ATTACIBIElff. 2 CATAWBA NUCLEAR STATION ENVIRONMENTAL PROTECTION PLAN 1986 SOUND LEVEL SURVEY fN A$Ed SN a

ATTACIDENT 2 Introduction Duke Power Company is required, by the United States Nuclear Regulatory Commission (USNRC), to submit an annual environmental operating report documenting the impact of Catawba Nuclear Station (CNS) on the environment. As stated in the Catawba Environmental Protection Plan (EPP), Duke Power Company will conduct an operational' phase ambient noise survey as part of the report.

This report documents the current status of the Catawba Nuclear Station Noise Survey and presents the data collected in the winter of 1986 during Unit 1 operation.

The CNS EPP specifies that data is to be collected during both one and two Unit operation.

Also, sound level data must be collected for both winter and summer due to the change in the acoustical environment. Two Unit operational sound level data was planned for the summer of 1986; however, due to the unavailability of both Units operating simultaneously two Unit operational summer data is scheduled for the summer of 1987.

Materials and Methods The methodology used in this study is described in the Environmental Study Design Document titled - Catawba Nuclear Station Noise Survey (Keener, 1985).

Results Appendix A lists the continuous noise data collected for each site by date.

The data consist of hourly A-weighted L99, L90, L50, L10, L1, and LMAX noise levels for Locations A, B, C, D, and E.

Plots of the L1, L10, and L90 sound levels for each site are presented in Figures 1 through 5.

Conclusion Comparison of the 1986 Unit 1 operational winter data with pre-operational data presented in the 1985 Annual Non-Radiological Environmental Operating Report indicates that the sound level data presented in this report is within the observed values presented earlier.

A final report will be written as specified in the CNS EPP once monitoring is complete for two Unit operation.

i l

r s

Reference

.1.

Keener, R.

N. Environmental study design document:

Catawba Nuclear Station Noise Survey.

Duke Power Company, Production Environmental Services Res. Rept.

PET /85-14.

1985: 6p.

em

L90,L10,And Li,For Site A 01/16/86-01/18/86 Sound Level (db(A))

70-60-50 -

i, 20-10 -

0 1900 2400 0500 1000 1500 2000 0100 Figure 1. Variation in L90, L10, and L1 Sound Level Distribution for CilS Noise lionitorinq Site A.

L90,L10,And Li, For Site B 01/30/86-02/03/86 Sound Level (db (A))

70-L10 50 -

L90 40-30-20-10 -

0 1600 0100 1100 2100 0700 1700 0300 1300 2300 0800 Figure 2.

Variation in L90, L10 and L1 Sound Level Distribution for CriS Noise Monitoring Site B.

L90,L10,And Li, For Site C 01/23/86-01/25/86 Sound Level (db(A))

80 -

0 40 -

L90 30-20-10-0 1700 2200 0300 0800 1300 1800 2300 0400 0900 Figure 3. Variation in LOO, L10, and L1 Sound Level Distribution for CflS Noise tionitoring Site C.

L90,L10,And Li, For Site 0 01/20/86-01/22/86 sound g lim W l L1 60 -

E-8 L10 L90 40-30 -

20-10 -

0 i

1500 2000 0100 0600 1100 1600 2100 0200 0700 Fiquro 4. Variation in L90, L10, and L1 Sound Level Distribution for i

CNS Noise Monitorinq Site D.

I I

I

L90,L10,AE Li,For Site E 02/28/86-03/03/86 Sound Level (db(A))

70-l 60 -

50-z.

LI 40-VL10 30 -

Lgo 20-l 10-l 0

1300 2200 0800 1800 0400 1400 2400 l

Figure 5.

Variation in L90, L10, and L1 Sound Level Distribution for CNS Noise Monitoring Site E.

Appendix A - 1986 winter continuous noise data - hourly values of L99, L90, L50, L10, L1, and LMAX by Site.

it m

l l

l l

t.

