Forwards SER Re 870814 & 21 Responses to NRC Re Adequacy of One Nuclear Svc Water Pump Sys to Supply Both Units.Design & Operation Meet GDC 5 & GDC 44.Tech Specs Re Nuclear Svc Water Sys Inadequate.Tech Spec Rev Requested
ML20236D434
Person / Time
Site: Catawba  
Issue date: 09/30/1987
From: Varga S
Office of Nuclear Reactor Regulation
To: Tucker H
DUKE POWER CO.
Shared Package
ML20236D436 List:
References
NUDOCS 8710280207
Download: ML20236D434 (2)


Text

_ _ _ _ _ _

4 Docket Nos.: 50-413 30 SEP 1987 and 50-414-Mr. H. B. Tucker, Vice President Nuclear Production Department Duke Power Company 422 South Church Street Charlotte, North Carolina 28242

Dear Mr. Tucker:

Subject:

Adequacy of the Nuclear Service Water System Design - Catawba Nuclear Station, Units 1 and 2 By letters dated August 14 and 21, 1987, you responded to the NRC staff letter dated August 7, 1987, requesting that you provide, pursuant to 10 CFR 50.54(f),

(1) an analysis justifying the adequacy of one nuclear service water pump to supply both units, or (2) a description of actions implemented or planned to be imple-mented that justify continued plant operation in view of staff concerns regarding whether the system satisfies General Design Criteria (GDC) 5 and 44.

As a result of the staff review of your submittals and the infonnation prcvided at the August 27, 1987, meeting, we conclude based on the enclosed Safety Evalu-ation Report that, with the procedures implemented, your design and operation meet GDC 5 and 44 However, the Technical Specifications addressing the nuclear service water sys2.:..:. are inadequate in that they do not reflect the i

shared aspects of the system. Thus, we request that you propose revised Tech-I nical Specifications and associated bases to specifically address the fact that

)

the nuclear service water system action statement applies to both units any time 1

a diesel generator or a shared component is taken out of service, and is appli-cable during all modes of operation.

Should you have any questions regarding this matter, please contact the project manager, Kahtan N. Jabbour at (3011 492-7367.

Sincerely,

\\9

\\

Steven A. Varga, Director Division of Reactor Projects I/II

Enclosure:

As stated cc: See next page i

D.T STR T RQUON:

l (DocketFile3 NRC PDR l

PUII-3 Reading Local PDR MDuncan PRC System SVarga/Glainas ACRS(10) 8710280207 870930 l

PDR ADOCK 05000413 JPartlow KJabbour P

PDR JSmith EButcher EJorda n

[

PDII-Jif$)PI/II g/h /

PDII-3/DRPI/II BC [3 DEA AD I/II

/II KJabbour/ rad MDuncan EB t er GL Das Var a 09/2 (/87 09/Lf/87 09/v/87 09/ 187 0

7 w_-_ _

Mr. H. B. Tucker Duke Power Company

~ Catawba Nuclear. Station Cc:

A.V. Carr, Esq.

North Carolina Electric. Membership Duke ' Power Company Corp.

422 South Church Street 3400 Sumner Boulevard Charlotte, North Carolina 28242 P.O. Box 27306 Raleigh, North Carolina 27611 J. Michael McGarry, III, Esq.

' Bishop. Libennan, Cook, Purcell Saluda River Electric Cooperative, and Reynolds Inc.

1200 Seventeenth Street, N.W.

P.O. Box 929 Washington, Dr C.

20036 Laurens, South Carolina' 29360 North Carolina MPA-1 Senior Resident Inspector Suite 600 Route 2, Box 179N 3100 Smoketree Ct.

York, South Carolina 29745 P.O. Box 29513 Raleigh, North Carolina 27626-0513 Regional Administrator, Region II U.S. Nuclear Regulatory Commission, L.L. Williams 101 Marietta Street, NW, Suite 2900

. Area Manager, Mid-South Area Atlanta, Georgia 30323 ESSD Projects' Westinghouse Electric Corp.

.MNC West Tower - Bay 239 P.O. Box 355 Pittsburgh, Pennsylvania 15230 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health q

South Carolina Department of Health and Environmental Control 2600 Bull Street i

Columbia. South Carolina 29201 County Manager of York County

. York County Courthouse Karen E. Long

)

York South Carolina 29745 Assistant Attorney General N.C. Department of Justice Richard P. Wilson, Esq, P.O. Box 629 Assistant Attorney General Raleigh, North Carolina 27602 S.C. Attorney General's Office P.O. Box 11549 Spence Perry, Esquire Columbia, South Carolina 29211 General Counsel Federal Emergency Management Agency Piedmont Municipal Power Agency Room 840 100 Memorial Drive 500 C Street Greer, South Carolina 29651 Washington, D. C.

20472 Mr. Michael Hirsch Federal Emergency Management Agency Office of the General Counsel 1

Room 840 500 C Street S.W.

Washington, D. C.

20472 l

Brian P. Cassidy, Regional Counsel Federal Emergency Management Agency, Region I

' J. W. McConnach P0CH l

' Boston, Massachusetts 02109 w