Qs CA&L Carolina Power & Light Company HARRIS NUCLEAR PROJECT P.O. Box 165 New Hill, NC 27562 MAY 2 81987 File Number: SHF/10-13510C 10CFR50.59 Letter Number: H0-870428 (0)
U.S. Nuclear Regulatory Commission ATTN: NRC Document Control Desk Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT UNIT 1 DOCKET NO. 50-400 LICENSE NO. NPF-63 QUARTERLY REPORT IN ACCORDANCE WITH 10CFR50.59 Centlemen:
In accordance with 10CFR50.59 and CP&L Letter (NLS-86-454) of commitment dated December 9, 1986, the following report is submitted for the first quarter of 1987. This report also covers changes made in 1986 following the submittal of FSAR Amendment No.
- 37. This report contains brief summaries of changes to procedures and plant modifications, which change the plant as it is described in the FSAR. There were no tests or experiments conducted during this interval, which are not described in the FSAR which require reporting in this report. Changes to FSAR Chapter 14 have been previously submitted by separate letters.
Very truly yours, R. A. Watson Vice President Harris Nuclear Project RAW:lmj Enclosure cc:
Dr. J. Nelson Crace (NRC - RII) g Mr. C. Maxwell (NRC - SIINPP) i 8706030028 870528 PDR ADOCK 05000400 l
R PDR MEM/IIO-8704280/PAGE 1/OS!
f a
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE:
PCR-000259, Auxiliary Feedwater System Venting Provision.
FUNCTIONAL
SUMMARY
- This plant modification added high point vents on discharge piping downstream of the Auxiliary Feedwater (AFW) Pumps. The addition of these vents will allow purging air or steam from the piping without the need for running the AFW pumps.
SAFETY
SUMMARY
- This modification was designed to ASME Section III and Seismic Class I requirements. The added valves fall within the existing safety analylsis. This modification does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
l MEM/HO-8704280/ PACE 3/0S1
t CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-000423, Residual Heat Removal / Safety Injection System Vent Valves.
FUNCTIONAL
SUMMARY
- This plant modification added system high point vents to facilitate normal plant operations. These additional vents will allow adequate surveillance testing, reduce maintenance time, eliminate system flush to refill and vent the system, and allow periodic testing for hydrogen migration.
SAFETY
SUMMARY
- This modification was designed to ASME Section III and Seismic Class I requirements. The additional valves fall within the existing safety analysis. The addition of the subject vent valves does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
MEM/HO-8704280/ PACE 4/OS1
f l
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-000470,- Boron Concentration Monitor Abandonment FUNCTIONAL
SUMMARY
- This plant modification deletes the Boron Concentration Monitor., The Boron Concentration Monitor has been valved out and abandoned in place.-
SAFETY
SUMMARY
- The Boron Concentration Monitor was designed for use as an advisory system and the deletion of this monitor has no safety impact.
It was not designed as a safeguards system or a control system. No credit was taken for this system in an accident analysis. As a general operating aid, it provided information as to when additional checks were. warranted rather than a basis for fundamental operating' decisions.
1 MEM/HO-8704280/PAGE 5/0S1
f a
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-000489, Emergency Service Water (ESW) Auxiliary Feedwater (AFW)
Crossover Legs FUNCTIONAL
SUMMARY
- This plant modification adds an orificed drain line with a loop seal to the ESW/AFW Crossover Piping. The spaces between the redundant valves separating the AFW suction and ESW system had previously been vented to prevent leakage from ESW to AFW. It was determined that on switch over to the ESW supply the resulting air _ bubble may damage the AFW pumps. The modification allowed the space to be filled with water and vented to a drain to accomodate any ESW leakage.
SAFETY
SUMMARY
- .This change is intended to increase the reliability of the AFW system. The installation of the loop seal prevents the creation of an air-binding malfunction. This change does not increase the probability or consequences of an analyzed accident, nor does it create a new or different type of accident. This change improves the reliability of the AFW System and therefore does not significantly reduce the margin of safety.
