LA Xicket File JAN 191979 QAB Projects QAB Chron. File NRR Reading File DJSkovholt, DPM DLynch, DPM Docket No. 50-397 DVassallo, DPM DBeckham, QAB RMcDermott, QAB HEMORANDUM FOR:

S. A. Varga, Chief. Light Water Reactors Branch No. 4, Division of Project Management FROM:

Walter P. Haass, Chief, Quality Assurance Branch.

Division of Project Management

SUBJECT:

WASHINGTON NUCLEAR PROJECT NO. 2, FIRST ROUND QUESTIONS FOR O! APTER 14. INITIAL TEST PROGRAM Applicant: Washington Public Power Service Systen Licensing Stage: OL Responsible Branch: LWR #4 Project Manager:

D. Lynch Requested Completion Date: January 8,1979 Review Status: First Round Questions Complete through Amendment 1 The Quality Assurance Branch has reviewed FSAR Chapter 14 describing the initial test program submitted in support of the Operating License Application for Washington Nuclee Project No. 2.

Our Request for Additional Infonnation is enclosed.

Original signed by Walter P. Haass Walter P. Haass, Chief Quality Assurance Branch Division of Project Management

Enclosure:

Request for Additional Information

/ 7 9 013 I o a fg/)

i y;hj DBeckHam{.]_

ABg..

..DP.1kQA

....DP

.D/gd 3_ _ _,.

  • "'a*

g)

..,RMc nott

_G.P

. /l[. 9_

3//f/Z9._

_.1/18/7.9_

l

..n mc ronu m &m mcw om b,.........,..=...........-..a

REQUEST FOR ADDITIONAL It;FORF ION WASHINGT0:1 fiUCLEAR PROJECT T40. 2 423.11 Your replies to questions 423.2, 423.6. and 423.7 do not clearly identify the level uf participaticn cf GE. Burns 5 Roe, and *.7iG3 personnel, ottier than menbers of the Test Working Group and Plant Operating Corr.mittee, in the prepara-tion, conduct, and review of preoperational and startup tests and do not provide for qualification of all personnel involved in preparation, conduct or review of tests.

Your response should clearly establish minimum qualification requirements for supervisory and review positions. Our position in this respect is that, in general, the minimum qualification requirements listed below are appropriate for typical organizations.

The minimum qualifications of individuals that direct or supervise the conduct of individual preoperational tests are (at the time that the individual is assigned to the task):

1.

A bachelor's degree in engineering or the physical sciences or the equivalent and one year of applicable power plant experience.

Included in the one year of experience should be at least three months of indoc-trination/ training in nuclear power plant systems and component operation of a nuclear power plant that is substantially similar in design to the type at which the individual will perfonn the function or, 2.

A high school diploma or the equivalent and four years of power plant experience. Credit for up to two years of this four year experience may be given for related technical training on a one-for-one time basis.

Included in the four years of experience should be at least three months of indoctrination / training in nuclear power plant systems and component operation of a nuclear power plant that is substantially similar in design to the type at which the individual will be employed.

Minimum qualifications of individuals that direct or supervise the conduct of individual startup tests are (at the time of assignment to the task):

1.

A bachelor's degree in engineering or the abysical sciences or the equivalent and two years of applica)le power plant experience of which at least one year shall be applicable nuclear power plant experience or, 2.

A high school diploma or the equivalent and five years of applicable power plant experience of which at least two years shall be y:plicable nuclear power plant experience.

Credit for up.c.so years of non-nuclear execrienco may be given for r ;ted technical training on a one-for-one time basis.

Minimu~ qualifications of individu !: assigrsd to groups responsible for re/iew and approval of crwuctional and startup test procedures and/or revi::a and approval of test results are (at tne tire tne activity is teing performed.)

1.

Eight years of applicable power plant experience with a minimum of two years of applicable nuclear power plant experience. A maximum of four years of the non-nuclear experience may be fulfilled by satisfactory completion of academic training at the college level.

423.12 Several sections including 14.2.4.4,14.2.5.2, and 14.2.6.1 reference the WPPSS Test and Startup Program Manual. To allow review of the material, the appropriate inforraation should be incorporated into the FSAR.

423.13 Describe the approximate numbers by job position and approximate schedule, relative to fuel loading, for providing test personnel.

423.14 In reply to our question 423.4, you modified Section 14.2.4.1.5 to address significant modifications or repairs to safety-related systems.

Define significant modifications and repairs and designate the group or individuals authorized to determine the significance of a modification or repair and to detemine retest requirements.

Also, specify how modifications and repairs that are not considered significant are to be controlled.

