Provides Final Results of Analysis of Suppression Pool Temp & Pressure for Limiting LOCA in Regard to Low Pressure ECCS Pump Npsh,Per License Condition Stated
ML20217C256
Person / Time
Site: Monticello 
Issue date: 09/22/1997
From: Hammer M
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
TAC-M97781, NUDOCS 9710010312
Download: ML20217C256 (12)


Text

_ _ _ _ _ _ _ _ - _ _ _ _ _ _ _

o Northem States Power Company Monticello Nuclear oenerating Plant 2807 West Hwy 75 Monticello. Minnesota $5362 9637 September 22,1997 US Nuclear Regulatory Commission Attn: Document Control Desk Washingion, DC 20555 MONTICELLO NUCLEAR GENERATING PLANT Docket No. 50 263 License No. DPR 22 Report of Results from Long Term Containment Analysis to Satisfy License Condition Contained in Appendix C of Facility Operating License No. DPR 22 (TAC No. 97781)

This letter provides the final results of NSP's analysis of the suppression pool temperature and pressure for the limiting LOCA in regard to low pressure ECCS pump NPSH. This letter is being submitted to satisfy a license ce ndition contained in Appendix C (p. C 1) of the MNGP operating license. This license condition is stated as follows.

Submit the results of the additional containment analysis and associated NPSH evaluation discussed above.

In this context, ' additional containment analysis,' refers to an extension of the previous long term LOCA case to the point where containment pressure is at atmospheric levels. The results are being submitted in two attachments as discussed below. No changes to previously submitted analytical methods were made in arriving at these results. There are no changes to the amount of containment overpressure required for NPSH as previously approved by the staff.

j Attachment i supplements GE Report GE NE T23007312,'LOCA Containment Analyses for

//

Use in Evaluation of NPSH for the RHR Core Spray Pumps." The GE report was previously submitted to the staff as Exhibit D to an NSP letter dated June 19,1997. The analysis has been'4S, /

extended to 450,000 seconds or approximately 5.2 days. At 5.2 days, containment pressure has returned to atmospheric levels. is a summary of the overpressyre required for adequate ECCS pump NPSH using environmentalinputs from the long-term containment analysis resuits from Attachment 1. For purposes of continuity, this summary can be considered replacements to pages 19 and 20 of NSP's previously submitted NPSH calculat:on which was submitted as Exhibit E to NSP's letter chted June 19,1997.

9710010312 970922 PDR ADOCK 05000263 gyngs!4 e

eaa 1

__ d

Thk letter contains no new NRC commitments; Please contact Joel Beres, Monticello Licensing, at (612) 2951436 if you require further information, t

MM W Michael F. Hammer Plant Manager Monticello Nuclear Generating Plant c:

Regional Administrator. Ill, NRC NRR Project Manager, NRC Sr. Resident inspector, NRC State of Minnesota. Attn: Kris Sanda J. Silberg, Esq.

Attachments:

Affidavit to the US Nuclear Regulatory Commission Long Term Containment Response for Limiting NPSH Case Containment Pressure Required for Adequate NPSH 4

I I

tr1W J tlCENSE\\JOf ttETTERSmY DOC

_,.-.._.,-,_.~..___.._-.,--,_-.._.--__.,-.-_--_..__..-~..-_,..._.e

UNITED STATES NUCLEAR REGULATORY COMMISSION NORTHERN STATES POWER COMPANY MONTICELLO NUCLEAR GENERATING PLANT DOCKET NO. 50 263 Report of Results from Long Term Containment Analysis to Satisfy License Condition Contained in Appendix C of Facility Operating License No. DPR 22 (TAC No. 97781)

Northern State.s Power Company, a Minnesota corporation, by letter dated September 22,1997 provides the results of additional containment analyses in accordance with the license condition identified herein and contained in Appendix C of Facility Operating License No. DPR 22.

