ML20245H622

From kanterella
Jump to navigation Jump to search
Safety Evaluation Supporting Amend 16 to License NPF-73
ML20245H622
Person / Time
Site: Beaver Valley
Issue date: 04/26/1989
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20245H619 List:
References
NUDOCS 8905030453
Download: ML20245H622 (5)


Text

i

@ CIQp' o

UNITED STATES g

r]

g NUCLEAR REGULATORY COMMISSION 7.

j WASHINGTON, D. C. 20655

%,...../

I SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR PEGULATION RELATED TO AMENDMENT NO. 16 TO FACILITY OPERATING LICENSE NO. NPF-73 DUOVESNE LIGHT' COMPANY

)

OHIO EDISON COMPANY THE CLEVELAND ELECTRIC ILLUMINATING COMPANY g

THE TOLEDO EDISON COMPANY BEAVER VALLEY POWER STATION, UNIT N0. 2 i

DOCKET NO. 50-412 INTRODUCTION On August 14, 1987, we issued Facility Operating License NPF-73 to Duquesne Light Company (the licensee, acting as agent for the above utilities) for Beaver Valley Power Station Unit 2.

Included in the license are five time-sensitive license conditions, all of which required completion of certain activities according to their respective schedules.

1 By' letter dated January 30, 1989, the licensee requested that the completion I

schedules of three of these conditions be extended by the duration of one fuel cycle (approximately 18 months). By letters dated March 9 and April 19, 1989, the licensee submitted supplemental information on the request. We have completed review of that request and results are as follows.

DISCUSSION AND EVALUATION (1) Condition 2.C(7), Plant Safety Honitoring System (PSMS)

The licensee has satisfied the first ptrt of this condition regarding submittal of the PSMS verification and validation (V&V) plan by its submittal dated December 10, 1987.

The condition also requires that the approved V&V plan be implemented before start-up after the first refueling outage. The licensee stated that implementation of the V8V plan is largely complete, with full implementation scheduled to occur before startup after the first refueling outage. However, NRC audit of the V&V plan only occurred recently (January 31 thru February 2,1989), and results of the audit would be transmitted in the near future.

Due to this lateness, the licensee i

l

. does not have enough time to modify the V&V plan according to NRC-imposed requirements, and still meet the schedule imposed by this condition.

Accordingly, the licensee requested that full implementation be postponed from the first refueling outage to the second.

Based on the facts that (1) our onsite audit of the licensee's V&V plan uncovered no glaring shortcomings, (2) that almost all variables have diverse instrurrentation that is either independent or redundant from the PSMS and is available on the control boards (see SSER-6, NUREG-1057 Supplement 6), and (3) the licensee's best-faith efforts to implement the V V plan, we conclude that the requested delay will have no negative impact on overall plant safety. The implementation is thus acceptable.

I (2) Condition 2.C(S), Detailed Control Room Design Review (DCRDR)

The licensee stated that all DCRDR evaluation process activities are complete. Over 270 human engineering discrepancies (HEDs) were identified and documented (letters to NRC, December 2,1985 and January 8, 1987); most of these have been implemented or will be implemented before startup from the first refueling outage.

Thus, all DCRDR work will be completed, except the HEDs specified in Table 1.

The requested extension of the duration of one fuel cycle only covers these HEDs.

The licensee provided justification for the delayed implementation of these in its March 9, 1989 letter.

In general, these have low safety significance, or do not have any direct impact on normal

(

or post-accident plant operation.

We find the proposed extension of condition 2.C(8) to accommodate completion of the HEDs specified in Table 1 acceptable.

(3) Condition 2.C(9), Safety Parameter Display System (SPDS)

In a letter dated June 8, 1988, the licensee responded to NRC concerns addressed in Section 18.2 of Supplement 6 to the BVPS-2 Safety Evaluation Report (SSER-6). The licensee's responce provided justifications for issues requested by the NRC, clarified certain assumptions made by the NRC which were not completely accurate, and identified resolution activities which were either completed or scheduled to be completed prior to start-up following the first refueling outage. Thus, the bulk of the required work will be completed according to the current schedule imposed by this condition.

