Forwards Notice of Denial of 880831 Proposed Amend to License NPF-29,changing Operational Condition 5* Re Fuel Transfer Gate.Inadequate Consideration Given to Potential for Inadvertent Draining of Reactor Pressure Vessel
ML20245A888
Person / Time
Site: Grand Gulf 
Issue date: 06/13/1989
From: Adensam E
Office of Nuclear Reactor Regulation
To: Cottle W
SYSTEM ENERGY RESOURCES, INC.
Shared Package
ML20245A890 List:
References
TAC-69257, NUDOCS 8906220242
Download: ML20245A888 (2)


Text

- - -

June 13, 1989 l

1

' Docket No. 50-416-DISTRIBUTION Mr. W. T. Cottle L

Vice President, Nuclear Operations p

_ System Energy Resources, Inc.

I Post Office Box 23054 Jackson, Mississippi 39205 L

Dear Mr. Cottle:

j g

n

SUBJECT:

-DENIAL OF AMENDMENT REQUEST NO. PCOL-88/15 REGARDING FUEL TRANSFER

' GATE - GRAND GULF NUCLEAR STATION UNIT 1-(TAC NO. 69257) j i

By letter dated August 31, 1988,- System Energy Resources, Inc. (SERI) submitted a proposed amendment to the Grand Gulf Nuclear Station, Unit 1, Operating License No.-NPF-29. The proposed amendment would change the Technical Specifica-tions (TS) by changing Operational Condition 5* to allow the fuel transfer gate to be in place during refueling when the. reactor cavity is flooded and l

either the Emergency Core Cooling System (ECCS) (TS 3/4.5.2) or the Suppression Pool (TS 3/4.5.2) is inoperable.

After careful review,.the NRC staff has concluded that your proposal cannot be approved because_ inadequate consideration was given to the potential for

' inadvertent draining of the reactor pressure vessel due to misalignment of the residualheatremoval-(RHR) valves. These events, which have occurred at

, several BWR plants, require automatic isolation of the RHR. system and automatic injection of water by at least one ECCS subsystem to assure the core will remain covered with water. SERI has committed to evaluate whether TS 3/4.5.2 should be changed to take this event into account in its submittals regarding use of an alternate decay heat removal system. Changes to Operat-ional Condition 5* may be considered at the same tine.

A copy of the Notice of Denial of Amendment to facility Operating License and Opportunity for Hearing to be published in the Federal Register is enclosed for your information.

Sincerely, Original Signed By:

Elinor G. Adensam, Director Project Directorate II-1 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

Enclosure:

As stated 0Fo i cc w/ enclosures:

/

See next page i

LA. F I-I SR 0C P I-1 PA:

n LKintner:sw WHohes nsam 6/ /89 6/ /89 6

89 6 g /89 6/ / 389 8906220242 890613 DR ADOCK 0500 6

1 Mr. W. T. Cottle I

System Energy Resources, Inc.

Grand Gulf Nuclear Station (GGNS) cc:

Mr. T. H. Cloninger Mr. C. R. Hutchinson Vice President, Nuclear Engineering GGNS General Manager and Support System Energy Resources, Inc.

System Energy Resources, Inc.

P. O. Box 756 P. O. Box 23054 Port Gibson, Mississippi 39150 Jackson, Mississippi 39205 q

Robert B. McGehee, Esquire The Honorable William J. Guste, Jr.

Wise, Carter, Child, Steen and Attorney General Caraway Department of-Justice P. O. Box 651 State of Louisiana Jackson, Mississippi 39205 Baton Rouge, Louisiana 70804 Nicholas S. Reynolds, Esquire Office of the Governor Bishop, Liberman, Cook, Purcell State of Mississippi and Reynolds Jackson, Mississippi 39201 1400 L Street, N.W' Washington, D.C.

20005-3502 Attorney General Gartin Building Mr. Ralph T. Lally Jackson, Mississippi 39205 Nanager of Quality Assurance Middle South Utilities System Mr. Jack McMillan, Director Services, Inc.

Division of Solid Waste Management 639 Loyola Avenue, 3rd Floor Mississippi Department of Natural New Orleans, Louisiana 70113 Resources P. O. Box 10385 Mr. John G. Cesare Jackson, Mississippi 39209 Director, Nuclear Licensing System Energy Resources, Inc.

Alton B. Cobb, M.D.

P. O. Box 23054 State Health Officer Jackson, Mississippi 39205 State Board of Health P. O. Box 1700 Mr. C. B. Hogg, Project Manager Jackson, Mississippi 39205 Bechtel Power Corporation P. O. Box 2166 President Houston, Texas 77252-2166 Claiborne County Board of Supervisors Mr. H. O. Christensen Senior Resident Inspector Regional Administrator, Region II U.S. Nuclear Regulatory Comission U. S. Nuclear Regulatory Comission Route 2, Box 399 101 Marietta Street l

Port Gibson, Mississippi 39150 Suite 2900 Atlanta, Georgia 30323

. _ _ _. - _ _ _. _..