NORTHERN STATES POWER COMPANY By f144t<4t/L, Michael F.' Hammer Plant Manager Monticello Nuclear Generating Plant I

On this 25 day of SenTeder M97 before n:e 9 notary public in and for said County, personally apheared Michael F. Hammer, Plant Manager, Monticello Nuclear Generating Plant, and being first duly sworn acknowledged that he is authorized to execute this document on behalf of Northern States Power Company, and that to the best of his knowledge, information, and belief, the statements made in it are true.

w k h,,

damuelI, Shirey

~

SAMUEL l. SHIREY

~

Notary Public - Minnesota wouRY PuwC.umis01A

^ ##"""#gJan.8hM Sherburne County u, cc a o My Commission Expires January 31,2000 L ~~~^~

" " ~ ~

Snm7 J tICENSEVOELLETTERSG00AY DOC

Long Term Containment Response for Limiting NPSH Case 1

l 1

o

Supp.

Supp.

Chamber Supp.

Supp.

Chamber Pressure Drywell Drywell Chamber Wetwell Pool Chamber Air Partial with Time Pressure Temp.

Pressure Temp.

Temp.

Vapor Pressure leakage 1

(seconds)

(psla)

('F)

(psla)

('F)

('F)

Pressure (psi)

(psta)

(ps0 O.0 14.26 135.0 14.26 90.00 90.0 0.70 13.56 14.26 12.3 41.78 269.9 35.45 208.70 116.4 1.50 33.95 35.45 24.7 38.21 299.0 36.21 212.90 129.9 1,53 34.68 36.21 30.9 38.73 307.3 36.29 213.30 131.7 1.53 34.75 36.28 35.2 1

38.04 302.0 36.31 213.30 132.4 1.54 34.78 36.31 39.2 38.31 300.4 36.33 213.40 132.9 1.54 34.79 36.33 42.3 38.42 298.7 36.34 213.50 133.3 1.54 34.80 36.34 47.7 37.64 263.6 36.32 213.30 133.8 1.54 34.79 36.33 56.7 38.46 264.9 36.40 213.60 134.2 1.54 34.86 36.40 63.6 38.48 264.9 36.48 214.00 134.7 1.54 34.94 36 48 70.6 38.63 265.2 36.57 214.40 135.3 1.55 35.03 36.58 77.8 38.76 265.3 36.6S 214.90 135.9 1.55 35.12 36.67 84.5 38.82 265.5 36.77 215.40 136.4 1.56 35.22 36.77 91.0 38.96 265.7 36.87 215.80 136.9 1.56 35.31 36.87 97.2 38.95 265.7 36.87 215.80 137.2 1.56 35.31 36.87 137.2 38.81 265.4 37.06 216.50 139 3 1.57 35.50 37.07 199.7 38.64 265.2 36.64 213.70 140.8 1.55 35.09 30.64 262.2 37.76 263.8 35.89 209.00 141.0 1.52 34.37 35.89 324.7 37.01 262.6 35.15 204.40 141.1 1.49 33.67 35.15 387.2 36.27 261.4 34.43 199.70 141.1 1.46 32.97 34 42 449.8 35.40 260.0 33.72 195.10 141.2 1.43 32.29 33.71 513.3 33.28 256.1.

33.47 193.30 142.3 1.42 32.05 33.46 591.0 31.40 250.4 31.61 181.90 145.0 1.34 30.27 31.61 742.8 20.95 201.7 21.13 111.30 152.7 1.11 20.02 21.13 1023.2 19.13 184.1 19.28 122.60 156.2 1.36 17.92 19.28 1357.3 18.83 176.2 18.88 129.10 158.8 1.73 17.15 18.88 1701.6 18.71 175.5 18.93 134.50 160.9 2.06 16.86 18 92 2020.1 18.64 173.3 18.86 137.10 162.7 2.30 16.56 18.86 2280.1 18.6S 172.2 18.80 138.50 164.0 2.47 16.32 18.79 2528.6 18.72 171.8 18.91 141.30 165.1 2.63 16.28 18.90 2776.3 18.76 171.3 18.92 143.00 166.2 2.75 16.17 18.91 3024.8 18.79 170.9 18.95 144.30 167.3 2.86 16.09 18.94 3273.3 18.80 170.4 18.93 144.80^

168.2 2.95 15.98 18.93 3524.3 18.81 170.1 19.02 146.20 169.1 3.06 15.96 19.02 3772.8 18.84 169.6 19.01 146.60 170.0 3.15 15.85 19.00 4021.3 18.05 169.1 18.98 146.80 170.8 3.24 15.74 18.97 1

4 4

Supp.

