TABLE lA EFFLUENT AND WASTE DISPOSAL REPORT (1986)
GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES l
l UNIT l QTR l QTR l QTR l QTR l TOTAL l A.
FISSION & ACTIVATION GASES 1.
TOTAL RELEASE Ci 1.67E3 8.32E2 2.50E3 2.
AVERAGE RELEASE RATE FOR PERIOD pCi/Sec 2.09E2 1.06E2 B.
TOTAL 10 DINE-131 Ci 9.89E-4 6.93E-4 1.68E-3 2.
AVERAGE RELEASE RATE FOR PERIOD I-131 pCi/Sec 1.26E-4 8.82E-5 C.
PARTICULATES 1.
PARTICULATES W/ HALF-I LIVES > 8 DAYS Ci 1.90E-4 1.33E-4 3.23E-4l 2.
AVERAGE RELEASE RATE FOR PERIOD uC1/Sec 2.49E-5 1.67E-5 3.
GROSS ALPHA RADIOACTIVITY Ci 1.09E-6 7.81E-6 D.
TRITIUM 1.
TOTAL RELEASE C1 4.14E0 2.56E0 6.70E0 2.
AVERAGE RELEASE RATE FOR PERIOD pCi/Sec 5.27E-1 3.25E-1 E.
PERCENTACE OF TECHNICAL SPECIFICATION LIMITS 1.
NOBLE CAS RELEASE QTR QTR QTR QTR YEARLY GAMMA 2.94 1.68 3.80 BETA 1.41 0.80 1.82 2.
1-131, I-133, H-3 AND ALL RADIONUCLIDES IN PARTICULATE FORM WITH HALF-LIVES CREATER THAN 8 DAYS QTR QTR_
QTR QTR YEARLY l
HIGHEST ORGAN l
l.06 0.89 1.88 8612050380 861121 PDR ADOCK 05000409 R
pop
_y_
WP4.17
o TABLE IB - EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1986)
GASEOUS EFFLUENTS - ELEVATED RELEASE - (cont'd)
CONTINUOUS MODE l_NUCLIDESRELEASED l UNIT l QTR l QTR l QTR l QTR l TOTAL l 3.
PARTICULATES STRONTIUM-89 CI 5.23E-6 1.24E-6 6.47E-6 STRONTIUM-90 CI CESIUM-134 CI 7.90E-7 7.90E-7 CESIUM-137 CI 1.67E-5 7.21E-6 2.39E-5 BARIUM-LANTHANUM-140 CI 1.35E-4 4.23E-5 1.77E-4 CO-57 CI 1.53E-6 2.09E-7 1.74E-6 C0-58 CI 2.10E-6 6.97E-6 9.07E-6 CD-60 CI 1.62E-5 4.07E-5 5.69E-5 CE-144 CI 1.52E-6 1.52E-6 CE-141 CI 1.06E-6 1.06E-6 CR-51 CI MN-54 CI 5.41E-6 1.53E-5 2.07E-5 FE-59 CI 1.01E-5 4.82E-6 1.49E-5 ZN-65 CI 8.80E-7 2.96E-6 3.84E-6 ZR-95 CI NB-95 CI 2.50E-7 1.70E-6 1.95E-6 RU-RH-106 CI 6.20E-6 4.88E-6 1.llE-5 RU-103 CI 2.20E-7 2.27E-6 2.49E-6 CI CI CI CI CI WP4.17
TABLE 2A EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1986)
LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES f
l UNIT l QTR l QTR l QTR l QTR l TOTAL l A. FISSION AND ACTIVATION PRODUCTS
- 1. TOTAL RELEASE (NOT INCL.
