1100 cfm 10%; and
g. After each complete or partial replacement of a charcoal adsorber bank, by verifying that the filtration system satisfies the in place penetration and bypass leakage testing acceptance criteria of less than .05% in accordance with ANSI N510-1980 for a halogenated hydrocarbon refrigerant test gas while operating the system at a flow rate of 1100 cfm i 10%.