Advises That Relief Request VR-51 Treated as Cold Shutdown Justification Request.No Further Action Required.Addl Info Required Re Relief Requests VR-20-R1,PR-0-R1 & PR-10-R1,per 870730 Telcon
ML20235K651
Person / Time
Site: Fermi 
Issue date: 09/28/1987
From: Stefano J
Office of Nuclear Reactor Regulation
To: Sylvia B
DETROIT EDISON CO.
References
TAC-63529, NUDOCS 8710050182
Download: ML20235K651 (3)


Text

_

't-p tro

[

o UNITED STATES NUCLEAR REGULATORY COMMISSION

]

o

E WASHINGTON, D. C. 20555 4

September 28, 1987 Docket No. 50-341

]

'Mr. B. Ralph Sylvia 1

Group'Vice President - Nuclear Operation Detroit Edison Company 6400-North Dixie Highway Newport, Michigan 48166

)

Dear Mr. Sylvia:

J

SUBJECT:

PARTIAL RESPONSE TO FERMI-2 INSERVICE TESTING PROGRAM FOR PUMPS AND VALVES RELIEF REQUESTS (TAC N0. 63529) l The staff has reviewed the pump and valve testing relief requested to the Fermi-2 Inservice Testing (IST) Program, submitted by Detroit Edison letters dated April 24, 1986, July 22, 1986, August 22, 1986, and February 21, 1987.

With the exception of the Main Steam Isolation Valve - Leakage Control System (MSIV-LCS) isolation valves testing, the staff has identified the need for additional information relative to the relief requested to complete its review of Relief Request Nos. VR-20-R1, PR-0-R1 and PR-10-R1, The additional information needed was discussed with your staff in a telecon on July 30, 1987.

Relief Request No. VR-51 proposes to full stroke, exercise, and time the MSIV-LCS isolation valves during plant cold shutdown instead of during plant operation as is currently stated in the IST Program.

The basis for this change is that the MSIV-LCS isolation valves cannot be exercised during plant operation because those isolation valves are not designed to operate at pressures greater than 50 psig; and the exercise of the MSIV-LCS isolation valves at rated pressure would introduce potential over pressurization.

The staff considers this basis sufficient to justify the proposed alternate testing of the MSIV-LCS isolation l-valves during cold shutdown.

It should be noted, that Section XI of the ASME Code, Paragraph IWV-3412, permits Category A and B valves to be tested during plant cold shutdown if the licensee provides justification that the valve design will not permit testing during plant operation.

A such, Relief Request No. VR-51 should have been 8710050182 870928 PDR ADOCK 05000341 P

PDR l

l Mr. Sylvia September 28, 1987

)

l C

r proposed as a " cold shutdown justification."

In accepting Relief Request No.

VR-51, the staff treated your proposed alternate testing during cold shutdown as a " cold shutdown justification" request.

Therefore, no further action is required on your part concerning that request.

However, should'a similar relief request be foua necessary for implementing the subject IST Program in the future, a " cold shutdown justification" submittal should be provided for staff review and acceptance.

l Original signed by John J. Stefano, Project Manager Project Directorate III-1 Division of Reactor Projects - III, IV V

& Special Projects cc:

See next page bec:

L. Marsh Y. Li E. Greenman, RIII DISTRIBUTION

Docket-File NRC &~Leoal PDRs PD31 Plant Gray GHolahan RIngram JStefano OGC-Beth EJordan JPartlow ACRS(10)

/

' PM : 31:DRSP D/PD31:DRSP Ste ano:lt MVirgilio /^~

9/p 87 9/A /87

= _ _ _ - _ _ _ _ _ _ _ - _ _ _ _ _ - - _

,R Pjr? B.' Ralph Sylvia

. Detroit Edison Company' Fermi-2 Facility CC:

l Mr. Harry H. Voigt, Esq.

Ronald C. Callen LeBoeuf, Lamb, Leiby & MacRae Adv. Planning Review Section..

1333 New' Hampshire Avenue, N.W.

Michigan Public Service Commission Washington, D.C. 20036 6545 Mercantile Way P. O. Box 30221 John Flynn, Esq.

. Lansing, Michigan 48909 Senior Attorney Detroit Edison Company Regional Administrator, Region III 2000 Second Avenue U.S. Nuclear Regulatory Commission Detroit, Michigan 48226 799 Roosevelt Road Glen Ellyn, Illinois 60137

' Nuclear Facilities and Environmental Monitoring Gection Office

' Di vi sior, of Radiological Health P. O. Box 30035 Lansing,. Michigan 48909 Mr. Steve Frost Supervisor-Licensing Detroit Edison Company Fermi Unit ~2 6400 North Dixie Highway Newport, Michigan 48166 Mr. Thomas Randazzo Director,. Regulatory Affairs Detroit Edison Company Fermi Unit 2' 6400 North Dixie Highway Newport, Michigan. 48166 Mr Walt Rogers U.S. Nuclear Regulatory Commission Resident Inspector's Office 1

6450 W. Dixie Highway Newport, Michigan. 48166 Monroe County Office of Civil a.

Preparedness 963 South Raisinville Monroe, Michigan 48161

_ - _ _ _ _. _ _ _ _ _ _ _ _ _ _.