SITE A

.DATE-HOUR L99 L90

-L50 L10 g

LMAX 1/16/86 1500 34,

35 38 48 57 70 1/16/86 1600 34 35 40 46 56 61 1/16/86 1700 32 33 35 40 48 55 1/16/86 1800 32 34 36

-48 59 69 1/16/86 1900 29 32 35 47 57 68 1/16/86 2000 30 31 35 41 50 57 1/16/86 2100 29 31 34 41 51 55 1/16/86

, 2200 30 31 34 41 51 55 1/16/86 2300 30 31 33 37 45 52 1/16/86 2400 32 33 34 36 42 50 1/17/86 0100 32 35 38 43 57 64 1/17/86 0200 33 36 39 41 47 56 1/17/86 0300 35 36 40 41 43 47 1/17/86 0400 37 38 41 45 44 49 1/17/86 0500 36 37 39 41 -

45 55 1/17/86 0600 30 33 36 37 40 46 0700 31 32 34 39 44 53 1/17/8G 1/17/86 0800 34 36 40 45 60 72 1/17/86 0900 36 38 42 49 58 69 1/17/86-1000 34 36 39 50 60 72 1/17/86 1100 35 37 40

- 48 60 75 1/17/86 1200' 34 36 39 47 56 70 1/17/86 1300 34 35 39 47 61 73

Site A, continu:d DATE HOUR L99 L90 L50 L10 L1 LMAX 1/17/86 1400

-34 35 38 45 54 70 1/17/86 1500 33 34 38 44 60 73 1/17/86 1600 33

  • 36 40 50 60 65 1/17/86 1700 31 32 35 44 55 62 1/17/86 1800 35 37 39 45 54 62 1/17/86 1900 37 38 39 43 53 57 1/17/86 2000 38 39 41 43 47 52 1/17/86 2100 38 39 38 41 45 48 1/17/86 2200 31 32 35 42 47 51 1/17/86 2300 30 31 35 39 50 56 1/17/86 2400 34 35 38 39 42 53 1/18/86 0100 35 36 37 39 41 47

~

1/18/86 0200 36 37 39 42 43 51 1/18/86 0300 35 35 38 39 49 70 1/18/86 0400 32 33 36 38 40 52 6

d i

4 re m ww w

w w

p-SITE B DATE HOUR L99 L90 L50 L1C L1 LMAX 1/30/86 1600.

33, 34 37 43 56 66 1/30/86 1700 34 34 38 47 54 62 1/30/86 1800 33 35 41 47 60 66 1/30/86 1900 34 36 41 45 55 60 1/30/86 2000 39 42 43 48 56 63 1/30/86 2100 39 40 42 45 52 59 1/30/86 2200 39 40 44 46 56 65 1/30/86 2300 42 42 44 46 59 63 1/30/86 2400 42 44 45 46 49 54 1/31/86 0100 44 44 46 47 50 53 1/31/86 0200 43 44 46 47 48 55 1/31/86 0300 44 45 46 47 48 53 1/31/86 0400 39 40 44 45 49 57 1/31/86 0500 40 40 41 42 42 52 1/31/86 0600 32 39 40 42 "

50 58 1/31/86 0700 36 40 41 42 50 58 1/31/86 0800 41 42 44 50 60 72 1/31/86 0900 37 38 42 54 62 66 1/31/86 1000 36 38 42 49 56 60 1/31/86 1100 36 37 40 47 56 62 1/31/86 1200 37 39 41 46 54 66 1/31/86 1300 36 37 39 47 62 72 1/31/86 1400 36 38 42 48 63 76 1/31/86 1500 36 37 41 49 62 71

~

. Sit 9 B, continu;d DATE HOUR L99 L90 L50

'L10 L1 LMAX 1/31/86 1600 35 37 41 51 59 66 1/31/86 1700 35 36 41 48 52 57 1/31/86 1800 35 37 42 49 63 70 1/31/86 1900 36 37 41 45 52 58 1/31/86 2000 35 36 41 44 50 56 1/31/86 2100 38 39 42 45 50 56 1/31/86 2200 38 40 43 45 55 61 1/31/86 2300 38 39 41 42 43 52 1/31/86 2400 38 39 42 43 44 52 2/1/86 0100 42 43 44 45 50 53 2/1/86 0200 35 36 42 43 44 53 2/1/86 0300 41 42 44.