MEM/H0-8704280/PAGE 6/0S1
t ~
i-CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-000668,~ Auxiliary Feedwater Pump Vents FUNCTIONAL
SUMMARY
- This plant modification will install casing vent valves on the suction and discharge sides of the IA-SA and IB-SB Auxiliary Feedwater (AFW) pumps. Vents fitted with plugs already existed in the pump casings.
The addition of vent valves on the pump casing will enhance filling and venting of the AFW pumps and system.
SAFETY
SUMMARY
- Auxiliary Feedwater reliability and availability will not be decreased by the modification as described above. This modification does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
f i
V k
1 I
e-6 i
l MEM/HO-8704280/PAGE 7/OSI
t
's.
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-000785, Service Air Leakage Outside the Diesel Generator Building FUNCTIONAL
SUMMARY
- . This plant modification restores service air piping to bypass an underground air leak in the vicinity of the Diesel Generator (DC)
Building.
SAFETY
SUMMARY
- The service air system is not safety related and rerouting the servit: air piping in the vicinity of the DC Building does not impact any safety reisted equipment. The_ rerouting of this piping does not alter which equipment is being serviced with air in the vicinity.
l MEM/HO-8704280/ PACE 8/051
e s
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-001109, Electric Heating Coils, EHCl3 and EHC15 Modifications FUNCTIONAL
SUMMARY
- This plant modification involves the partial removal of HVAC heater elements to eliminate hot spots in low flow areas. The heater capacities as listed in the PSAR were reduced.
SAFETY
SUMMARY
These heating coils are located in the non-safety related normal supply system servicing the Fuel Handling Building spaces below the operating floor. This change affects only local HVAC balancing and heater output. The original design temperatures and flows are not affected. This change does not affect any accident analysis or procedures.
l HEM /HO-8704280/ PACE 9/0S1
s CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-001145, Auxiliary Feedwater (AFW) Check Valves Accessibility FUNCTIONAL
SUMMARY
- This plant modification deletes one of the double isolation drain valves in each line located in the RAB Steam Tunnel Elevation 261'.
Accessibility to AFW check _ valves for performance of inline maintenance was restricted as originally installed.
SAFETY
SUMMARY
- Auxiliary Feedwater reliability and availability will not be decreased by the modification described above. This modification does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
MEM/HO-8704280/ PACE 10/0S1
.r
/.
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR i
TITLE: PCR-001174, Mode 2 Start-Up Steam Generator Low Pressure Interlock l
FUNCTIONAL
SUMMARY
- The FSAR states that the Auxiliary Feedwater (AFW) System will be -used to adjust steam generator. water levels prior to an'd during plant start-up. This was necessary due to a Steam Generator Low Pressure interlock which prevented the use of the Condensate /Feedwater system to be used for this function. This change disables the interlock and allows the Condensate /Feedwater system instead of the AFW system to be used to adjust steam generator water levels prior to and during plant startup.
SAFETY
SUMMARY
- The Steam Generator low pressure interlock does not protect equipment important to safety during specified plant conditions. This modification does not increase the probability or consequences of analyzed accidents nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
s a
Y f
.II' e
Max /HO-8704280/ PACE 11/0S1 y
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: FCR-FP-1133, Fire Seal Requirements in Non-rated Floors l
FUNCTIONAL
SUMMARY
- This plant modification eliminates the requirements for fire seals in non-rated floors.
l SAFETY
SUMMARY
- The F.P. Safe Shutdown Analysis takes no credit for fire seals located in non-rated floors. Fire seals in non-rated floors are not included as part of the protection described in the SSA. Eliminating fire seals for which no credit was taken does not affect the probability or consequences of a fire analyzed in the SSA. The plant margin of safety is not significantly reduced.
r MEM/HO-8704280/ PACE 12/0S1
1 CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: FCR-SP-292, Condensate Vacuum Pump Effluent Treatment System (CVPET).
