ML20246B613

From kanterella
Jump to navigation Jump to search

Forwards Amend 25 to License NPF-62 & Safety Evaluation. Amend Revises Tech Spec Table 3.3.2-1,providing Addl Info Re Channel Configuration for Main Steam Line Turbine Bldg Temp High Trip Channels
ML20246B613
Person / Time
Site: Clinton 
Issue date: 08/17/1989
From: John Hickman
Office of Nuclear Reactor Regulation
To: Holtzscher D
ILLINOIS POWER CO.
Shared Package
ML20246B618 List:
References
TAC-69550, NUDOCS 8908230411
Download: ML20246B613 (3)


Text

60 4

August 17, 1989 Docket No. 50-461 DISTRIBUTION

^

Docket file NRC & Local PDRs PDIII-2 r/f MVirgilio Mr. Dale L. Holtzscher LLuther JHickman Acting Manager - Licensing and Safety OGC DHagan Clinton Power Station EJordan TEeek (4)

P. O. Box 678 WJones JCalvo Mail Code V920 ACRS(10)

GPA/PA Clinton, Illinois 61727 OC/LFMB Plant file

Dear Mr. Holtzscher:

SUBJECT:

TECHNICAL SPECIFICATION CHANGE REQUEST TO ADD A NOTE REGARDING THE CHANNEL CONFIGURATION FOR THE MAIN STEAM l

LINE TURBINE BUILDING TEMPERATURE TRIP CHANNELS l

(TAC NO. 69550) l l

RE:

Clinton Power Station, Unit No. 1 The Commission has issued the enclosed Amendment No. 25 to Facility Operating l

License No. NPF-62 for the Clinton Power Station, Unit No. 1.

This amendment l

consists of changes to the Technical Specifications (TSs) in response to your l

application dated May 18, 1988.

This amendment revises Technical Specification Table 3.3.2-1 to add a note prcsiding aoditional information regarding the channel configuration for the Main Ste6m Line (MSL) Turbine Building Temperature - High trip channels.

A copy of our Safety Evaluation is also enclosed. Notice of Issuance will be included in the Commission's biweekly Federal Register notice.

Sincerely,

/s/

John B. Hickman, Project Manager Project Directorate III-2 Division of Reactor Projects III, IV, V, and Special Projects Office of Nuclear Reactor Regulation spg

Enclosures:

-o o.

1.

Amendment No. 25 to

$8 License No. NPF-62 gg 2.

Safety Evaluation OfA

~;l5 gg cc w/ enclosures:

gc See r. ext page O

a.a.

PDIII-2:LA DIII-2:PM r'

PDIII-2:(A)PD OGCy LLuther:dmjg JMickman PShemanski 7/J//89 7/RS/89 7/, /89 7/ } /89

{

y

' 'gil*;

32 tico

[o

'g UNITED STATES

'[

g-NUCLEAR REGULATORY COMMISSION l? si q 7,; *-

E

- WASHINGTON, D. C. 20555

}^

o

%,.....+/

August 17, 1989 Docket No. 50-461-Mr.' Dale L. Holtzscher Acting Manager - Licensing and Safety Clinton Power Station P. D. Box 678 Mail Code V920 Clinton, Illinois 61727

Dear Mr. Holtzscher:

SUBJECT:

TECHNICAL SPECIFICATION CHANGE REQUEST TO ADD A NOTE REGARDING THE CHANNEL CONFIGURATION FOR THE MAIN STEAM LINE TURBINE BUILDING TEMPERATURE TRIP CHANNELS (TACNO.69550)

RE:-

Clinton Power Station, Unit No. 1 The Commission has issued the enclosed Amendment No. 25 to Facility Operating.

License No. NPF-62 for the Clinten Power Station, Unit No. 1.

This amendment consists of changes to the Technical Specifications (TSs) in response to your application dated May 18, 1988.

~

This amendment revises Technical Specification Table 3.3.2-1 to add a note providing additional information regarding the channel-configuration for the Main. Steam Line (MSL) Turbine Building Temperature - High trip channels.

A copy of cur Safety Evaluation is also enclosed. Notice of Issuance will be included in the Commission's biweekly Federal Register notice.

Sincerely, NWi John B. Hickman, Project Manager Project Directorate III-2 Division of Reactor Projects III, IV, V, and Special Projects Office of Nuclear Reactor Regulation

Enclosures:

1.

Amendment No. 25 to License No. NPF-62 2.

Safety Evaluation cc w/ enclosures:

See next~page u.---_____.

r --

fy u.

It Dale L. Holtzscher-Clinton Power Station Illinois Power Company Unit I

+-

cc:

1 Mr. D. P Hall Illinois Department Senior Vice President of Nuclear Safety Clinton' Power. Station Division of Engineering

~P. O. Box 678 1035 Outer Park Drive, 5th Floor Clinton, Illinois, 61727 Springfield, Illinois 62704 Mr. R. D. Freeman Mr. Donald Schopfer

~ Manager-Huc', ear Station Engineering Dept.

Project Manager Clinton Power Station Sargent & Lundy Engineers P. O. Box 678 55 East Monroe Street

-Clinton, Illinois 61727 Chicago, Illinois 60603 Shelden Zabel, Esquire Schiff, liardin & Waite 7200 Sears Tower.

233 Wacker Drive Chicagc, Illinois 60606 Resident Inspector U. S. Nuclesr Regulatory Commission RRf3, Box 229 A Clinter. Illinois 61727 Mr. L. Larson.

Project Manager

. General Electric Company 175 Curtner Avenue, N/C 395 Sen Jose, Californie 95125 Regional-Administrator, Region III 799 Roosevelt Road, Bldg. f4 Glen Ellyn, Illinois 60137 Chairman of DeWitt County c/o County Clerk's Office DcWitt County Courthouse Clinton, Illinois 61727

_