46 46 53 2/1/86 0400 41 42 43 45 50 68 2/1/86 0500 42 42 43 44 45 68 2/1/86 0600 40 42 43 44.

44 52 2/1/86 0700 39 42 43 44 48 63 2/1/86 0800 42 43 46 51 59 63 2/1/86 0900 41 43 46 55 62 65 2/1/86 1000 40 42 44 48 54 65 l

t 2/1/86 1100 39 40 44 52 61

-65 2/1/86 1200 37 39 43 49 58 64 2/1/86 1300 36 38 42 50 57 65 l

2/1/86 1400 38 39 42 51 63 70 2/1/86 1500 37 39 42 51 61 67 2/1/86 1600 35 37 40 47 57 72 2/1/86 1700 35 36 39 48 57 60 I

l

Site B, continu:d DATE' HOUR L99' L90 L50 L10 L1 LMAX 2/1/86 1100' 39 40 44 52 61 65 2/1/86 1200 37 39 43 49 58 64 2/1/86 1300 36 ' '

38 42 50 57 65 2/1/86 1400 38 39 42 51 63 70 2/1/86 1500 37 39

~42 51 61 67 2/1/86 1600 35 37 40 47 57 72 2/1/86 1700 35 36 39 48 57 60 2/1/86 1800 36 37 39 45 54 63 2/1/86 1900 35 36 38 43 55 61 2/1/86 2000 35 36 39 42 46 55 2/1/86 2100 36 37 41 43 51 57

~

2/1/86 2200 39 40 43 44 46 52 2/1/86 2300-36-39 41 44 51 69 2/2/86' 2400 37 38 41 44 61 72 2/2/86 0100 35 36 38 41 48 66' 6

JHs 40 42 44 52-3 2/2/86 0200 2/2/86 0300 38 39 41 43 44 57 2/2/86 0400 39 40 42 44 54 70 2/2/86 0500 39 40-43 44 46 53 2/2/86 0600 39 41 44 46 48 53 2/2/86 0700 39 40 42 44 56 64 2/2/86 0800 41 42 45 51 57 61 2/2/86 0900 41 42 45 54 16 3 69 2/2/86 1000 41 42 45 52 63 71 2/2/86 1100 42 44 46 51 57 63 2/2/86 1200 43 45 47 51 58 66

Site B, continu:d

!DATE HOUR L99 L90 L50

~ L10 M

LMAX T2/2/86 1300-43 45-

'47 51 56 64 2/2/86 1400 40 42 45 53 64 72' u --

2/2/86 1500 39 '"

40 43 48 58 68-2/2/86 1600 39 41 44

-50' 63 72

-2/2/86 1700 38 39 43 49-56 63 2/2/86 1800 37 38 40 48 66 72 2/2/86 1900

'36 37 40 46 55.

60 2/2/86~

2000 37 38 39 44 50 59 2/2/86

2100 37 38 40 44 48 54 2/2/86 2200 40 41 42-45 60 66 2/2/86 2300 37 39 42 47 54 60 2/3/86 2400 36:

37 38

-39 41 52 2/3/86 0100

'37 37-39 40 42 56 2/3/86 0200 36 37 39 41-42-63 2/3/86.

0300 34 35

'37 39 41 52 2/3/86 0400 34 35 36

-38 37 52

'2/3/86-0500 34 35 37 38-40 52 l

2/3/86 0600 33 34 37 40 42 51 2/3/86.

0700 36 36 37 40 47 62 l-

.2/3/86

-0800 39 41 43 52 60 63' L

L p

t L

p SITE C DATE HOUR L99 L90 L50 L10 L1 LMAX 1/23/86 1500

. 37,,

40 49 63 73 87 1/23/86 1600 40 44 51 63 70 75 1/23/86 1700 43 48 57 66 71 77 1/23/86 1800 37 44 52 64 69 86 1/23/86 1900 36 41 55 64 68 74 1/23/86 2000 33 37 50 62 68 75 1/23/86 2100 33 35 44 58 65 75 1/23/86 2200 36 38 46 59 66 71 1/23/86 2300 33 35 40 55 a65 71 1/23/86 2400 33 34 40 55 65 76 1/24/86 0100 30 31 35 53 66 72 1/24/86 0200 28 29 31 40 62 70 1/24/86 0300 31 32 34 42 61 72 1/24/86 0400 32 33 34 40 63 73 1/24/86' 0500 33 34 36 47 -