Fan Inlet and Discharge Valve Modification FUNCTIONAL
SUMMARY
- Due to orientation of CVPET Fan discharge valves moisture
-accumulates in the vertical duct adjacent to these valves. This plant modification relocates the outlet valve to a horizontal section downstream of the fan and deletes the inlet valve.
SAFETY
SUMMARY
- The CVPET is a non-nuclear safety ventilation cleanup system and is not part of the radwaste management system. The purpose of these valves was to prevent air from recirculating through the idle fan.
Eliminating the inlet valve and relocating the outlet valve does not affect this function and does not affect any accident analysis or the margin of safety.
2 MEM/HO-8704280/PAGE 13/0S1
~
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: FCR-HVAC-1730, Fume Hood Exhaust HEPA and Prefilters Deletion FUNCTIONAL'
SUMMARY
- This plant modification deletes HEPA and Prefilters from 7 of the 9 Fume Hoods Exhaust Systems in the Waste Processing Building Lab Area.
SAFETY
SUMMARY
- The HEPA and Prefilters being deleted are non-nuclear safety and do not interact with safety related equipment or systems. Deletion of this equipment does not affect plant accident analysis or the margin of safety.
I MEM/HO-8704280/PAGE 14/OSI
e
-o CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: FCR-AS-10702, Deletion of Elev.itor Number 3 FUNCTIONAL
SUMMARY
- This modification involves the deletion of Elevator #3 in the Turbine Building.
Elevator #3 was never constructed, the FCR merely revises the drawings to show this deletion.
SAFETY
SUMMARY
,: Deletion of Elevator #3 has no safety impact. This elevator is not considered in any accident analysis, it is' included because FSAR drawings need to be updated. Deletion of this elevator has no safety impact.
MEM/HO-8704280/PAGE 15/051
CHANCE TO FACILITY AS DESCRIBED IN THE FSAR TITLE:- FCR-C-6888, Masonry (Block) Walls in the Reactor Auxiliary Building -
Hot Shop Area FUNCTIONAL
SUMMARY
- This plant modification allows non-seismically designed masonry (block) walls to be erected in the Reactor Auxiliary Building (RAB) in the Hot Shop area on Elevation 236', between 'B' and 'H' Lines and 43' and 45' Lines. This area was previously designated for Unit 2.
Since the cancellation of Unit 2, the area is now utilized as a hot shop area. Prior to this change only seismically designed block walls were approved for use in the RAB.
SAFETY
SUMMARY
- There are no safety systems or safety equipment located in the subject Hot Shot area. The subject change in design of block walls will not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
I MEM/H0-8704280/ PACE 16/OSI i
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: FCR-SI-1011 Rev. 3, Change to Emergency Diesel Generator Output Meters Range FUNCTIONAL
SUMMARY
- FCR-SI-1011 resolved problems with the Emergency Diesel.
Generator varimeters reading downscale'and conflicts between design documents concerning correct _ polarity. Resolution of the problems included installation of new' scales on meters located on the Auxiliary Control Panel and the Main Control Board which differ in range than currently specified in FSAR Tables
'7.4.1-1 and 7.5.1-3 as indicated below. The following Diesel Generator Power indicators originally had a range of 0-8 MW and now have a range of 0-9.6 MW: EI-6957A2, EI-6957B2, EI-6957A1, EI-6957Bl. The following Diesel Generator Power indicator originally had a range of 0-6 MVAR and now has a range of 0-9.6 MVAR:'EI-6958A.
