b

(

UNITED STATES ATOMIC ENERGY COMMISSION 3,

WASHINGTON. D.C. 20545

%n e#

DEC 10

)

E P. F. Collins, Chief, Operator Licensing Branch, L FT. ST. VRAIN-FUEL HANDLERS On December 6,1974, Mr. W. Hillyard and Mr. f. F. Mathie of Public Service of Colorado met with Mr. J. Holman and Mr. J. Buzy of OLB to review the responsibilities and outline the scope of examination for Fuel Handling Senior Operators at Ft. St. Vrain. OLB had requested this meeting in a letter to Mr. F. Swart on November 22, 1974 The Fuel Handling Foreman, as a licensed operator, is presently limited to performing or directing those tasks outlined in the letter from Mr. F. Swart to Mr. A. Giambusso on July 2,1973 OLB has re-quested that the specific procedures and systems be identified as the responsibility of the Fuel Handling Foreman.

Mr. Hillyard and Mr. Mathie reviewed those systems with us that would be the direct responsibility and additional systems of which he should i

be knowledgeable.

System Operating Procedures Number Title Remarks i

11 Prestressed Concrete Reactor Yessel K

12-03 Reactivity Control-Control Rods K

1 2-04 Orificing System K

12-05 Reserve Shutdown K

13 Fuel Handling Procedure 13-01 New Fuel Receiving and Inspection R

13-02 New Element Inspection R

13 03 New Fuel to Fuel Storage Wells R

13-04 Refueling Procedure R

13-05 Spent Fuel Shipping R

13-06 Fuel Safeguards and Accountability K

13-07 Fuel Handling Purge System R

9 S?

XA o

i l

i M

- DEC 10 P. F. Collins SystemOperatingProcedures(continued)

Number Title Remarks 14-01 Fuel Storage Facility K

14-02 Fuel Storage Facility Auxiliary System K

16-01 Auxiliary Transfer Cask & Storage Wells R

16-02 Hot Service facility-16-03 Viewing Device and Auxiliary Tools K

24 Helium Storage System K

45 Fire Protection System K

46 Reactor Plant Cooling Water System K

61 Decontamination System K

62 Radiation Protection K

I 63 Radioactive Gas K

73 Reactor Building Ventilation K

93-01 Control and Instrumentation K

93-04 Area Radiation Alarms K

j l

K-Knowledgeable

{

R-Responsible I

  • -Not resolved We outlined _.the scope of the written and operating examinations which have been given to Fuel Handling Operators at water reactors and made modifications in those areas which were not applicable and included those which are unique to Ft. St. Vrain.

We will need additional infomation to develop the written and operating This material includes system description or abstracts, alarm and ab-test.

normal procedures.

J. Holman will visit the site on December 20,1974, to obtain this infomation and will take this assignment. We estimate a total of three man weeks to complete this assignment.

Attached is the training which fuel handlers have received.

J.J.Buzy P&RR Group Leader

Enclosure:

Fuel Handler Lectures, To Date 1

1 i

FUEL HANDLER LECTURES, TO DATE Reactor Site Reactor Fuel, Reflector, Generel Arrangement Primary Coolant Flow, General

.j Control Rod Drives, Orificing, Reserve Shutdown Inst. & Service Air Circulating Water Service Water Reactor Plant CWS Emergency D.G. Inst. Bus. AC, DC Fire Protection PCRV and Aniliary Piping Rad Liquid Waste Rad Gas Waste Solid Waste Disposal Helium Storage System l

Reactor Plant HVAC i

Personnel Monitoring Turbine EHC System fuel hand'ing Equip. Spent Fuel Shippin Nuclear Instrumentation (Start Up Only)g Hot Service Facility, In-Core Tools Decontamination System Engineered Safeguards Fundamental Reactor T.,ysics Atomic & Nuclear Physics Review