SO -3 YG November 27',1987) l.
l MEMORANDUM T0: Charles G. Norelius, Director DISTRIBUTION Division of Reactor Projects, Doctet4He/ PD31 Plant Region III
.NRC & Local PDRs GHolahan RIngram l
'FROM:
Dennis M. Crutchfield, Director-ADeAgazio EJordan Division of Reactor Projects - III, 0GC JPartlow IV, V & Special Projects ACRS'(10)
Office of Nuclear Reactor Regulation-
SUBJECT:
REVIEW OF TOLEDO EDISON COMPANY ASSESSMENT OF INPUT ERRORS DISCOVERED IN SMALL BREAK LOSS-OF-COOLANT ACCIDENT ANALYSIS TIA86-29FM(TAC 62086)
Your memorandum to G. Holahan dated July 18, 1986, requested NRR assistance to review the effects of certain non-conservative assumptions erroneously.
used by Toledo Edison in'its analyses for Small Break Loss-of-Coolant accidents.
1 The non-conservative assumptions ~related to the low pressure trip setpoint,.
steam generator water level, main feedwater flow coastdown, and using both steam generators for decay heat removal.
]
The NRR staff has reviewed analyses presented by Toledo Edison and other documentation available. Based on this review, the staff agrees that certain of the values used in the SBLOCA analyses are' incorrect'resulting in incomplete compliance with 10 CFR 50, Appendix K but concludes that there is reasonable assurance that the Davis-Besse ECCS satisfies 10 CFR 50.46' performance i
requirements and, therefore, operation of the plant poses.no undue risk to public health and safety. The Safety Evaluation supporting this conclusion is enclosed.
This completes our efforts on TIA 86-29 FM.
original sianed bv GMH for/
Dennis M. Crutchfield, Director I
Division of Reactor Projects -'111 IV, V & Special Projects Office of Nuclear Reactor Regulation j
CONTACT: Albert De Agazio, NRR 49-28186 PM:PD31g/k D/PD3 :
S bMVirg//87 ADeAgazio ilio GHolahan DCrutchfield
// /
87
/ //,2e
// p)/87 h/f)/87 i
Q2Oggg gy 6
P
-.