SAFETY
SUMMARY
- The above change is to the meter scale range only and does-not effect the actual output of the Diesel Generator. This change does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
MEM/HO-8704280/ PACE 17/0S1
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: FCR-I-3893 Rev. 1, Sequencer Test lA-SA FCR-I-3896 Rev. 1, Sequencer Test IB-SB FUNCTIONAL
SUMMARY
- This plant modification consists of relay and wiring changes to prevent relay racing between the sequencer test and the sequencer program relays when the test operation is interrupted. As previously designed, if an accident condition occurred or testing was interrupted while testing of the sequencer internal circuits was in progress, all the circuits would de-energize in 5 seconds. This could result in the test relay de-energizing before the program relay thus initiating an ESF actuation.
Operation of the test relay is now delayed such that the sequencer program relays de-energize first and then the testing relays.
SAFETY
SUMMARY
- The modification decreases any relay racing between sequencer test relays and program relays. The change does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
1 MEM/HO-8704280/PAGE 18/0S1
['
O-o CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: FCR-I-3995, Turbine Exhaust Hood Temperature Trip FUNCTIONAL
SUMMARY
- The Turbine originally included an automatic Turbine Trip in the event the exhaust hood temperature reached 250*F.
This plant modification disarms the automatic trip function. Turbine Exhaust Hood Temperature data is still available to the operator and if necessary a manual trip could be initiated for High Exhaust Hood Temperature.
SAFETY
SUMMARY
- The Turbine is non-safety related. This modification does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
MEM/HO-8704280/ PACE 19/0S1
..~
CHANCE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: FCR-M-2009, Deletion of Equipment Removal Crane FUNCTIONAL
SUMMARY
- The Equipment Removal Crane located outside the Containment Equipment Hatch has been deleted.
SAFETY
SUMMARY
- The crane is not safety related and is not included in any accident analysis. Removal of the equipment removal crane will not effect any safety related systems or accident analysis.
MEM/HO-8704280/ PACE 20/0S1
n o
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: Westinghouse Drawing (1766E37, Rev. 3) "Shearon Harris Unit 1 Core Loading Plan Cycle 1" and Revision 3 to the Unit 1 Core Component Loading Chart (PSAR Figure 4.2.2-13)
FUNCTIONAL
SUMMARY
- The axial location of the californium source within the primary source rod was changed. The californium source in the primary source rod has been repositioned 8 and 1/2 inches higher in order to meet the Westinghouse requirement that the primary source be located mid plane of the source range detector. This change results in a change to FSAR Figure 4.2.2-13 (i.e., the bottom spacer height is now 41.0 inches, instead of 32.5 inches).
SAFETY
SUMMARY
- The required minimum source range audible count rate is not changing. This change repositions the primary source in order to meet the requirement that it be located mid plane of the source range detector. As such, this change fulfills the original design requirements instead of revising them. The change does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
I i
MEM/HO-8704280/ PACE 21/OS1
s---
A--
_E-_
=o CHANGE TO FACILITY AS DESCRIBED IN THE FSAR I
TITLE: FCR-HVAC-1665, Emergency Service Water Intake Structure (ESWIS),
Electrical Equipment Room HVAC System AH-86 FUNCTIONAL
SUMMARY
- 'This plant modification changes the design of the HVAC I stem servicing the Electrical Equipment room in the ESWIS such that when the outside air temperature is less than 73*F, all air in this room is
-recirculated and no outside air is provided.
SAFETY
SUMMARY
- This plant modification will not increase the probability or j
consequences of an accident previously analyzed and does not create a new or j
different type of accident. This change will not increase the probability or i
consequences of failure of equipment important to safety. This change does not alter the ESWIS Electrical Equipment room maximum temperature listed in Tech. Specs and the FSAR.
4 i
4 l
i l
f I
E 5
1 MEM/HO-8704280/ PACE 22/0S1
O o
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: FCR-M-1973 and FCR-HVAC-1672, Electric Equipment Room Ventilation System - Diesel Generator Building FUNCTIONAL
SUMMARY
- This plant modification deletes the flow of service water to the cooling coils for the air handling unit (AH-85) which services the Electric Equipment Room in the Diesel Generator Building. As part of this change, the systems return air damper is now locked fully open and the outside air damper opens and closes as outside and room temperature change.