63 67 1/24/86 0600 33 35 37 57 66 73 1/24/86 0700 36 42 56 65 71 78 1/24/86 0800 41 48 59 66 71 76 1/24/86 0900 39 41 52 64 71 79 1/24/86 1000 39 43 51 63 71 79 1/24/86 1100 43 46 51 62 69 76 1/24/86 1200 37 41 48 62 70 79 1/24/86 1300 39 42 50 63 70 missing 1/24/86 1400 38 44 51 62 69 77

Sita C, continu;d DATE HOUR L99 L90 L50 L10 L1 LMAX 1/24/86 1500 38 43 50 63 72 77 1/24/86 1600 41 46 53 64 71 77 1/24/86 1700 42

47 58 66 71 76 1/24/86 1800 35 43 52 64 70 90 1/24/86 1900 35 41 52 63 68 79 1/24/86 2000 33 40 50 62 66 72 1/24/86 2100 31 35 46 59 67 73 1/24/86 2200 31 33 45 60 66 75 1/24/86 2300 32 35 41 59 65 70 1/24/86 2400 34 35 39 57 66 77 1/25/86 0100 34 35 38 52 65 72 1/25/86 0200 32 33 35 43 62 69 1/25/86 0300 33 34 36 45 64 73 1/25/86-0400 32 33 35 40 60 69 1/25/86 0500 32 34 36 43 62 77 1/25/86 0600 33 35 38 52 65 74 1/25/86 0700 33 34 42 61 66 73 1/25/86 0800 33 35 42 59 67 76 1/25/86 0900 34 36 43 59 68 79 1/25/86 1000 34 37 45 60 68 79 l

l l

l l

l i_

SITE D DATE HOUR L99 L90 L50 L10 L1 LMAX 1/20/86 1100 38,,

40 45 53 67 76.

1/20/86 1200 39 41 45 50 56 65 1/20/86 1300 38 39.

44 50 60 67 1/20/86 1400 36 39 45 51 56 61 1/20/86-1500 35 37 41 48 53 57 1/20/86 1600 36 39 47 55 61 68 1/20/86 1700 38 39 44 48 54 66 1/20/86 1800 33 35 41 51 61 68 1/20/86 1900 31 32 35 41 51 58

.1/20/86 2000 31 32 39 45 62 71 1/20/86 2100 32 33 39 43 53 60 1/20/86-2200 31 33 38 44 62 70 1/20/86 2300 32 33 39 42 55 64 1/20/86 2400 31 33 40 42 45 55 1/21/86 0100 36 37 41 42 -

46 54 1/21/86 0200 34 36 41 41 44 55 l

1/21/86 0300 36 37 41 42 42 55 1/21/86 0400 36 37 41 42 42 54 1/21/86 0500 37 39 41 42 47 54 1/21/86 0600 37 38 41 43 45 55 1/21/86 0700 37 38 42 45 54 63 1/21/86 0800 38 39 43 47 55 60 f

1/21/86 0900 37 42 46 54 65 70 1/21/86 1000 38 40 43 51 60 70

- Site 0,- continu:d

'OATE HOUR L99 L90 L50 L10 L1 LMAX 1/21/86 1100 35 37 43 49 59 63 1/21/86 1200 34 36 41 49 62 67 1/21/86 1300' 33 "

34 38 53 65 70 1/21/86 1400 33 36 42 52 60 64 1/21/86 1500 34 35 42 52 58 67 1/21/86 1600 33 35 43 53 62 70 1/21/86 1700 33 34 41 53 66 72 1/21/86 1800 33 34 40 51 60 63 1/21/86 1900 33-35 40 46 60 65 1/21/86 2000 33 35 39 47 65 75 1/21/86 2100 34 35 39 45 56 59 1/21/86 2200 33 34 39 46 57 66

~

1/21/86 2300 34 35 37 42 64 69 1/21/86 2400 34 34 39 42 48 55 1/22/86 0100 35 36 41 45 52 56 1/22/86 0200 35 36 39 42 43 55 1/22/86 0300 36 37 41 42 42 54 1/22/86 0400 35 37 40 42 44 54 1/22/86 0500 33 34 41 41 42 55 1/22/86 0600 35 38 41 42 68 71 1/22/86 0700 38 39 42 44 49 63 1/22/86 0800 39 41 43 48 60 69 l

i.