Supp.

Supp.

Chamber Supp=

Chamber Chamber Pressure Drywell Drywell Char ber Wetwell Pool Vapor Air Partial with Time Pressure Temp.

Pressure Temp.

Temp.

Pressure Pressure leakage (seconds)

(psia)

('F)

(psia)

('F)

('F)

(psi)

(psi)

(psia) 4270.6 18.88 169.0 19.06 147.80 171.5 3.35 15.71 19.05 4519.8 18.93 169.1 19.12 148.70 172.2 3.44 15.67 19.10]

4769.1 18.99 169.1 19.17 149.70 172.9 3.53 15.64 19.16 5018.3 19.04 169.2 19.21 150 50 173.6 3.60 15.60 19.19 5267.6 19.09 169.2 19.23 151.20 174.2 3.67 15.56 19.21 5517.0 19.12 169.3 19.33 152.10 174.8 3.74 15.59 19.32 5766.8 19.17 169.4 19.34 152.60 175.4 3.80 15.55 19.33 6017.6 19.20 169.3 19.35 163.20 176.0 3.85 15.50 19.33 6267.6 19.23 169.5 19.43 153.80 176.5 3.91 15.52 19 42 6516.8 19.30 169.6 19.42 154.20 177.0 3.95 15.47 19.40 6766.8 19.32 169.8 19.50 154.80 177.5 4.01 15.49 19.48 7016.8 19.37 170.0 19.57 155.40 178.0 4.06 15.51 19.55 7265.6 19 40 170.0 19.54 155.70 178.4 4.09 15.46 19.53 7515.6 19.46 170.3 19 61 156.10 178.9 4.14 15.47 19.59 7765.6 19.48 170.5 19.67 156.60 179.3 4.18 15.48 19.65 8015.6 19.49 170.5 19.72 157.00 179.7 4.23 15.49 19.70

^

8264.8 19.56 170.7 19.69 157.20 180.1 4.25 15.44 19.67 8514.8 19.60 170.9 19.75 157.60 180.5 4.29 15.45 19.72 4

5 8764.8 19.63 171.1 19.80 158.10 180.9 d.34 15.47 19.79 9014.8 19.65 171.2 19.85 158.40 181.3 4.37 15.48 19.83 9264.8 19.69 171.5 19.90 158.80 151 I 4.41 15.49 19.88 9514 8 19.72 171.6 19.94 159.10 182.0 4.44 15.50 19.92 9764.1 19,77 171.7 19.90 159.20 182.3 4.46 15.44 19.88 10039.1 19.79 171.8 19.95 159.50 182.7 4.50 15.45 19.93 10539.1 19.88 172.3 20.03 160.10 183.3 4 56 15.47 20.01 11039.1 19.96 172.8 l 20.10 160.60 183.9 4.62 15.48 20.08 11539.1 20.02 175.2 20.18 161.20 184.5 4.68 15.50 20.15 12039.1 20.10 173.7 20.25 161.70 185.0 4.74 15.52 20.23 12539.1 20.15 174.0 20.32 162.20 185.6 4.79 15.53 20.29 13039.1 20.23 174.4 20.38 162.60 186.1 4.84 15.54 20.35 13539.1 20.30 174.8 20.44 163.00 186.6 4.88 15.56 20.41 14039.1 20.36 175.2 20.49 163.40 187.1 4.93 15.57 20.47 14539.1 20.42 175.5 20.55 163.70 187.5 4.97 15.58 20.52 15039.1 20.47 175.8 20.60 164.10 188.0 5.01 15.59 20.57 15539.1 20.50 176.0 20.65 164.40 188.4 5.06 15.60 20.62 16039.1 20.55 176.3 20,70 164.80 188.8 5.10 15.61 20.67 16539.1 20.57 176.4 20.75 165.10 189.2 5.13 15.62 20.72 2

Supp.

Supp.

Supp Chamber Supp.