SAFETY
SUMMARY
- Calculations were performed to demonstrate that with service water isolated from AH-85 the ability to maintain temperature control in the Electrical Equipment Room is retained. This change does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
MEM/HO-8704280/ PACE 23/OS1 i
L
.g.
o CHANCE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-001040, Seal Drains for Heater Drain Pumps FUNCTIONAL
SUMMARY
- This plant modification pipes the Heater. Drain Pump mechanical seal drain / bleed off line to the pumps suction. As previously designed, the seal dealn/ bleed off line went to an open floor drain. In this configuration, with the pumps running, excessive steaming occurred presenting a personnel hazard and the potential of excessive moisture in motors.
SAFETY
SUMMARY
- The heater drain system is non-safety related. This change does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
MEM/HO-8704280/ PACE 24/0S1
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-000409, Secondary Waste Sample Tank / Waste Monitor Tanks Cross-Connection FUNCTIONAL
SUMMARY
- This plant modification provides a cross connection between the Secondary Waste Sample (SWS) Tank and the Waste Monitor Tanks.
This modification provides additional tank capacity and operational flexibility for waste surges and contaminated steam generator wet lay-up water.
SAFETY
SUMMARY
- This modification will not affect the present analysis of the Liquid Waste Processing System. The change does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
MEM/H0-8704280/ PACE 25/OSI
.o CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-000939, Digital Electric Hydraulic (DEH) System Load Rejection Capability FUNCTIONAL
SUMMARY
- This plant modification enables the DEH system to successfully respond to a large generator load rejection. The previous configuration of the DEH system computer and fluid components were such that it was not capable of handling a large generator load rejection. As part of Westinghouse recommendations, the overspeed protection control setpoint was increased from 103% as described in FSAR Section 10.2.2.5 to 105% of the rated turbine speed.
SAFETY
SUMMARY
Increasing the overspeed protection control setpoint is necessary to enable the system to respond to a large generator load rejection. This change does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. This does not impact on the turbine mechanical or electrical trip for overspeed which is 110% of rated speed. Thus no unreviewed safety question exists.
MEM/110-8704280/ PACE 26/OSI
O O
CHANCE TO FACILITY AS DESCRIBED IN THE FSAR TITLE:
PCR-000310, Vendor Mobile Solidification System Hook-Up FUNCTIONAL
SUMMARY
- The previous design of the Radwaste Solidification System did not provide the capability to hook up a vendor's mobile solidification system as a backup to the installed Stock Solidificatien System. This modification allows a vendor to hook up a mobile unit.to the plants Solidification Systems Pretreatment Tank, Spent Resin Storage Tank, and Filter Particulate Concentrates Tank.
SAFETY
SUMMARY
- The consequences of a spill of the Liquid' Waste Processing System will not increase since the contents will be contained within the Waste Processing Building (WPB). The modification will not increase the inventories or sources contained in the WPB which have already been analyzed.
MEM/HO-8704280/ PACE 27/051
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE PCR-000248, Addition of Nitrogen Sparger System To The Reactor Makeup Water Storage Tank (RMWST)
FUNCTIONAL'
SUMMARY
This plant modification installs a nitrogen sparger in the RMWST in order to effectively strip dissolved oxygen from the contents of the tank. The supply of nitrogen to this sparger is limited by a one quarter inch pressure regulating valve and is normally discharged through four three inch non-nuclear safety vent valves. A six inch ASME Sect. III, Class 3 relief valve has been placed on the overflow of the tank for additional protection.
SAFETY
SUMMARY
- The RMWST is not required for safe shutdown of the plant.
This modification does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
MEM/HO-8704280/ PACE 28/OS1
CHANCE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: PCR-000422, Feedwater Heater Vents and Drains FUNCTIONAL
SUMMARY
- This is not a modification to the plant but is a correction to design documents.
