Approves Util 870817 Request to Use Instrumented Insp Technique (IIT) Developed by Hata Intl,Inc at Unit 2.Use of IIT Previously Approved for Unit 1 in D Mcdonald & for Generic Use in C Thomas
ML20235V949
Person / Time
Site: Beaver Valley
Issue date: 10/02/1987
From: Stolz J
Office of Nuclear Reactor Regulation
To: Sieber J
DUQUESNE LIGHT CO.
References
TAC-61349, NUDOCS 8710150422
Download: ML20235V949 (2)


Text

_ _ _ _ _ _ _ _ _ _ - _. --

OCT 0 21987 Docket No. 50-41?

Mr. J. D. Sieber, Vice President Duquesne Light Company Nuclear Operations Post Office Box 4 Shippingport, PA 15077 Dear Mr. Sieber

SUBJECT:

BEAVER VALLEY UNIT 2 - Instrumented Inspection Technique (IIT) i (TAC 61349)

By letter dater August 27, 1987 you identified to us the plant system on which you planned to apply the IIT developed by HATA International, Inc. We have approved your application of IIT to certain systems of Beaver Valley Unit 1 (Letter, D. Mcdonald to J. J. Carey, May 15,1986).

In addition, we have approved generic use of IIT (Letter, C. Thomas to Askwith of HAFA, November 7, 1985).

Therefore, your request to use the IIT on Beaver Valley Unit ? on systems identified in your letter of August ?7,1987 is approved.

If you have any questions, please feel free to contact your Project Manager, Mr. P. Tam. This review was performed by Mr. G. Johnson.

Sincerely,

/si John F. Stolz, Director Project Directorate I-4 Division of Reactor Projects I/II cc See next page DISTRIBUTION Docket File-* NRC & Local PDRS S. Varga B. Boger S. Norris P. Tam OGC-Bethesda E. Jordan J. Partlow ACRS (10)

(PDI-4 Files)

G. Johnson I

kk k2 K

O PTam:In[2Y, JSt@ds LAP I-4 PDI-4 EMTR PD-S rs GJohnsbf1 s

Cf BC/87

/0 / [ /87

/0/ / /87

/0 /g/87 t

s.

OCT ? 21987 i

Mr. J. J.,Carey Duquesne Light Company.

Beaver ^ valley 2 Power Station ec:

1 Gerald Charnoff, Esq.

Mr. Kenneth Grada, Manager

' Jay E. Silberg, Esq.

Safety and Licensing, Shaw, Pittman, Potts & Trowbridge Duquesne Light Company 2300 N Street, N.W.

P. O. Box 4 Washington, DC.20037 Shippingport, Pennsylvania 15077

. Mr., C, 'd. Ewing, Quality Assurance Pennsylvania Office of Consumer Manager Advocate j

Quality Assurance Department ATTNi Michael Bardee Duquesne f.ight Company 1425 Strawberry Square P. O. Bsx 186 Harrisburg, Pennsylvania 17120 l

Shippir;gport, Pennsylvania 15077

]

John D. Burrows, P.E.

1 Director, Pennsylvania Emergency Director of Utilities l

Management Agency State of Ohio l

Room B-151 Public Utilities Comission l

Transportation & Safety Building 180 East Broad Street

. Harrisburg, Pennsylvania 17120 Columbus, Ohio 43266-0573 Mr. T. J. Lex Bureau of Radiation Protection Westinghouse Electric Corporation PA Department of Environmental 1

Power Systems Resources

(

P. O. Box 355 ATTN:

R. Janati Pittsburgh, Pennsylvania 15230 P.O. Box 2063 Harrisburg, Pennsylvania 17120 Mr. P. RaySircar i

Stone & Webster Engineering Corporation BVPS-2 Records Management Supervisor P. O. Box 23?5 Duquesne Light Company Boston, Massachusetts 02107 Post Office Box 4 Shippingport, Pennsylvania 15077 U. S. NRC John A. Lee, Esq.

P. O. 181 Duquesne Light Company Shippingport, Pennsylvania 15077 1 0xford Centre i

301 Grant Street Regional Administrator, Region I Pittsburgh, Pennsylvania 15279 U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 1

1 1