Chamber Chamber Pressure Drywell Drywell Chamber Wetwell Pool Vapor Air Partial with Time Pressure Temp.

Pressure Temp.

Temp.

Pressure Pressure leakage (seconds)

(psia)

('F)

(psia)

('F)

('F)

(psi)

(psi)

(psta) 17039.1 20.61 176.6 20.80 165.40 189.5 5.17 15.63 20.76 17539.1 20.65 170.8 20.84 165.70 189.9 5.20 15.64 20.81 l

18039.1 20.68 177.0 20.88 165.90 190.2 5.24 15.64 20.84 l

18539.1 20.70 177.1 20.92 166.20 190.5 6.27 15.65 20.88 19038.3 20.76 1/7.2 20.88 166.30 190.8 5.28 15.60 20.84 19538.3 20.79 177.4 20.92 166.60 191.1 5.32 1C.60 20.87 20038.3 20.81 177.5 20.96 166.80 191.3 5.35 15.61 20.91 20538.3 20.83 177.6 21.00 167.10 191.5 5.38 15.62 20.95 21038.3 20.85 177.7 21.03 167.30 191.8 5.41 15.63 20.99 21538.3 20.88 177.9 21.07 167.60 192.0 5.44 15.63 21.02 22038.3 20.90 178.0 21.10 167.70 192.2 5.46 15.64 21.06 22538.3 20.92 178.0 21.13 167.90 192.4 5.48 15.64 21.07 23038.3 20.93 178.1 21.15 168.00 192.6 5.50 15.65 21.10 23537.1 20.98 178.2 21.09 168.00 192.7 5.50 15.59 21.04 24037.1 20.99 178.2 21.13 168.30 192.9 5.53 15.60 21.08 24537.1 20.99 178.2 21.15 168.40 193.1 5.55 15.60 21.10 25037.1 21.01 178.3 21.17 168.50 193.2 5.56 15.60 21.11 25537.1 20.99 178.3 21.18 168.60 193.3 5.58 15.61 21.13 26037.1 21.00 178.3 21.20 168.80 193.4 5.59 15.61 21.15 26537.1 21.01 178.3 21.22 168.80 193.5 5.61 15.61 21.16 27036.3 21.04 178.3 21.15 168.80 193.6 5.60 15.55 21.09 27536.3 21.03 178.2 21.17 169.00 193.7 5.62 15.56 21.12 20036.3 21.03 178.2 21.19 169.00 193.8 5.63 15.56 21.13 28536.3 21.03 178.2 21.21 169.20 193.9 5.65 15.56 21.14 29036.3 21.02 178.1 21.22 169.20 193.9 5.66 15.56 21.15 29536.3 21.01 178.0 21.23 169.30 194.0 5.67 15.56 21.16 30035.6 21.04 178.0 21.16 169.20 194.0 5.65 15.50 21.09 30535.6 21.03 177.9 21.17 169.30 194.1 5.67 15.51 21.11 31035.6 21.03 177.9 21.18 169.40 U4.1 5.68 15.51 21.12 31535 6 21.02 177.9 21.19 169.40 1 94.1 5.68 16.51 21.13 32035.6 21.02 177.9 21.20 169.50 1 ' 4.1 5.69 15.51 21.13 32535.6 21.00 177.8 21.20 169.50

.94.2 5.69 15.51 21.13 33035.6 21.00 177.7 21.21 169.50 194.2 5.70 15.51 21.13 33534.8 20.99 177.5 21.13 569.40 194.2 5.68 15 45 21.06 34034.8 21.00 177.5 21.14 169.50 194.2 5.69 15.45 21.06 34534.8 20.97 177.4 21.14 169.50 194.2 5.69 15.45 21.07

' _5034.8 20.97 177.3 21.15 169.50 194.1 5,69 15.45 21.07 3

3

l Supp.

Supp.

Supp, Chamber Supp.

Chamber Chamber Pressure Drywell Drywell Chamber Wetwell Prol Vapor Air Partial with Time Pressure Temp.

Pressure Temp.

Temp.