FSAR Figure 10.1.0-5 describes the valves (1HD-157 and 1HD-457) on heater drain lines which come off the discharge side of the Heater Drain Pumps (1A & IB) going to the Sampling System as normally closed. This change will reflect the correct operation of the system on the design drawings and FSAR Figure by showing these valves as normally open.
SAFETY
SUMMARY
- The Heater Drain System is a non-safety system and does not affeet safety related equipment. This change does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
4 E
r MEM/HO-8704280/ PACE 29/051
CHANCE TO FACILITY AS DESCRIBED IN THE FSAR TITLE Containment Cooling System Normal Operation FUNCTIONAL
SUMMARY
- This plant modification revises the normal operation of the containment safety fan coolers dampers. The nozzle dampers are interlocked so that under normal operating conditions the dampers are positioned depending on the containment average temperature.
If the containment average temperature is below or equal to ll8'F, the nozzle dampers are closed. If the containment average temperature is above 118'F, the nozzle dampers for safety fan coolers AH-3 and AH-4 are open and the nozzle dampers for safety fan coolers AH-2 and AH-1 are closed.
SAFETY
SUMMARY
- This plant modification affects operation of these dampers during normal operations only and do not affect safety fan cooler operations during an accident. This change is intended to enhance temperature control in the containment during normal operation. Operations during accident conditions are not affected. This plant modification does not increase the probability or consequences of an accident or malfunction of equipment important to safety.
It does not create a new or different type of accident or significantly reduce the margin of safety.
h MEM/HO-8704280/ PACE 30/0S1
~.
o o
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: Radiation Monitoring
. FUNCTIONAL
SUMMARY
- The design of the process radiation monitors for the Auxiliary Steam (AS) Condensate return was supplement ed to provide automatic termination of releases to the condenser or the auxiliary boiler and automatic isolation of the tank vents when radiation is detected in the AS condensate.
SAFETY
SUMMARY
- The plant design uses an auxiliary steam system to provide process steam for radioactive waste evaporators. The steam used in these evaporators is condensed and collected for reuse.
In the'unlikely event that the steam side of the evaporator becomes contaminated due to leaks within the evaporator, the radiation monitors will provide isolation of the transfer of this water to a noncontaminated system such as the auxiliary boiler. These monitors were previously described in the FSAR, but the automatic isolation function was not. The addition of the isolation function provides a protection against the undetected release of radioactive material from the plant.
MEM/HO-8704280/ PACE 31/0S1
e o
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE ' Revision to Position on Regulatory Guide 1.38 FUNCTIONAL
SUMMARY
- The PSAR li ts exceptions to ANSI 45.2.2 as endorsed by Reg. Guide 1.38.
This Reg. Guide deals with QA requirements for the storage of safety-related items prior to installation in the plant. The FSAR provides exceptions and clarifications with regard to this Reg. Guide. These items were supplemented with an additional exception to include the latitude to evaluate storage recommendations (including maintenance required during storage) made by the vendor in view of the specific storage condition provided at the plant.
If after evaluation, it is concluded that equivalent protection is provided, the vendors specific recommendation may be modified.
SAFETY
SUMMARY
- The purpose of the regulatory recommendations is to assure that storage conditions do not degrade safety-related equipment. The change assures that any change to the vendors recommendations are documented and provide an equivalent level of protection during storage.
i i
a MEM/HO-8704280/ PACE 32/0S1
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLEt Area Radiation Monitor RM-1WR-3642A FUNCTIONAL
SUMMARY
- Area - Radiation Monitor RM-1WR-3642A listed in FSAR Table 12.3.4.-1 has been deleted from the design. The location being noted for this monitor is no longer used for contaminated equipment storage and so the monitor was deleted.
SAFETY
SUMMARY
- The monitor was not safety related and did not perform any safety related functions. The removal of the monitor does not result in a unreviewed safety question.
