__

ENCLOSURE 3 PLANT Y0GTLE - UNITS 1, 2.

NRC DOCKETS 50-424, 50-425 OPERATING LICENSES NPF-66, NPF-81 REVISION TO TECHNICAL SPECIFICATION 5.3.1

' INSTRUCTIONS FOR INCORPORATION The proposed amendment to the Technical Specification ( Appendix A to Operating Licenses NPF-68 and NPF-81) would be incorporated as follows:

Remove Page Insert Page 5-4 5-4 E3-1 6p{f6190137e90s12 ADOCK 05000424 j

p.

enc J

. i.,.

DESIGN

.A10RES

5. 3 REACTOR CORE l

FUEL ASSEMBLIES 5.3.1 The core sha11'contain 193 feel assemblies with each fuel assembly containing 264 fuel rods clad with Zircaloy-4.

Each fuel rod shall have a nominal active fuel length of 144 inches.

The initial core loading shall g

have a maximum enrichment not to exceed 3.2 weight percent U-235.

Reload fuel shall be similar in physical desipr o initial core loading and shall have a maximum enrichment not to exc tg w 'ght percent U-235.

/M~7~

CONTROL ROD ASSEMBLIES 5.3.2 The core shall contain 53 full-length control rod assemblies.

The control rod assemblies shall contain a nominal 142 inches of absorber material.

The nominal absorber composition shall be 95.5% natural halfnium and 4.5%

natural zirconium.

All control rods shall be clad with stainless steel.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE,AND TEMPERATURE 5.4.1 The Reactor Coolant System is designed and shall be maintained:

In accordance with the Code requirements specified in Section 5.2 a.

of the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements,

'i b.

For a pressure of 2485 psig, and For a temperature of 650*F, except for the pressurizer which is c.

680 F.

VOLUME 5.4.2 The total water and steam volume of the Reactor Coolant System is 12,240 + 100 cubic feet at a nominal T,yg of 588.5'F.

4 5.5 METEOROLOGICAL TOWER LOCATION 8

5.5.1 The meteorological tower shall be located as shown on Figure 5.1-1 and 5.1-2.

l

)

l i

V0GTLE UNITS - 1 & 2 5-4

~

l

_