ML20238C562
| ML20238C562 | |
| Person / Time | |
|---|---|
| Site: | Waterford |
| Issue date: | 09/03/1987 |
| From: | Gagliardo J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Dewease J LOUISIANA POWER & LIGHT CO. |
| References | |
| NUDOCS 8709100203 | |
| Download: ML20238C562 (3) | |
Text
s
['
14
.1 scp 3 1987-
)j
' 3. s.
\\
u
,InRepiyRdferTo,:
Docketl' 50-382
^
/
1 i
'l Louisiana Power & Light Company-
')
.L ATTN:
J. G. Dewease, Shnior Vice President
[
f'.
Nuclear Operations
\\..317 Baronne Street 1
'I New Orleans,. Louisiang 70160 Gentlemen:
The NRC'is preparing'for Regulatory Effectiveness Reviews-for FY 88. To
' assist in this preparation, you are requested to transmit.one full-size copy
'q of the drawings identified by category in.the enclosure to'Mrs Rocio Gallegos, USNRC, EWS-305A, Washington, D.C., 20555 by October 31, 1987..
Thank you for your help in this matter, and if you have any questions regarding this request, please contact Mr. Larry Yahdell of the Region IV staff at (817) 860-8108'or Mrs. Gallegos at'(301) 492-8852.
Sincerely'.
i ORIGINAL SIGNED BY:
37 J. E. Gagliardo, Chief Reactor Projects Branch
Enclosure:
As stated CC:
Louisiana Power & Light. Company ATTN:
G. E. Wu11er, Onsite Licensing Coordinator P? 0. Box B K111ona, Louisiana 70066 i
Louisiana Power & Light Company ATTN:
N. S. Carns, Plant Manager P. O. Box B Killona, Louisiana 70066 r
f.
k RIV:C:RPSB C
0/A C:RPB0 AI 87-286 LAYandell J J bdon JEGagl' a do.
O ll /87 g
87
%/ ly7 g
qi, 8709100203 870903
$M ' ADocM osooossa k.
e
!)y en
Louisiana Power & Lignt Company cc's(cont'd):
Middle South Services ATTN:
Mr. R. T. Lally P. O. Box 61000 New Orleans, Louisiana 70161 Louisiana Power & Light Company ATTN:
K. W. Cook, Nuclear Safety and Regulatory Affairs Manager 317 Baronne Street P. O. Box 60340 New Orleans, Louisiana 70160 Louisiana Radiation Control Prograni Director bec to DMB (IE-04) bec distrib. by RIV:
RPB D. Weiss, RM/ALF Resident Inspector R. D. Martin, RA Section Chief (RPB/A)
DRSP RPSB RSB MIS SYSTEM RST' Operator l
a RIV File j
Inspector Sect.bn Chief L. A. Yandell R. L. Bangart i
R. E. Hall A. B. Earnest R. C. Gallego:, NRR/RSGB Project Insps or, RPB J. Wilson, NR Project Inspector
j s.
n,
~
r*,,...
,7 ""
y
.-4 e
]
t.z t
REQUESTEDDRAWINGSNEEDEDTOSUPP0kh
., /
REGULATORY EFFECTIVENESS REVIEWS f
I
/
General arrangement drawings of the site and buildings housing safety related material One line electrical drawings showing on-site emergency AC and DC power Motor Control Center Loadings I
P&ID for Service Water System Emergency Core Cooling System (e.g., HPSI, LPSI, Containment Spray, Fan Coolers)
{
i Auxiliary or Emergency Feedwater System Component Cooling Water System Drawings showing Charging System and Decay Heat Removal (if not included above) 1 ENCLOSURE L___--_______--__________________.
_