Docket No. 50-219 Mr. P. B. Fiedler Vice President and Director I

Oyster Creek Nuclear Generating Station P. O. Box 388 Forked River, New Jersey 08731

Dear Mr. Fiedler:

SUBJECT:

MISCELLANE0US AMENDMENTS / SEARCH REQUIREMENTS OYSTER CREEK NUCLEAR GENERATING STATION (TAC #65199)

This is to acknowledge receipt of the GPU Nuclear Corporation letter, dated l

December 2, 1986, which transmitted a proposed amendment to the Oyster Creek Nuclear Generating Station Physical Security Plan, in response to the Miscellaneous Amendments and Search Requirements.

The submitted document has been reviewed and we have determined that additional information and revisions to the plan are required prior to our approval.

The enclosed comments are based upon pertinent NRC regulations and published guidance describing methods, acceptable to the NRC staff, for implementing specific parts of those regulations.

It is requested that you provide your response to these comments within 30 days from receipt of this letter.

The reporting and/or record keeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.

Should you have any questions concerning the enclosed comments, please contact the reviewer, Barry Manili, at (301) 492-7077.

Sincerely, Alexander W. Dromerick, Project Manager Project Directorate I-4 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

Enclosure:

DISTRIBUTION W/ ENCLOSURES:

Physical Security Plan Comments RSGB rf Sec rf BManili Buracker (2) cc w/ enclosure:

Region I SNorris See next page ADromerick Docket File 50-219 Case File NRC PDR B709230M9 Q N i9 RErickson wo/ enc 1 Local PDR PDR ADOCK PDR LBush wo/ enc 1 Y

/%l OFC :RSGB

RSGB
RSG
PD I-4
PD I-4

.......: l.t.:&- :.RSGB

' sy,..

NAME$BMMi'.i$CBurak Bush (

$RE

$S M on erick $

....-.--...-____....____.-__.....-.......__.7_-.._-..-_____-...-.-___________....-_----

DATE :8/M/87

8/M/87
8/ /87
8/9W87
C /g /87
[ //-/87

/

Mr. P. B. Fiedler Oyster Creek Nuclear Oyster Creek Nuclear Generating Station Generating Station ec:

Ernest L. Blake, Jr.

Resident Inspector Shaw, Pittman, Potts and Trowbridge c/o U.S. NRC 2300 N Street, NW Post Office Box 445 Washington, D.C.

20037 Forked River, New Jersey 08731 J.B. Liberman, Esquire Commissioner Bishop, Liberman, Cook, et al.

New Jersey Department of Energy 1155 Avenue of the Americas 101 Commerce Street New York, New York 10036 Newark, New Jersey 07102 Mr. David M. Scott, Acting Chief Regional Administrator, Region I Bureau of Nuclear Engineering U.S. Nuclear Regulatory Commission Department of Environmental Protection 631 Park Avenue CN 411 King of Prussia, Pennsylvania 19406 Trenton, New Jersey 08625 BWR Licensing Manager GPU Nuclear Corporation i Upper Pond Road Parsippany, New Jersey 07054 Deputy Attorney General State of New Jersey Department of Law and Public Safety 36 West State Street - CN 112 Trenton, New Jersey 08625 Mayor Lacey Township 818 West Lacey Road Forked River, New Jersey 08731 Licensing Manager Oyster Creek Nuclear Generating Station Mail Stop: Site Emergency Bldg.

P. O. Box 388 Forked River, New Jersey 08731

b Docket No. 50-219 COMMENTS ON PHYSICAL SECURITY PLAN CHANGES (MISCELLANEOUS AMENDMENTS 1.dD SEARCH REQUIREMENTS)

OYSTER CREEK NUCLEAR POWER PLANT Clarify in Section 8.2.5 (item #6) that dropping safeguards measures 1

suspended during an emergency do not apply to vital area access controls for life threatening situations not. involving public health and safety.

Reference 10 CFR 50.54(x) and (y) and Generic Letter 87-08 (Q&A #3).

Provide a commitment that if security force members leave the protected area to perform official duties subsequent to their initial entry and search, they will be. searched prior to re-entry into the protected area

{

if they have not been under direct observation or accompanied by another i

member of the security force.

Reference 10 CFR 73.55(d)(1) and Generic i

Letter 87-08-(Q&A #11).

Provide a commitment that an access authorization system will be' established to limit unescorted access to vital areas during nonemergency conditions to those individuals required to perform specific duties.

Reference 10 3

CFR 73.55(d)(7)(1).

Provide a commitment that a current authorization access list will be established for each vital area.

Reference 10 CFR 73.55 (d)(7)(1)(A).

4 Provide a commitment that vital area access lists shall be updated and reapproved by the cognizant manager / supervisor at least every 31 days.

Reference 10 CFR 73.55(d)(7)(1)(A).

j Provide a commitment that identification badge and other entry devices shall be retrieved prior to or simultaneously upon notification of termination.

Reference 10 CFR 73.55(d)(7)(1)(C).

Revise the commitment on page 54 when addressing prompt access to vital equipment to accommodate the potential need for rapid ingress or egress of individuals during emergency conditions or situations.

Indicate how this prompt access will be ensured (e.g., by issuing override keys to appropriate operators and security force members at the start of each shift, or by other acceptable means).

Reference 10 CFR 73.55(d)(7)(ii) and Generic Letter 87-08 (Q&A #6).

Provide a commitment to periodically (annually) review physical security and contingency plans and procedures to evaluate their potential impact on plant and personnel safety.

Delete the reference to i 3 months on page 62.

Reference 10 CFR 73.55(d)(7)(ii)(B) and Regulatory Guide 5.65.

Provide a commitment that whenever an individual's unescorted access is revoked due to lack of trustworthiness, reliability, or inadequate work performance, keys, locks, combinations, and related access control devices to which that person had access shall be changed or rotated.

Reference 10 CFR 73.55(d)(9).

j J

Docket No. 50-219 -

Provide a commitment that the CAS will be designated as a vital area in accordance with 10 CFR 73.55(e)(1) as amended.

Reference 52.FR 12364.

Indicate what components of the secondary power supply system will be protected as vital.

Refsrence 10 CFR 73.55(e)(1) and Generic Letter 87-08 (Q&A #18).

Provide a commitment to maintain a log indicating name, badge number, time of entry, and time of exit of all individuals granted accass to a vital area except those individuals entering or exiting the reactor control room.

Reference 10 CFR 73.70(d).

._.