423.15 Revise Section 14.2.11 to ensure that test procedures will be available not less than 60 days prior to fuel loading.

423.16 Section 14.2.7 addresses conformance of test programs with Regulatory Guides.

This section should also address conformance with Regulatory Guides 1. 52, 1. 56, 1. 68.1. 1. 68. 2, 1.00, and 1.108. Also, modify the appropriate test descriptions to reflect the information in the Regulatory Guides.

423.17 Section 14.2.10.1.4, Master Startup Checklist, refers to preoperational testing listed in Table 14.2-4.

Table 14.2-4 is a list of startup tests. Correct the reference, k

423.18 Several pr'eoperational test prereouisites include the requirener,r. that support systems must have readiness v e r i f i ca *.i ln.

Previde a descrittien of rcadines:

vtrificat:cr. c.r.d s;,ucify unich ir.dividuaia or grons are authorized to make this determination.

423.19 Our review of your preoperational test phase disclosed that several systens and design features may not be scheduled to be praoperationally tested. The staff's evaluation of your preoperational test program was based on a comparison of your proposed test program with the structures, systems, components, and design features incluued in your facility design that:

1.

Will be relied upon for safe shutdown and cooldown of the reactor under normal plant conditions; 2.

Will be relied upon for safe shutdown and cooldown of the reactor under faulted, upset, or emergency conditions; 3.

Will be relied upon for establishing confomance with safety limits or limiting conditions for operation that will be included in the facility's technical specifications; 4.

Are classified as engineered safety features or will be relied upon to support or assure the operation of engineered safety features within design limits; 5.

Are assumed to function or for which credit is taken in the accident analysis for the facility; and 6.

Will be utilized to process, store, control, or limit the release of radioactivity.

The description of your preoperational test phase should be expanded or modified to address your plans relative to preoperational testing of the following:

1.

Logic, controls, valves, and components used in the condensate and feedwater heating systems.

2.

Auto Depressurization Valves, including demonstrations of cpercility using all siternate pne matic su; plies and demonstration of operability of oneumatic air supply systc;ns (reference Regulatory Guide 1.60),

I 4

~

3.

ATWS logic, controls, and final control elements.

4.

Let.k tightness of Control Rocm.

5.

Diesel Generator Air Starting System.

6.

" Keep-full" systens for HPCS, LPCS, and RHR pumps.

7.

Automatic transfer of suction from the CST to the suppression pool for the HPCS System.

8.

Temperature control of the Condensate Storage Tank.

9.

Manual isolation capability between the main condenser and the off-gas system.

10. Manual operations (local-manual) of all valves or dampers (that are provided with manual operators) for systems classified as engineered safety features. Your response should indicate whether this will be done as a part of each individual preoperational test, as a test pre-requisite, or as a construction acceptance test.
11. Timing tests for Recirculation System flow control valves.
12. Leak tightness tests for ECCS Systems.
13. Test firing of squib explosive devices ir, the TIP System and SLC System.
14. Response time testing of Engineered Safety Features including initiating logic.
15. ADS logic and power supplies including tests for redundancy, i
16. Heating. Air Conditioning and Ventilating Systems in the following areas: Main Control Room / Cable Spreading Room / Critical Switchgear Area, Emergency Diesel Generator Butiding. Diesel-Generator Cable Area Corridor, Radwaste Building, Reactor Building Emergency Cooling and Critical Electrical Equipment Area Cooling System.

17.

Standby Gas Treatment System.

18. MSIV Leakage Control System.
19. Oriented Spray Cooling System, t

423.20 He could not conclude from our review of the preoperationil test phase and the test abstracts provided in Table 14.2 that compre-hensive testing is scheduled for several of the described tests.

Th6refore, clarify or expand the description of tne preoperational test phase to address the following:

1.

Modify the individual AC and DC distribution system test descriptions or provide an integrated test description to verify pro er load group assignments.

(ReferenceRegulatory Guide 1.41.

2.

State your plans to verify that DC loads are in accordance with battery sizing assumptions and to verify the supplied loads remain operable at the minimum battery tenninal voltage equivalent to the initial and periodic load discharge tests.

Modify the 250 VDC,125 VDC, and 24 VDC system test descrip-tions to include this testing and provide acceptance criteria for the tests.

3.

State how operability of emergency loads using offsite power will be demonstrated during AC and DC system tests.

4.

Modify the Primary Containment Leak Rate test description to address the progression of test pressures and the method of closure of the containment isolation valves. Also, clarify whether local type B&C leak tests will be conducted as a part of construction testing or preoperational testing.

5.

Identify testing that will be accomplished to verify dry,vell floor bypass leakage and provide quantitative acceptance criteria.

6.