Pressure Pret.sure leakage (seconds)

(psia)

('F)

(psia)

('F)

('F)

(psi)

(psi)

(psia)

{

35534.8 20.96 177.3 21.15 169.50 194.1 5.70 15 45 21.07 i

36034.8 20.94 177.2 21.15 169.60 194.1 5.70 15.45 21.07 365;.,4.1 20.96 177.1 21.07 169.40 194.1 5.68 15.39 20.99 I

l 37034.1 20.93 176.9 21.07 169.40 194.0 5.68 15.39 20.99

)

37534.1 20.94 176.9 21.08 169 50 194.0 5.09 15.39 20.99 38034.1 20.91 176.8 21.08 169.50 194.0 5.69 15.39 21.00 38534.1 20.89 176.7 21.08 169.50 193.9 5.69 15.39 21.00 39033.6 20.87 176.6 21.08 169.50 193.9 5.69 15.39 20.99 39533.6 20.87 176.0 21.08 169.50 193.9 5.69 15.39 20.99 40231.8 20.88 176.4 20.99 169.30 193.8 5.67 15.33 20.91 42730.8 20.78 175.8 20.99 169.30 193.5 5.67 15.32 20.90 45228.1 20.70 175.2 20.9Q 169.00 193.2 5.64 15.26 20.81 47727.3 20.66 174.6 20.80 168.50 192.8 5.61 15.18 2r'.69 i

50227.3 20.60 174.2 20.77 168.30 192.3 5.61 15.17 20.67 52727.3 20.52 173.8 20.72 167.80 191.8 5.59 15.13 20.61 1

55226.6 20.46 173.2 20.58 167.20 191.3 5.56 15.03 20.47 l

57931.3 20.37 172.7 20.53 166.70 190.6 5.54 14.99 20.41 I

61531.3 20.24 171.9 20.41 166.10 189.6 5.47 14.94 20.28 65333.8 20.09 171.0 20.20 165.30 188.6 5.37 14.89 20.13 69122.8 19.95

'70.1 20.1 I 164.50 187.6 5.28 14.84 19.97 73014.8 19.82 169.3 19.97 163.70 186.5 5.18 14 10 19.82 77042.1 19.67 168.4 '

I? 83 162.90 185.4 5.08 14.75 19.67 81058.3 19.53 167.5 19.68 162.00 184.3 4.98 14.70 19.51 85073.8 19.40 166.6 19.54 161.20 183.2 4.88 14.66 19.36 r

89202.3 19.29 165.9 19.41 160.40 182.2 4.79 14.63 19.24 93382.8 19.21 165.3 19.32 159.80 181.4 4.72 14.61 19.14 97520.3 19.08 164.4 19.20 159.10 180.5 4.64 14.56 19.01 101708.8 18.93 163.4 19.05 158.30 179.3 4.55 14.51 18.85 105929.3 18.80 162.5 18.92 157.40 178.1 4.45 14.47 18.71 110184.6 18.67 161.6 18.78 156.50 177.0 4.36 14.43 18.57 114472.1 18.54 160.6 10.66 155.60 175.9 4.27 14 39 18.43 118690.6 18.42 159.8 18.54 154.80 174.9 4.19 14.35 18.30 i

123061.6 18.32 159.0 18.43 154.10 173.9 4.11 14.32 16.19 127493.1 18.22 158.2 18.32 153.30 172.9 4.04 14.29 18.07 131890.3 18.12 157.5 18.22 152.60 172.0 3.97 14.26 17.96 136297.6 18.02 156.8 18.12 151.90 171.1 3.90 14.23 17.86 4

~,. _,..-

..r-,

1 C

Supp.

Supp.

Supp.

Chamber Supp.

Chamber Chamber Pressure Drywell Drywell Chamber Wetwell Pool Vapor Air Partial with Time Pressure Temp.

Pressure Temp.

Temp.