However, all system faults identified through site acceptance testing and the final response time testing are not expected to be resolved prior to start-up folicwing the first refueling outage. Some of these deficiencies or faults include failure to meet the specification response l

l l

. time criteria, the system idle time goes to zero (specification requires greater than 30%), the lack of sufficient printer buffer capacity to support the correct printout of a large cuantity of data, and a programming capability which does not function according to specification.

These faults or deficiencies do not adversely affect the performance of the SPDS or the accuracy and reliability of the displayed information.

However, the correction of all SPDS faults may result in a small increase in the SPDS response times.

The licensee wi'l continue to correct the system faults and/or accept the system condition and generate a specifi-cation change, if necessary.

The activities are scheduled to be completed prior to start-up followinp the second BVPS-2 refueling outage. The licensee's March 9,1989 letter provides details on these.

We agree with the evaluation contained in this letter.

On the basis that most issues covered by this condition will be resolved /

completed on schedule, and that incompletion of the balance does not constitute a detriment to safe operation of the unit, we find the proposed extension of condition 2.C(8) to accommodate the completion of the HEDs as specified in Table 2 acceptable.

ENVIRONMENTAL CONSIDERATION The amendment changes requirements with respect to the installation or use of facility components located within the restricted area as defined in 10 CFR Part 20.

We have determined that the amendment involve no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. We have previously issued a proposed finding that this amendment involves no significant hazards consideration and there has been no public comment on such finding.

Accordingly, the amendments meet the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9).

Pursuant to 10 CFR 51.22(b) no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendments.

C@CLUSION f

We have concluded, based on the considerations discussed above, thet: (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, and (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendments will not be inimical to the common defense and security or to the health and safety of the public.

Principal Contributors:

Peter S. Tam and Garmon West, Jr.

Attachment:

Tables 1 and 2 l

Dated: April 20, 1989

I 4

TABLE 1 DETAILED C0flTROL ROOM DESIGN REVIEW HED NO.

TITLE APPROVAL / DISAPPROVAL OF DELAYED IMPLEMENTATION 2010-5514 Digital Radiation Monitoring Approved System Printout 2HCR-0202 Communications Console / Merge Approved Switch 2MCR-0203 Walkie-Talkie Communications Approved Systems 2MCR-0001 Control Room Noise / Computer Approved Fan Replacement /HVAC Improvements Study 2MCR-0002 Radiation Monitor ' System /

Approved Cabinet Fan Replacement 2MCR-0008 HVAC System Air Flow Approved 2MCR-0009 Adjustments 2MCR-0019 Emergency Lighting 2ES*-0020 2AB*-0021 L

2V**-2128 Annunciator " Dark Board" Approved

/

' # The NRC staff finds all of the licensee's commitments and justifications in its letter of April 20,1989 (regarding re-evaluating energency lighting levels) acceptable for resolving HEDs 2NCR-0019, 2ES*-0020 and 2AB*-0021.

l

- ___. __- ____m_

.: l TABLE 2 SAFETY-PARAMETER DI SPLAY SYSTEM TITLE APPROVAL /DI SAPPROVAL F0R DELAYED IMPLEMENTATION _

Fire protection system valves associated with Approved containment isolation, 2FPW*A0V204, 205, 206 and 2 FPW*A0V221 l

Main steam isolation / bypass valve position for Approved 2 MSS *A0V101 A, B and C Valves associated with the safety injection-Approved system, 2 SI S*MOV863A and 3, 2SI S*H0V8887A and B,

- 2SI S*MOV8811 A and B Turbine. trip valves, TV-1, 2, 3 and 4 Approved Chemical injection pumps, 2QSS*P24A and B Approved VI STA. display generator 173,176 and 309 Approved System faults 47 and 228 Approved Digital radiation monitoring system inputs, Approved

~ 244 and 379 Deletion of communication processor,138 Approved Display-related faults, 383 Approved Point processing. faults, 223, 225, 297, 343, Approved 359, 377, 382-Documentation-related faults, 287, 362 Approved Logging faults, 331 Approved M k.

-__----a--a-.---- - _ - - - - - - - - -.---- - - _ _

--u--