State your plans for testing the Primary Containment Isolation System, including response times of the containment isolation valves.

7.

State your plans for assuring that the effects of inter-between measured (e.g., snubbers pulse dampers) located facing hardware variables and the input to the sensors for the Reactor Protection System do not compromise the channel response time requirements. Modify the Reactor.

Protection System tert description and provide acceptance criteria that reflect the effect of these interactions.

8.

ffodify the Reacter Recirculation System and Control test description to c9monstrate correct operation of Recir-culation Flow Control Valve rate 1 5fters on flew controllers and demonstrate that indivicual control valve stroke rates do not exceed safety analysis assumptions. Provide quantitative acceptance criteria for the above.

r-i

.g.

423.21 Our review of your proposed startup testin? phase disclosed that some tests may not fully conform to regulatory positions described l

in Regulatory Guide 1.62.

Describe your plans relative to positions C.2.f and 1, 0.2.a (for ycur high pressure core spray system),

0.2.k (operation of a bypass valve), D.2.0, D.2.s (trip of two recirc pumps at 1005), and D.2.v of Appendix A.

423.22 Clarify the information in Section 14.2 to specifically identify each startup test listed in Table 14.2 that is not considered

" essential" to demonstrate the operability of structures, systems, and components that meet any of the criteria listed below, a.

Those that will be used for safe shutdown and cooldown of the reactor under normal plant conditions and fo'r main-taining the reac+or is a safe condition for an extended shutdown period; < r b.

Those that will be used for safe shutdown and cooldown of the reactor urder transient (infrequent or moderately l

frequent events) conditions and postulated accident conditions and for maintaining the reactor in a safe condition for an extended shutdown period following such conditions; or c.

Those that will be used for establishing ccaformance with safety limits or limiting conditions for operation that i

will be included in the facility technical specifications; or d.

Those that are classified as engineered safety features or will be used to support or ensure the operations of engineered safety features within desgin limits; or i

e.

Those that are assumed to function or for which credit is taken in the accident analysis for the facility, as described in the FSAR; or l

f.

Those that will be used to process, store, control, or i

limit the release of radioactive m3terials.

423.23 The status or mode of operations of plant control systems (automatic or manual) should be specified for all transient tests. Acceptance i

criteria relating to the performance of control systems should also be provided.

7 423.24 Our review of the test abstracts provided in your FSAR dis' closed that they are not sufficiently descriptive to conclude that comprehensive testing is planns:! or that satisfactory test acceptance criteria have been c:tablished. The individual test abstracts should be modified as indicated below:

1.

Provide technical justification for the Average Power Range lionitor Calibration Test level 2 acceptance criterion of f 7~ of rated power.

2.

Modify the test abstract for the Reactor Core Isolation Cooling System to provide for five cold quick starts of the system.

S Also, pecify' system conditions for cold quick s ta rt.

the Level 1 acceptance criteria refer to operating restriction on Figure 14.2-3 if the criteria are not met. Figure 14.2-3 does not indicate this restriction.

Provide adequate restrictions on operation if Level I criteria are not met.

3.

Expand the description of controls to ensure TIP reproducib'ility in the Core Power Distribution test for both random noise and geometric components. Also, provide assurance that the process computer properly calculates core power distribution for both symmetric and non-symmetric rod patterns. Provide technical justification for the Level II acceptance criteria.

4.

The description of the test methods in the Selected Process Temperatures Test should be expanded. The acceptance criteria should be made consistent with the stated test purpose.

5.

Modify or clarify the acceptance criteria for the System Expansion test to provide assurance that design stress levels or fatigue limits will not be exceeded.

6.

In the Core Power-Void Wade Test description specify the mode of control (auto or manual) of each of the principal control systems at each test condition. Provide technical justification or the bases for the Level 2 acceptance criterion to assure that if the acceptance criterion is just satisfied, that stable performance can be expected throughout core life.

7.

In the Pressure Regulator Startup Test specify the mode of control (auto or mnual) of each of the other princical control systems at each test condition. Provice technical justification or the bara: for the Level 2 acceptance criterion (paragraph 1) to assure that if the acceptance criterion is just satisfied, that stable performance can be expected throughout core life.

t

-g.

8.

Modify the Feedwater System Startup Test to specify th'e mode of control (auto or manual) of each of the other principal control systems at each test condition for the feedwater control setpoint changes.

Provide technical justification or the bases for the Level 2 acceptance criterion (paragraph 1) to assure that if the acceptance criterion is just satisfied, that stable performance can be expected throughout core life. Also, the test description should be modified to include a feedwater heater trip and to specifically identify:

(1) the type of trip to be initiated; (2) the feedwater heater (s) involved; and, (3) a discussion of how the planned trip relates to the worst case limiting ' event for your design that could result from a single equipment failure or operator error.