Pressure Pressure leakage (seconds)

(psia)

('F)

(psia)

('F)

(*F)

(psi)

(psi)

(psia) 140754.6 17.93 156.0 18.03 151.20 170.2 3.83 14.20 17.75 145067.6 17.83 155.2 17.94 150.60 169.3 3.77 14.17 17.66 149432.6 17.75 104.6 17.85 149.90 168.5 3.71 14.14 17.56 153771.1 17.68 154 0 17.77 149.30 167.7 3.66 14.11 17.47 158022.1 17.59 153.4 17.69 148.70 166.9 3.61 14.09 17.39 162329.1 17.52 152.7 17.61 148.20 166.2 3.55 14.06 17.30 166532.1 17.46 152.2 17.54 147.60 165.4 l 3.50 14.04 17.22 170966.6 17.38 151.5 17.47 147.00 164.7 l 3.45 14.01 17.13 175313.1 l 17.31 150.9 17.39 146.40 163.9 3.41 13.99 17.05 179776.1 l 17.23 150.3 17.32 145.90 163.2 3.36 13.97 16.98 184252.11 17.17 149.8 17.26 145.40 162.5 3.31 13.95 16.91 188788.6 17.12 143.3 17.20 144.90 161.8 3.27 13.93 16.84 193269.1 17.06 148.8 17.14 144.40 101.2 3.23 13.91 16.77 197747.6 17.01 148.3 17.08 143.90 160.6 3.20 13.89 16.70-

,202286.1 16.96 147.8 17.03 143.50 160.0 3.16 13.87 16.64 206711.1 16.89 147.3 16.98 143.10 159.5 3.13 13.85 16.58 211267.1 16.86 146.9 16.93 142.60 158.9 3.09 13.84 16.53 215777.6 16.80 146.4 16.88 142.20 158.4 3.06 13.82 16.47 220237.1 16.77 146.1 16.84 141.80 157.9 3.03 13.81 16.42 224807.6 16.72 145.7 16.7S 141.50 157.4 3.00 13.79 16.36 229264.1 16.66 145.2 16.75 141.10 156.9 2.97 13.78 16.31 233897.6 16.63 144.8 - l 16.70 140.70 156.4 2.94 13.76 16.25 238401.6 16.59 144.4 16.66 140.30 155.9 2.92 13.75 16.21

(

243072.6 16.53 144.0 16.62 139.90 155.4 l 2.89 13.73 16.15 247726.1 16.50 143.6 16.58 139.60 154.9 2.86 13.72 16.11 252305.1 16.45 143.2 16.54 139.20 154.4 2.83 13.70 16.05 256903.1 16.42 142.8 16.50 138.80 153.9 2.81 13.69 16.01

~

261579.6 16.38 142.4 16.45 138.50 153.4 2.78 13.68 15.96 266335.1 16.35 142.0 16.41 138.10 153.0 2.75 13.66 15.91 271040.1 16.31 141.7 16.38 137.70 152.5 2.73 13.65 15.86 275727.1 16.28 141.3 16.34 137.40 152.1 2.70 13.64 15.82 l

280382.6. 16.24-141.0 16.31 13'7.10 151.7 2.68 13.63 15.78 285022.6 16.20 140.6 l 16.28 136.80 151.3 2.66 13.62 15.74 289777.6 16.17 140.3 l 16.25 136.50 150.9 2.64 13.61 15.70 294444.6 16.15 140.1 16.22 136.20 150.5 2.62 13.60 15.66 299105.1 16.12 139.8 16.19 136.00 150.2 2.60 13.59 15.63 5

l l

1

Supp.

Supp.

Supp.

Chamber Supp.

Chamber Chamber Pressure Dr/wt.'l Drywell Chamber Wetwell Pool Vapor Air Partial with Time Prest e Temp.

Pressure Temp.

Temp.

Pressure Pressure leakage (seconds)

(psia)

('F)

(psia)

(*F)

(*F)

(psi)

(psi)

(psia) 303795.6 16.10 139.5 16.16 135.70 149.8 2.59 13.58 15.59 308586.1 16.07 139.2 16.13 135.40 149.5 2.57 13.57 15.5G 313371.6 16.04 139.0 16.11 135.20 149.1 2.55 13.56 15.52 318164.6 16.02 138.7 16.08 134.90 148.8 2.53 13.55 15.49 322923.1 15.99 138.4 16.06 13e70 148.5 2.52 13.54 15.45 327649.6 15.96 138.1 16.03 "

