NUDOCS 8709290491
Download: ML20235G210 (1)


Text

,

SEP 2 41987.

Docket Nos.-50-325/324 DISTRIBUTION

?LDocket a ACRS(10) d NRC & Local PDRs PD 21'r/f-Mr. E. E. Utley Senior Executive Vice President S. Varga Power Supply and Engineering.& Construction G. Lainas

.l Carolina Power & Light Company E. Adensam-R P. O. Box 1551 E. Sylvester.

Raleigh, North Carolina 27602 P. Anderson-l OGC-B

Dear Mr. Utley:

E. Jordan J. Partlow

SUBJECT:

BRUNSWICK LICENSING ACTIONS PRIORITY LIST By letter dated September 22, 1987, you provided a prioritized list of licensing actions under review by the NRC for Brunswick Steam Electric Plant, Units 1 and.

2.

For Item No.14, Mechanical Vacuum Pump. Testing (Proposed Amendment 85TSB18),

you requested that NRC issue the proposed Technical Specification (TS) change by August 7, 1987.

In a telephone conversation' on July 16, 1987, we informed members of your staff that issuance of this amendment was being held in a'oeyance until receipt of updated TS pages from CP&L. As we have not yet received these updated pages it would have been appropriate.for the licensing action priority list to. indicate that resolution'of this item is " awaiting additional information from CP&L." We, therefore, request that the updated TS pages be provided with a new requested date of issuance, or that the priority list be changed to show that this item is awaiting information from CP&L.

I The reporting and/or record keeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-512.

Sincerely,

/s/

Ernest D. Sylvester, Project Manager Project Directorate 11-1 Division of Reactor Projects I/II 1

l cc: See attached list 8709290491 070924 PDR ADOCK 05000324 P

PDR k

LA:J R

PM:PD21:DRPR

DRPR PAnil on ESylvester/dsf EAdpsam 9/

87 9/M/87

.9/

/87.

,