TRITIUM, GASES, ALPHA)
Ci 2.63E0 1.32E0 3.95E0
- 2. AVERAGE DILUTED CONCEN-TRATION DURING PERIOD uCi/mi 2.96E-7 1.38E-7 B. TRITIUM
- 1. TOTAL RELEASE l
Ci 3.33E1 5.14E0 3.84E1
- 2. AVERAGE DILUTED CONCEN-TRATION DURING PERIOD UCi/mi 3.74E-6 6.29E-7 C. DISSOLVED AND ENTRAINED CASES I
- 1. TOTAL RELEASE Ci 1.42E-1 3.98E-2 1.82E-1
- 2. AVERAGE DILUTED CONCEN-TRATION DURING PERIOD UCi/ml 1.59E-8 3.64E-9 i
D. GROSS ALPHA RADIOACTIVITY
- 1. TOTAL RELEASE C1 1.15E-3 1.07E-3 2.25E-3 E. VOLUME OF WASTE RELEASED l
(PRIOR TO DILUTION)
Liters 9.42E5 9.92E5 1.93E6 r
F. VOLUME OF DILUTION WATER j
USED DURING PERIOD Liters 8.89E9 8.18E9 1.71E10 G.
PERCENTAGE OF TECHNICAL SPECIFICATION LIMITS FOR LIQUID RELEASES QTR QTR QTR QTR YEARLY HIGHEST ORGAN 29.76 24.42 27.10 WHOLE BODY 64.22 52.57 58.3 WP4.17
1 TABLE 2B EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT (1986)
LIQUID EFFLUENTS NUCLIDES RELEASED UNIT QUARTER QUARTER QUARTER OFARTER j
STRONTIUM-89 CI 1.98E-3 1.88E-3 I
STRONTIUM-90 CI 2.36E-3 7.93E-4 CESIUM-134 CI 1.00E-4 2.06E-4 CESIUM-137 CI 3.62E-2 3.79E-2 10 DINE-131 CI 2.32E-2 5.26E-3 COBALT-58 CI 9.03E-2 5.82E-2 COBALT-60 CI 8.27E-1 6.78E-1 IRON-59 CI 1.01E-1 6.30E-2 ZINC-65 CI 1.48E-2 1.26E-2 MANGANESE-54 CI 2.21E-1 1.87E-1 CHROMIUM-51 CI 6.88E-2 2.12E-2 ZIRCONIUM-NIOBIUM-95 CI 1.35E-2 7.88E-3 MOLYBDENUM-99 CI 2.51E-2 6.21E-3 TECHNETIUM-99M CI 6.05E-2 8.02E-3 BARIUM-LANTHANUM-140 CI 5.30E-2 8.08E-3 CERIUM-141 CI 4.29E-3 1.54E-3 CE-144 CI 4.58E-3 2.25E-3 CO-57 CI 1.07E-3 4.27E-4 I-133 CI 6.02E-2 9.40E-3
)
1-135 CI 3.35E-2 1.85E-3 NP-239 CI 3.32E-2 2.49E-3 I
RU-103 CI 1.42E-2 4.28E-3 RU-RH-105 CI 3.59E-2 5.86E-3 RU-RH-106 CI 4.74E-3 6.46E-4 SR-91 CI 1.97E-2 1.03E-3 i
i SR-92 CI 4.41E-3 3.06E-4 l
AG-110M CI 3.66E-3 7.72E-4 NB-97 CI 6.27E-3 1.78E-4 NA-24 CI 9.26E-4 4.00E-5 ZR-97 CI 1.19E-4 MN-56 CI 5.12E-5 I-132 CI 9.55E-4 W-187 CI 1.70E-2 i
Y-92 CI 9.llE-2 4
CE-143 CI 1.09E-3 CS-136 CI 4.54E-3 I
FE-55 CI 7.54E-1 1.98E-1
)
TOTAL FOR PERIOD ( ABOVE)
CI 2.63E0 1.12E0 1
1 j
XENON-133 CI 1.21E-2 2.23E-3 1
XENON-135 CI 3.03E-2 2.12E-3 XE-131M CI 3.74E-2 7.82E-3 XE-133M CI 9.77E-5 3.54E-5 XE-135M CI 7.89E-3 j
KR-85M CI 5.17E-5 9.51E-6 j
KR-87 CI 1.17E-5 CI
- l WP4.17
.