ML20214T75011 September 1986BABCOCK & WILCOX CO.
Dunn B
Pawug J
DB Small-Break LOCA Analysis Assumptions EvaluationOther
ML20214T72325 November 1986FirstEnergy
Williams J
Informs of Major Discrepancies Between B&W Topical Rept BAW-10075A,Rev 1, Multinode Analysis of Small Breaks for B&W 177-Fuel Assembly...Plants W/Raised Loop Arrangements & Internal Vent Valves, & as-built Configuration of PlantOther
ML20236U65327 November 1987NRCSafety Evaluation Re Effects of Errors in Util Analysis of Small Break Loca.Use of Incorrect Values in Analysis Results in Incomplete Compliance w/10CFR50,App K.Plant Poses No Risk to Public Health Due to Meeting 10CFR50.46 RequirementsApproval
ML20236U64727 November 1987Crutchfield D
Office of Nuclear Reactor Regulation
Forwards Safety Evaluation Re Assessment of Errors in Util Analysis for Small Break Loca,Per 860718 Request.Incorrect Values Used in Analysis Result in Incomplete Compliance W/ 10CFR50,App K.Performance Requirements of 10CFR50.46 MetApproval