ML20217C415
| ML20217C415 | |
| Person / Time | |
|---|---|
| Site: | Byron, Braidwood |
| Issue date: | 07/08/1991 |
| From: | Checca A COMMONWEALTH EDISON CO. |
| To: | Murley T Office of Nuclear Reactor Regulation |
| References | |
| GL-88-17, TAC-69725, TAC-69726, TAC-69727, NUDOCS 9107150258 | |
| Download: ML20217C415 (1) | |
Text
__.
[
N Ccmm:nweahh Edison k
/
/ 1400 Opus Place
(
(C Downers Grove. Illinois 00515 i
'v July 8,1991 Dr. Thomas E. Murley, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555
Subject:
Byron Station 8.Inits 1 and 2 Braidwood Station Units 1 and 2 Generic Letter 88-17 Supplemental Information Loss of Decay Heat Removal TAC Nts. 69/25,69726,69727 NBC_DockeLNos _50-454/455fanrL50-456L457__
Reference:
a) January 22,1990 letter from T.K. Schuster to T.E. Murloi b) April 23,1991 letter from A.R. Chocca to T.E. Murley
Dear Dr. Murley:
Commonwealth Edison provided status on the implementation of Generic Letter 88-17, l.oss of Decay Heat Removal, for Byron and Braidwood Stations in reference (b). As indicated in reference (a) Byron station has comaleted this modification. This letter provides an update on the status of the Residual F eat Removal (RHR) system iconic display at Braldwood Station.
Byron Station staff has designed a computer graphic for the Main Control Room. The graphic displays data in real time and reflects the status of the refueling water level and RHR pump parameters. The display is a mimic of the reactor vessel, steam generator, pressurizer and RCP, and is to scale with respect to plant elevation.
Tha screen displays bar graphs and literal values for the four refueling level instruments and a pressunzer levelinstrument. Also shown are the RHR pump suction and discharge pressures, discharge temperature and motor bearing temperatures.
This display software installation has been completed at Braidwood Station. The modification was tested and placed into service (for both unit 1 and 2) on May 15, 1991. This was approximately six weeks ahead of the schedule proposed in reference (b). Please direct any further questions regarding this matter to this office.
Very truly yours, Mn k m
Allen R. Checca Nuclear Licensing Administrator cc: Resident inspector - Byron Resident inspector - Braidwood A.H. Hsia - NRR R.M. Pulsifer - NRR Region 111 Office Office of Nuclear Facility - IDNS 697:1 9107150258 910708
' 0 PDR ADOCK 0500o454 a A, (;,,r.< ll O P
PDR 2
__