I I
4 i
1 4
t i
MEM/HO-8704280/ PACE 33/0S1
CHANGE TO FACILITY AS DESCRIBED IN THE FSAR TITLE: FCR-M-2035, Condensate & Chemical-Feed System Modifications FUNCTIONAL
SUMMARY
- This plant modification changed piping configurations to allow removal of excess condensate from the condenser hotwell by both the condensate booster pump and the condensate pump discharge to the Condensate-Storage Tank (CST). As previously designed, only the condensate pump discharge was utilized for this function.
SAFETY
SUMMARY
- This modification allows improved chemistry control. This modification deals with the non-safety portion of the condensate and chamical feed system. This modification does not change the elevation of any penetrations in the CST. The change does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR.
Thus no unreviewed safety question exists.
MEM/H0-8704280/PAGE 34/OSI
o CHANGE TO PROCEDURE AS DESCRIBED IN THE FSAR TITLE: OP-125, Rev. 1, Advance Change 1/3, Post Accident Hydrogen System Approval Date:
February 12, 1987 FUNCTIONAL
SUMMARY
- OP-125 utilizes containment isolation valves for the hydrogen analyzers for continuous sampling, therefore, causing the valves to be normally open. FSAR Table 6.2.4-1 indicated that these valves were normally closed instead of normally open.
SAFETY
SUMMARY
- By operating the system continuously, the system is available for monitoring minimizing time needed to start the system. This procedure change does not increase the probability or consequences of analyzed accidents, nor introduce a different type of accident or equipment malfunction than already evaluated in the FSAR. Thus no unreviewed safety question exists.
MEM/HO-8704280/ PACE 35/0S1
o a o
CHANGE TO PROCEDURE AS DESCRIBED IN THE FSAR TITLE:
Semi-Fixed Foam System FUNCTIONAL
SUMMARY
- This procedural change revises Fire Protection procedures for the semi-fixed foam system for the auxiliary boiler fuel oli storage tanks located in the yard. After the foam solution is depleted, water will be manually shut off to prevent diluting the foam blanket instead of the previous Fire Protection practice of allowing the water to centinue to flow.
SAFETY
SUMMARY
- This procedural change has no safety impact since this foam system is not used to protect safety related systems or areas. The procedural change actually improves the fire protection provided to the auxiliary boiler fuel oil storage tanks and as such does not decrease the margin of safety.
This change does not affect the Fire Protection Safe Shutdown Analysis.
HEH/HO-8704280/ PACE 36/OS1
o a e
CHANGE TO PROCEDURE AS DESCRIBED IN THE FSAR TITLE: Control of Safety Related Monitors from the Non-Safety RM-Il Consoles FUNCTIONAL
SUMMARY
- This procedure revision allows control of data base changes for safety related monitors from the non-safety related RM-ll Consoles.
Previously, control of data base changes for safety related monitors was only possible from the safety related RM-23 monitors in the Control Room. The RM-ll control capability will allow Radiation Control personnel to respond expeditiously and avoid major system problems.
SAFETY
SUMMARY
- This procedure revision is an administrative change in the control of radiation monitoring equipment.
It does not increase the probability or consequences of an analyzed accident, nor does it create the possibility of a new of different type of accident. This revision does not change the operation of any plant system.
It only changes the location of control of portions of the Radiation Monitoring System that were previously controlled from the RM-23.
MEM/HO-8104280/ PACE 37/0S1
m--
5 o c. o CHANGE TO PROCEDURE AS DESCRIBED IN THE FSAR TITLE: Main Generator Purging Procedure FUNCTIONAL
SUMMARY
- The procedure for purging the Main Generator includes a major step which is not described in the FSAR. The FSAR describes the purging of the hydrogen with carbon dioxide.
Subsequent to this, the carbon dioxide l
is purged with air. When this is completed, the generator is opened for access.
SAFETY
SUMMARY
This change does not involve safety-related equipment or systems. The purpose of the FSAR change is to describe in more detail the procedure.
MEM/HO-8704280/ PACE 38/0S1