Acceptance criteria for this later transient should be modified to:

(1) identify the parameters or variables to be monitored; (2) provide assurance that the transient results will be compared with predicted results for the actual test case; and (3) provide quantitative acceptance criteria and their bases for the required degree of convergence of actual test results with predicted results for the monitored variables and parameters.

9.

Modify the description of the Turbine Valve Surveillance Test to ensure that the rate of valve stroking and timing of the close-open sequence is consistent with the conditions which will be experienced during surveillance tests.

10.

In the MSIV Tests modify the acceptance criteria for full MSIV closure at 100* power to:

(1) identify the parameters and variables that will be monitored; (2) provide assurance that the transient results will be compared with predicted results for the actual test case; and (3) provide quantita-tive acceptance criteria and their bases for the required degree of convergence of actual test results with predicted results forthe moni'tored variables and parameters. Also provide clear acceptance criteria for relief valves and RCIC performance during this transient. Also provide acceptance criteria for minimum values of individual valve closure times,

11. Modify the Turbine Trip and Generator Load Rejection Tests to (1) specify that both a turbine trip and a generator load rejection will be conducted from approximately full power; (2) correct the level 1 acceptance cr't~ia to be consistent with your design; (3) identify the variables or parameters
be r:onitored for eacn trip: N) provi:f. :ssurance that test results will be compared with predicted results for the actual tests to be run (for each trip), (5) provide q u ntit:tive acceptance criteria 'nd their bases for the reyf rM degree cf convergence of actual test results with predicted resuit: for the conitored variaoles and parameters

l l

for each trip; and (6) provide acceptance criteria for'

[

crid stability, voltage and frequency fellouing generator load rejection trips.

12. Modify the Recirculation Flow Control Startup Test cbstract i

to specify the mode of control (auto or manual) of each of the other principal control systems at each test condition where system stability checks will be conducted. Provide i

technical justification or bases to assure that if Level 2 l

acceptance criteria are just satisfied, that stable performance can be expected throughout core life.

13. Modify the Recircula'tior System Startup Test to define the i

types of trips, including two pump trips, to be conducted at each test condition and the manner by which the pumps will be tripped. Also modify the test description and provide acceptance criteria for flow coastdown and for ApRM flow biased rod block and scram transient setpoints following the double recire pump trip. Also provide stability criteria for plant performance following the trips.

14.

Modify the Loss of Turbine-Generator and Offsite Power Test abstract to:

J1 for the test including) describe the initial plant conditions the lineup of the plant's electrical l

system; (2) describe the type of trip to be conducted; l

(3) identify the variables, parameters and plant equipment to be monitored; (4) provide assurance that test results will be compared with predicted results for the actual test case; (5) provide quantitative acceptance criteria and their bases for the required degree of convergence of actual I

test results with predicted results for the monitored l

variables and parameters; and (6) provide functional acceptance criteria for plant equipment that should function during or following the test.

15.

The Reactor Water Cleanup System Test states that it will be run in three modes as described in the System Process l

Diagram. The System Process Diagrams (Figures 5.4-17 a.

i b, e and 5.4-18) do not define the three modes. Modify the test description and Level 2 acceptance criteria to correspond to the information presented in Chapter 5.

16.

The Residual Feat Removal System Test ac:eptanco criteria are based on flow rates and tem;,eratures in the process diagrams.

The RHR sy!!cm proc n: diagrc s do not c a tain this information. "odify the ac:eptance criteria to include the necessary information.

i t.

~

39 423.25 Chapter 5, Section 5.2.2.4.1 (page 5.2-12) of the FSAR specifies that the pre:perational and startup testing cf the rafety relief valves will include monitoring of the discharge line movement.

Modify the startup test description to reflect this commitment.

423.26 Chapter 5 Section 5.2.5.5.5 of the FSAR specifies that alarm points for the Leak Detection System will be detemined analytically or based on measurements of appropriate parameters made during startup or preoperational tests. Modify the test description to identify these parameters and the methods of determining the alarm points.

42327 Chapter 6, Section 6.3.2.2.3 (page 6.3-15) of the FSAR states that during preoperational testing of the Low Pressure Core Spray System, the discharge flow orifice will be sized to limit system flow to acceptable values as described in the LPCS process diagram.

Modify the test description to reflect this commitment.

423.28 Provide a preoperational test description for the various mode:;

and systems of the Fire Protection System.

423.29 Provide a schedule relative to fuel loading that specifies the scheduled time for performing low power and power ascension testing.

e