ML20215K565

From kanterella
Jump to navigation Jump to search
Deficiency Rept,Item 231 Re Use of Hylomar Thread Sealant in Stainless Steel Applications.Initially Reported on 860814. Item Not Reportable Per 10CFR50.55(e) Confirming 861014 Telcon
ML20215K565
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 10/14/1986
From: Chiangi N
CAROLINA POWER & LIGHT CO.
To: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
231, MQAH-86-170, NUDOCS 8610280214
Download: ML20215K565 (1)


Text

x w ,;

CP&L Carolina Power & Light Company HEEC - MQ Building cc I P. O. Box 327, New Hill, N. C. 27562 m l October 14, 1986 @

-t

]

E File: SH N-2/18 MQAH 86-170 2 Item 231 N a ,

CD I Dr. J. Nelson Grace 1 United States Nuclear Regulatory Commission Region II Suite 2900 101 Marietta Street, Northwest Atlanta, Georgia 30323 i

SHEARON HARRIS NUCLEAR POWER PLANT, UNIT NO. 1 DOCKET NO. 50-400 HYLOMAR THREAD SEALANT

Dear Dr. Grace:

This is to confirm the October 14, 1986 telephone conversation between Mr. K. V. Hate' (CP&L) and Mr. L. Mellen. Mr. L. Mellen was informed that the August 14, 1986, potentially reportable item, pertaining to use of the hylomar thread sealant in stainless steel applications, has been evaluated and is considered not to be reportable per the provisions of 10CFR50.55(e).

Thank you for pour assistance in this matter.

Yours very truly, n

N.

B-

. Ch an Quality A' ance/ Quality Control Harris Plant NJC:jp cc: Mr. G. F. Maxwell Mr. J. M. Taylor SW**#ci U$$1!

& sc>f