134.40 148.2 2.50 13.53 15.42

^

332281.6 15.95 137.9 16.01 134.20 147.9 2.49 13.52 15.38 337088.6 15.92 137.6 15.99 134.00 147.6 2.47 13.51 15.35 341750.6 15.88 137.3 15.96 133.70 147.3 2.46 13.51 15.33 346513.1 15.87 137.1 15.94 133.50 146.9 2.44 13.50 15.29 351343.6 15.85 136.9 15.92 133.30 146.6 2.43 13.49 15.26 356046.6 15.83 136.6 15.89 133.10 146.3 2.41 13.48 15.23 360769.1 15.80 136.4 15.87 132.80 146.1 2.40 13.47 15.19 365544.1 15.79 136.2 15.85 132.60 145.8 2.38 13.47 15.17 370354.1 15.76 135.9 15.83 132.40 145.5 2.37 13.46 15.14 375219.1 15.74 135.7 15.81 132.20 145.2 2.36 13.45 15.11 380113.6 15.72 135.4 15.78 131.00 144.9 2,34 13.44 15.07 384912.1 15.70 135.2 15.76 131.70 144.6 2.33 13.43 15.04 389789.1 15.68 134.9 15.74 131.50 144.3 2.31 13.43 15.02 394646.1 15.64 134.6 15.72 131.30 144.0 2.30 13.42 14.98 399687.1 15.61 134.4 15.70 131.00 143.7 2.29 13.41 14.95 404597.6 15.62 134.2 15.68 130 80 143.4 2.27 13.40 14.92 409484.1 15.59 134.0 15.66 130.60 143.1 2.26 13.40 14.90 414516.1 15.56 133.7 15.64 130.40 142.8 2.25 13.39 14.87 419565.6 15.55 133.6 15.62 130.20 142.6 2.24 13.38 14.84 42.S30.6 15.53 133.3 15.60 130.00 142.3 2.22 13.38 14.81 429735.6 15.52 133.2 15.58 129.80 142.0 2.21 13.37 14.78 434771.6 15.48 132.9 15.56 129.60 141.8 2.20 13.36 14.75 439842.6 15.48 132.7 15.55 129.40 141.6 2.19 13.36 14.73 444849.6 15.46 132.5 15.53 129.20 141.3 2.18 13.35 14.70 449895.1 15.46 132.4 15.51 129.10 141.1 2.17 13.35 14.68 450000.6 15.45 132.3 l 15.51 129.00 141.1 2.17 13.34 14.68 6

a

l Containment Pressure Required for Adequate NPSH

t l

COf1TAlfJMEfJT PRESSURE REQUIRED FOR ADEOUATE CORE SPRAY fJPSH DURIf4G TriE LONG TERM PHASE OF THE DBA LOCA l

Pump Constans sperAc Vas<n Atmosphereic Sudum (Ps/Sw

  • Required Wesy4 Pressure Presount #ib)

It/Sg P essure Velocey V'Q32 2))

Corsairwnent Tome (sec)

Temperature (F)

(Sw) (Ity11') (Pha) (bit') tha/Sw (It )

(b1t2)

(f )

(pssg)

(ft/sec)

(ft }

FJPSHA (ft )

NPSHR (ft )

System Pump Pressure (psig) 7428 152 7 61 1378 572 3:40 9 3619 2u53 44 33 587I 2 108 8 688 61311 30 3632 29 "B"CS

-c5905 2280 8 864 60 9125 750 5856 12 3224 2053 44 33 71 3 2 208 8688 6 :555 27 5444 29

  • B CS 06305 6017 6 I76 60 6575 989 1360 16 3069 2053 44 33 8530 2 108 8 688 6 3764 23 7225 29
  • B" CS 2 2662 150399 188 60 3901 1289 3 % 3 21 3348 2053 44 34 0u29 2.808 8 688 6 8986 18 8674 29

'B* CS 4 3894 21538 ?