SITE E DATE HOUR L99 L90 L50 L10 L1 LMAX 2/28/86 1300 29 30 36 50 58 64 2/28/86 1400 29 30 36 52 62 68

-2/28/86 1500 29 30 38 53 64 68 2/28/86 1600 30 31 35 48 59 72 2/28/86 1700 30 32 40 55 63 70 2/28/86 1800 28 29 33 51 59 64 2/28/86 1900 28 29 36 52 63 69 2/28/86 2000 28 29 32 41 64 81 2/28/86 2100 30 30 32 41 64 81 2/28/86 2200 29 30 35 54 61 71 2/28/86 2300 29 30 32 34 41 65 2/28/86 2400 30 31 32 36 66 77 3/1/86 0100 29 30 31 33 42 47 3/1/86 0200 28 29 31 34 36 44 3/1/86 0300 28 28 29 30 -

33 37 3/1/86-0400 28 29 30 32 46-58 3/1/86 0500 27 27 28 29 30 35 3/1/86 0600 26 27 28 29 30 35 3/1/86 0700 27 28 29 36 51 57 3/1/86 0800 29 30 32 38 55 62 i

3/1/86 0900 31 33 37 51 61 66 3/1/86 1000 32 33 36 48 64 69 3/1/86 1100 32 34 40 51 61 67 l

3/1/86 1200 34 38 42 48 58 66 l

l

Site E,.centinued DATE

-HOUR' L99 L90 L50 L10 L1 LMAX 3/1/86~

1300 33 35 40 51' 57 66

<3/1/86 1400-33 37 41 49 58 69 3/1/86 1500 33 "

35 42 48 59 63 3/1/86 1600 40 41 44 52 61 69 3/1/86 1700 36 39 43 50 56 68 3/1/86 1800

-34 36 37 46

.54 61 3/1/86 1900 31 38 39 46 58 63 3/1/86 2000 31 32 36 42 51 57 3/1/86 2100 36 37 39 44 50 57 3/1/86 2200 36 37 39 50 60 69 3/1/86 2300 36 37 39 42 49 59 3/1/86 2400 38 40=

43 45 48 52

~

3/2/86 0100 37 38 41 44 47 50 3/2/86-0200 31 32 34 37 44 54 3/2/86 0300 30 30 32 34 36 48 3/2/86 0400 30 31 33 36 38 41 3/2/86 0500 30 31 32 34 36 63

[

3/2/86 0600 29 30 32 35 41 50 I

3/2/86L 0700 29 29 30 33 35 38 3/2/86 0800 30 32 36 46 58 74 3/2/86 0900 29 32 37 51 60 75 j;

3/2/86 1000 29 30 36 46 61 66 3/2/86 1100 30 31 36 46 61 66 i

3/2/86 1200 32 33 39 49 59 66 3/2/86 1300 32 37 44 56 63 73 3/2/86.

1400 38 41 44 53 60 69

e Site E, continued

'OATE HOUR L99 L90 L50 L10 L1 LMAX.

3/2/86 1500 38 40-44' 52 62 66 3/2/86-1600 36 41 45 55 67 69 3/2/86 1700 35 ' '

39 43 50 60 65 3/2/86 1800 34 36 39 49 62 67 3/2/86 1900 31 33 36 47 54 66 3/2/86 2000 29 30 34 45 55 63 3/2/8G 2100 29 31 35 44 49 54 3/2/86 2200 33 34 36 40 44 49 3/2/86 2300 35 37 46 54 58 63

~3/2/86 2400 30 32 41 54 59 61 3/3/86-0100 30 31 35 38 40 47 3/3/86 0200 30 31 33 35 38 45

~3/3/86 0300 29 30 32 37 41 48 i