June 26, 1998 Mr. Rot:ert A. Willi:ms Safegu rds Coordin: tor Westinghouse Electric Corporation
{
7-Commercial Nuclear Fuel Division Drawer R Columbia, South Carolina 29250
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION REGARDING CRITICALITY SAFETY EVALUATIONS (TAC NOS. L30812 AND L30877)
Dear Mr. Williams:
This refers to your submittals dated October 4,1995 and April 30,1996, which are being used to partly satisfy the requirements of Safety Condition S-2 of Materials License SNM-1107.
These two submittals reflect the high risk situations, as agreed upon by both Westinghouse and NRC staff, of the Ammonium Diuranate Conversion (ADU) Process and the Uranyl Nitrate (UN)
Bulk Storage System.
Based on discussions during the January 9,1998, meeting, NRC staff visited your site several times from January 1998 to April 1998. Although you provided a summary of the Criticality
{
Safety Evaluation (CSE) and fault tree information for the UN Bulk Storage System in the submittal dated April 30,1998, (TAC No. L31079), that submittal does not provide the complete information needed to satisfy the requirements of Safety Condition S-2 for the UN Bulk Storage System. Based on the results of those site visits and our review of your submittals, additional information is needed before final action can be taken on your request.
The NRC requests that you submit Section 1 (Process Description) and Section 5 (Safety Analysis) of the CSEs for both the ADU Process and UN Bulk Storage System for NRC staff review. The additionalinformation should be provided within 30 days of the date of this letter.
Note that non-proprietary versions of these sections are required per 10 CFR 2.790 unless the entire sections are proprietary or after blacking out the proprietary parts of the sections, the remaining portions of the sections become meaningless. Please reference the above TAC Nos.
in future correspondence related to this request.
If you have questions regarding this matter, please contact me at (301) 415-8116.
Sincerely.
Original si Charles E. Gaskned by: HFelsher for
\\
O-in Licensing Section 1 i
,,2 Licensing Branch f( O Division of Fuel Cycle Safety and Safeguards, NMSS Docket 70-1151 License SNM-1107 bm <dk O.."l < m l
cc:
Mr. Wilbur Goodwir', Regulatory Affairs Westinghouse Electric Company Distribution: (Control Nos. 490S and 580S)[ PARTIAL]
Docket 70-1151 PUBLIC NRC File Center Region Il FCOB FCLB R/F FCSS R/F NMSS R/F DAyres. Ril SChotoo
[giwrai15 wpd)
- see previous concurrence OFC FCLB FCLB FCLB FCLB b
FCLB C
NAME HFelsher
- MAGalloway
- CGaskin
- PShea @
MAdatNO 06/h8 06fM/98 06/p/98 06Qh 06M/98 DATE 9807160196 980626 PDR ADOCK 07001151 C
e p Rt k
UNITED STATES Oj j
NUCLEAR REGULATORY COMMISSION t
WASHINGTON, D.C. 306t60001 Q.
c
%,,,, +,(
June 26, 1998 Mr. Robert A. Williams Safeguards Coordinator.
' Westinghouse Electric Corporation Commercial Nuclear Fuel Division Drawer R Columbia, South Carolina 29250
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION REGARDING CRITICALITY SAFETY EVALUATIONS (TAC NOS. L30812 AND L30877)
Dear Mr. Williams:
This refers to-your submittals dated October 4,1995 and April 30,1996, which are being used to partly satisfy the requirements of Safety Condition S-2 of Materials License SNM-1107.
These two submittals reflect the high risk situations, as agreed upon by both Westinghouse and NRC staff, of the Ammonium Diuranate Conversion (ADU) Process and the Uranyl Nitrate (UN)
Bulk Storage System.
Based on discussions during the January 9,1998, meeting, NRC staff visited your site several times from January 1998 to April 1998. Although you provided a summary of the Criticality Safety Evaluation (CSE) and fault tree information for the UN Bulk Storage System in the submittal dated April 30,1998, (TAC No. L31079), that submittal does not provide the complete information needed to satisfy the requirements of Safety Condition S-2 for the UN Bulk Storage System. Based on the results of those site visits and our review of your submittals, additional information is needed before final action can be taken on your request.
The NRC requests that you submit Section 1 (Process Description) and Section 5 (Safety Analysis) of the CSEs for both the ADU Process and UN Bulk Storage System for NRC staff review. The additionalinformation should be provided within 30 days of the date of this letter.
Note that non-proprietary versions of these sections are required per 10 CFR 2.790 unless the entire sections are proprietary or after blacking out the proprietary parts of the sections, the remaining portions of the sections become meaningless. Please reference the above TAC Nos.
in future correspondence related to this request.
If you have questions regarding this matter, please contact me at (301) 415-8116.
Sincerely, j pl6*
q)n $ N" [#
Charles. Gaskin Licensing Section 1 Licensing Branch Division of Fuel Cycle Safety and Safeguards, NMSS Docket 70-1151 License SNM-1107 i