192 60 2954 1403 5680 23 2782 2053 44 34 0563 2 808 8 686 6 20G5 d6 9846 29

  • B"CS 52058 l

_3n035 6 194 60 2482 1464 8920 24 3027 2uS3 44 34 0810 2106 8 688 6 2104 15 9908 29

  • B* CS 5 6356 33534 8 194 2 60 2439 le70 4440 2 108 8 688 6 2083 16 4910 29

~B* CS 54I89 465281 193 60 2736 to33 E450

. 24 4081 2053 44

_34 0855 2 108 8 688 6 2108 15 8088 29 "B"CS 56801 237859 2053 44 34 0686 57027 3 192 60 2954 1403 5680 23 2782 2053 44 34 0563 2 108 8 6R8 6 2065 16 9846 29 "B" CS 5 2051 71151 1 187 60 4120 1260 8640 20 8715 2053 44 33 9906 2 108 8 688 6 1968 19 3163 29

  • B' CS 4 1950 tot 108 8 179 3 60 53se 1064 9%2O 175779 2053 44 33 8937 2 108 8 6ee 6 1824 22 4982 29 "B CS 28166 197747 6 360 6 60 9908 672 6280 1e3588 2053 44 33 6735 2 108 8 688 6 1499 28 4653 29 "B* CS O2316 3w6871 le3 7 61 309I 4572920 7 4588 2053 44 33 4932 2 108 8 688 6 1232 32 1577 29

-1 3679 COf1TAlfJMEfJT PRESSURE REQUIRED FOR ADEOUATE RHR NPSH DURifJG THE LOfJG TERM PHASE OF THE DBA LOCA rump cor eans Speas.c vaixw game,,%

Si, wm (Pg/Se a p,,g l

Weeght Pressure p,,wnepeg geb/Sw Pressure Vetrxdy V'Q32.2))

Con 6airwnent inae (ser)

Temperasure (F)

(S.) (st>16 {tha}ytgj Hva/S.E (Itwitz)

(8 )

3:sia)

'It/sec)

(ft )

64PSHA (f1 )

NP3HR (ft )

System Pump Pressure (ppg) r 742 8 152 7 61.1378 572 3140 9 361s 2053 44 33 5871 2 399 9 315 6 9978 31 2238 26

'B'RHR

-2 2630 22801 164 60 9825 750 5856 12 3224 2053 44 33 7813 2 399 9 315 70187 28 4077 26

  • B"FutR

-10430 60176 176 60 6575 989 1360 16 3069 _

2053 44 33 8530 2 399 9 315 7 0425 24 5887 26

  • B'RHR 068to I$0391 888 (9 3901 1288 368_G 21 3349 2053 44 34 0029 2 399 9 315 7 0678 19 7366 26
  • B*FntR 2 7133 21538 3 192 60 2954 3403 56RO 23 2782 2053 44 34 0563

__ 2 399 9 315 7 0767 17 8549 26 "B"RHR 3 5285 3H035 6 194 60 2482 8464 1920 24 3027 2053 44

}s 0630_

2 399 9 315 7 0812 16 8616 26

  • B*RHR 3 95R8 3M34 8 194 2 80 2439 1470 4400 24 4081 2053 44 34 0855 2 399 9 315 7OR16 16 7590 26 "B*FWtR 40032 465281 893 60 2736 8433 6640 23 7859 205344 34 0686 2 399 9 315 7 0788 iT3615 26

~B*RHR 3 7422 52027 3 192 60 2954 14035680 23 2782 2053 44 34 0563 2 399 9 315 7 0767 17 8549 26

  • B"RHR 3 5285 7 t$11 187 60 4120 1260 8640 20 87II 2053 44 33 99816 2399 9 315 7 0657 20 1852 26
  • B*RHR 2 5190 tot 1088 179 3 60 5848 1064 9520 17 5779 2053 44 338937 2 399 9 315 7.0494 23 3652 26
  • B' RHR 1.1484 897747 6 560 6 60 9608 692 6280 183581 2053 44 3J 6735 2 399 9 315 7 0123 29 3278 26
  • B*F#4R

-t4416 39w471 143 7 613n91 457 2920 7.4588 2053 44 33 4932 2 399 9 315 6 9820 33 0165 26

  • B*ID1R 3 0395 l

f I

I l

I I

l l

6 9

6

-