DEC 111986
Docket No.
50-219
License No. DRP-16
GPU Nuclear Corporation
ATTN: Mr. P. B. Fiedler
Vice President and Director
-Oyster Creek Nuclear Generating Station
P. O. Box 388
Forked River,.New Jersey 08731
Gentlemen:
Subject:
Inspection Report No. 50-219/86-34
This refers to the routine safety inspections by Messrs. W. Bateman,
J. Wechselberger, W. Baunack, P. Wen, and A. Finkel during the period of
October 6 through November 16, 1986 at the Oyster Creek Nuclear Generating
Station. The inspections consisted of document reviews, interviews and
observations of activities as documented in the enclosed inspection report.
The findings were discussed with you and other members of your staff at the
conclusion of the inspection.
Within the scope of this inspection, no violations were identified.
Your cooperation with us in these matters is appreciated.
Sincerely,
Original Sisucd By:
Allen R. Blough, Chief
Projects Branch No. 1
Division of Reactor Projects
Enclosure: NRC Region I Report No. 50-219/86-34
cc w/ encl:
BWR Licensing Manager
Licensing Manager, Oyster Creek
Public Document Room (PDR)
local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector
State of New Jersey
8612160451 861211
ADOCK 05000219
G
,
OFFICIAL RECORD COPY
IR OYC 86-34 - 0001.0.0
12/10/86 IEol ll t
C ,_
..
GPU Nuclear Corporation
2
bcc w/ encl:
Region I Docket Room (with concurrences)
Management Assistant, DRMA (w/o encis)
DRP Section Chief
DRS Director
bobsN #
D. Florek
-P. Wen
A. Finkel
kj
'pf
Ph
RI:DRP
R
-
an
C te
Blough
12// o /86
12//d/86
12//0/86
0FFICIAL RECORD COPY
IR OYC 86-34 - 0001.1.0
12/08/86