Grants Util 861110 & 870604 Requests for Relief from First 10-yr Inservice Insp Program Requirements,Per 10CFR50.55a(g)(6)(i).EGG-ESM-7916, ...Rept on First 10-Yr Interval Inservice Insp Relief Requests:Cp&L..., Encl
ML20246B716
Person / Time
Site: Brunswick  
Issue date: 06/28/1989
From: Le N
Office of Nuclear Reactor Regulation
To: Eury L
CAROLINA POWER & LIGHT CO.
Shared Package
ML20246B719 List:
References
TAC-64742, TAC-64743, NUDOCS 8907100072
Download: ML20246B716 (4)


Text

r-q w.

4 j.a rrog'o UNITED STATES

~g f

g NUCLEAR REGULATORY COMMISSION a,.

r,,

,E WASHINGTON, D. C. 20555 June 28, 1989 Docket Nos. 50-325 50-324 Mr. Lynn W. Eury Executive Vice President Power Supply Carolina Power & Light Company Post Office Box 1551 Raleigh, North Carolina 27602

Dear Mr. Eury:

SUBJECT:

FIRST TEN-YEAR INTERVAL INSERVICE INSPECTION PROGRAM RELIEF REQUEST -

f BRUNSWICK STEAM ELECTRIC PLANT, UNITS 1 AND 2 (TAC NOS. 64742/64743) l By letter dated November 10, 1986, Carolina Power & Light Company (CP&L) submitted adescriptionofthein-serviceinspection(ISI)programforthesecond10-year interval of operation for the Brunswick Steam Electric Plant (BSEP), Units 1 and 2.

Included in this submittal were requests for relief from both the first and second 10-year intervals. On April 3, 1987, the NRC staff requested additional information by two separate letters; one concerning the first interval relief requests, and the other concerning the second interval program and relief requests.

By letter dated Jure 4,1987, CP&L submitted a response to the staff' request related to the first 10-year ISI interval relief request. The ISI Program Plan and information related to the second 10-year relief request were submitted on August 19, 1987 and October 19, 1987.

The staff, with the assistance of its contractors, Idaho National Engineering 4

Laboratory (INEL), reviewed the program, and the request for relief from the

)

ASME Code,Section XI, requirements which CP&L has determined to be impractical.

{

l Yhe staff has reviewed the evaluation reports from INEL, and has found that CP&L l

has demonstrated that certain Code requirements are impractical, the proposed alternatives would provide an acceptable level of quality and safety, and that com)liance with the requirements would result in hardships or unusual difficulties

)

witicut a compensating increase in the level of quality ano safety.

l In accordance with the requirements of 10 CFR 50.55a(g), the staff concludes that the CP&L determination under 10 CFR 50.55a(g)5 that Code requirements are i

impractical is acceptable. Therefore, all relief requests for the first 10-year l

ISI program requested in CP&L letter of November 10, 1986, as supplemented in June 4, 1987 are granted. The staff has determined, pursuant.to 10 CFR Part 50.55a(g)(6)(i), that the granting of these reliefs is authorized by law and will not endanger life or property or the comon defense and security and is i

otherwise in the public interest.

In making this determination, the staff has

)

given due consideration to the burden that could result if these requirements j

were imposed on the licensee.

l OPl l

8907100072 890628 f

l l

DR ADOCK 0500 3 4 j

i

.s,.

Mr. Lynn W., Eury.

Enclosure I contains a detailed evaluation from the NRC contractor, INEL, of' the BSEP's first 10-year ISI relief request. The staff has reviewed this evaluation and concurs with, and adopts, its findings and conclusions.

Staff evaluation of the CP&L's revised second 10-year ISI and related relief request were transmitted to you by our letter dated May 10, 1989, i

k Ngoc B. Le, Project Manager Project Directorate 11-1 Division of Reactor Projects -I/II Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ encl:

See next page I

F

w,..

(

Mr. - Lynn W. Eury Enclosure 1 contains a detailed evaluation from the NRC contractor, INEL, of

'the BSEP's first 10-year ISI relief request. The staff has reviewed this-

. evaluation and concurs with, and adopts, its findings and conclusions.

Staff evaluation of the CP&L's revised second 10-year ISI?and related relief '

request were trant,mitted to you by our letter dated May 10, 1989.

Original sigried by:

Ngoc B. Le, Project Manager Project Directorate 11-1 Division of Reactor Projects -1/11 Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ encl:

See next.page DISTRIBUTION Docket Fileg NRC PDRP ~ "

Local PDR PDII-I Reading S. Yarga 14-E-4 G. Lainas 14-H-3 E. Adensam 14-B-20 P. Anderson 14-B-20 H. Le 14-B-20 OGC (For -inform. Only) 15-B-18 E. Jordan MNBB-3302 B. Grimes 9-A-2 L. Spessard MNBB-3701 CYCHen 9-H-15 ACRS(g) 10 P-315 BRUNSWICK FILE

  • SEEPREVIOUSCONCURRENCES LA:PDII-1 PM:PDII EMTB 0

D:PD:II-1 PAnderson NLe:sw T4.-

CYCheng i/89 ijEAdensam' (#

6/h/89 6/23/89 6/ /89 6

6/d'/89

~

~

i g g.

Mr. L. W. Eury Brunswick Steam Electric Plant Carolina Powcr & Light Company Units I and 2 cc:

Mr. Russell B. Starkey, Jr.

Mr. H. A. Cole Project Manager Special Deputy Attorney General Brunswick Nuclear Project State of North Carolina P. O. Box 10429 P. O. Box 629 Southport, North Carolina 28461 Raleigh, North Carolina 27602

)

Mr. R. E. Jones, General Counsel Mr. Robert P. Gruber Carolina Power 5 Light Company Executive Director P. O. Box 1551 Public Staff - NCUC Raleigh, North Carolina 27602 P. O. Box 29520 Raleigh, North Carolina 27626-0520 Ms. Grace Beasley Board of Commissioners P. O. Box 249 Bolivia, North Carolina 28422 Resident Inspector U. S. Nuclear Regulatory Commission Star Route 1 P. O. Box 208 Southport, North Carolina 28461 Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, Suite 2900 Atlanta, Georgia 30323 Mr. Dayne H. Brown, Chief Radiation Protection Branch Division of Facility Services N. C. Department of Human Resources 701 Barbour Drive Raleigh, North Carolina 27603-2008 Mr. J. L. Harness Plant General Manager Brunswick Steam Electric Plant P. O. Box 10429 Southport, North Carolina 28461 i