Responds to NRC Re Violations Noted in Insp Rept 50-395/89-15.Violations Denied.Verification of Remote Position Indicators at Main Control Board Performed
ML20247H914
Person / Time
Site: Summer 
Issue date: 09/13/1989
From: Bradham O
SOUTH CAROLINA ELECTRIC & GAS CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 8909200144
Download: ML20247H914 (3)


Text

_ _ _. - __

10CFR2.201 Olli S.

ridhtm uth tina ElIctric & GIs Comp 2ny Jenkinsville, SC 29065 Nuclear Operations (803) 3454040 l

SCE&G m

s.,

September' 13, 1989

-o?

Document Control Desk

-U. S. Nuclear Regulatory Commission Washington, DC-20555

SUBJECT:

Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 Response to Notice of Violation NRC Inspection Report 89-15 Gentlemen:

Attached is the South Carolina Electric & Gas Company (SCE&G) response to the Notice of. Violation (NOV) dated August 18, 1989. Attachment 1 to this letter is the SCELG " Response to Notice of Violation" (see 10 CFR 2.201).

SCE&G disagrees that a violation occurred as described in paragraph 2b of the y.

Inspection Report. As indicated during the exit meeting, SCE&G does not agree that the' violation described in the Inspection Report occurred.

In sum, SC&EG L

believes that there has been misinterpretation of subsection IWV-3300 of the.

ASME Code in relation to testing of valves with remote position indicators.

If you should have any questions, please advise.

Very truly yours,

[

W

0. S. Bradham HID/OSB: led Attachment c:

D. A. Nauman/0. W. Dixon, Jr./T. C. Nichols, Jr.

E. C. Roberts W. A. Williams, Jr.

J. C. Snelson S. D. Ebneter R. L. Prevatte L

J. J. Hayes, Jr.

J. B. Knotts, Jr.

General Managers NPCF C. A. Price NSRC R. B. Clary-RTS (IE 891501)

K. E. Nodland File (815.01) 89o9200144 epop13 gDR ADOCK 05000395 i

)

PDC j

s.;

-j

Attachment lito~ Document Control Desk letter

" '-&g September 13, 1989 LPage 1 of 1 1

RESPONSE TO NOTICE OF VIOLATION VIOLATION NUMBER 50-395/89-15-01 l

I.

RESTATEMENT 0F VIOLATION l

i

-Technical Specification 4.0.5 requires inservice testing of ASME Code l

Class 1, 2, and 3 pumps and valves in accordance with Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda..The licensee'is committed to inservice testing in accordance with the 1980 Edition of the Code and Winter Addenda.

Section XI, Subsection IWV-3300 of the 1980 Code, requires valves with remote position indicators to be observed at least once every 2 years i

to verify that valve operation is accurately indicated.

j Contrary to the above, verification of remote position indicators at.

the remote shutdown panels was not being performed.

i l

II.

SCE&G POSITION ON VIOLATION l

l SCE&G denies the violation.

l 1

III.

BASIS FOR SCE&G POSITION This violation is based.on Subsection IWV-3300 of the 1980 ASME Code j

that requires that valves with remote position indicators be observed

'I at least once every two years to verify that valve operation is

~

accurately indicated. Contrary to the violation, SCE&G satisfies this requirement in its Inservice Test Program (IST) by verifying accurate position indication at the main control board.. SCE&G performs a 1

periodic channel check of the shutdown panel instrumentation; however, the IST need not call for verification of the remote position indication every two years at the shutdown panel.

)

SCE&G's compliance with Section XI, Subsection IWV-3300 of the 1980 ASME Code is demonstrated by a recent interpr'tation addressing this precise issue. Under the recent interpreta+.an, Subsection IWV-3300 l

requires that "for valves having remote position indication at multiple locations (such as in the control room and also on a remote shutdown l

panel...)...only the remote position indicator at the location utilized in exercising the valve (IWV-3413)" need be verified.

(Interpretation XI-1-89-10, issued November 14, 1988; copy attached.) The licensee's IST meets this interpretation and therefore complies with the intent of l

Section XI, Subsection IWV-3300 of the 1980 Code and complies with i

Technical Specification 4.0.5.

)

I l

2-1 1. Attachment II to Document Control' Letter-n.:

. September 13, 1989'

+

. Page 1 of 2 t.

SECTION XI L

l Subject interpretation File No.

Division 1 Appendix ill, 111-3310; Calibration Confirmation-Period of Use (1977 Edition With Addenda Through Winter 1979....

XI-1-89-05 IN88 005 Code Case N-408; Alternate Rules for Examination of Class 2 Piping..

XI 1-89-03 lN88-003 IWA-2200; Edition and Addr nda of Section V Used With Section XI (1986 Edition With the 1987 Addenda).

XI 1-89-02 (N88-001 IWA 2232 and Code Case N-98; Calibration Block Tolerances (1977 Edition With Addenda Through Summer 1978)-

XI-1-89-09 LN87-Ol9 IWA 2300; Required Time for Testing - SNT.TC 1 A (1986 Edition With the 1986 Addenda)..

XI-1-89-06 IN88-006 IWA-4210 and IWA-4300; Welding Qualifications for Repairs (1986 Edition With the 1986 Addenda)....

Xl-1-89-01 IN87-036 IWAllWB/lWC/ LWD-5000; Pressure Test Requirements for Replacement of Nuts, Bolts, and Studs...

XI 189-08 lN87-018 lWA 7210; Transfer of Custody of Spare and Replacement Parts (1983 Edition and later Edition and Addenda Through the 1987 Addenda).

XI t-89-07 IN88 011 IWA 7400(d); NPS I and Less Exempted From Requirements (1977 Edition.

and Later Editions and Addenda Through the 1986 Editioni.

XI-189-04 IN88-004 IWV 3300, IWV.3412 and lWV-3413; Valve Exercising Test..

XI 1-89-10 IN88415 c Division 3 Table IM8-2500-1, IM8-5000, and IMC.2500; Accessibility-Double Enveloped System (1986 Edition)..

XI-3 89-01 IN86-024C l

l 163