Div of Compliance Rept 50-275/69-01 on 690207.Major Areas Inspected:Tentative Const Schedule,Licensee Organization Responsible for Const & Info Re Vendors of Class I Equipment
ML20212N735
Person / Time
Site: Diablo Canyon 
Issue date: 03/03/1969
From: Andrea Johnson, Spencer G
US ATOMIC ENERGY COMMISSION (AEC)
To:
Shared Package
ML20212N718 List:
References
FOIA-86-585 50-275-69-01, 50-275-69-1, NUDOCS 8608290134
Download: ML20212N735 (5)


Text

.

o o

-V

(.

lr

(

s, p\\

U. S. ATOMIC ENERGY COMMISSION DIVISION OF COMPLIANCE i

REGION V Report of Inspection CO Report No. 50-275/69-1 i

O

"~'

Licensee:

Pacific Gas & Electric Company

^

Construction Permit No. CPPR-39 Category A Date of Inspection:

February 7, 1969 i

Date of Previous Inspection:

May 23, 1963 Inspected by:

/

/6dwr/

f/

~

.A. D. Johnson Reacto[ Inspector eC, 3!d j,

Reviewed by:

~ G. S. Spencer in t n.c-2 v

,. -(,-

Senior Reactor Inspector Proprietary Information:

None

  • %yM SCOPE t

Type of Facility:

Pressurized Water Reactor I

Power Level:

3250 Mwe Location:

Diablo Canyon near San Luis Obispo, j

California Type of Inspection:

Routine-Announced

'. s" Accompanying Personnel:

J. L. Crews, Reactor Inspector Scope of Inspection:

The visit was made to the licensee's main of fices in San Francisco, California to (1) review the tentative schedule of construction, (2) review the licensee's organization responsible for the construction of the Diablo Canyon nuclear power unit, and (3) obtain information relative to vendors of the Class I components.

8608'290134 860826 e)l(

PDR FOIA SHOLLY86-585 PDR i

r c

y%

(

(

SUMMARY

The current schedule of construction for the licensee's nuclear power station located at Diablo Canyon near San Luis Obispo, California calls for the start of construction of the containment building to begin during June,1969. To date, construction activities at the site have been limited to site preparation efforts, e.g.; earth excavating and

.y filling, installing utilities, and constructing an access road.

The licensee confirmed that the organization res'ponsible for the construction of the nuclear station was as shown in the application for a construction permit to build the second nuclear power unit at the same site.

(Diablo Canyon Unit No. 2)

Table No.1 of the report provides a' listing of vendors supplying the Class I components to be used in the construction of the reactor facility. Most of the vendors, accordin;; to the licensee, are common for all "four loop" Westinghouse pressurized water reactor systems.

C t

DETAILS A.

Persons Contacted D. W. Kelley

- Project Engineer - Chief Mechanical Engineer J. L. Schuyler - Senior Mechanical Engineer W. J. Lindblad - Design Engineer

.ip%%

B.

Project Administration 1.

Pacific Gas & Electric Co., PG&E Mr. Kelley provided the inspectors with a diagram of PC&E's organization concerned with constructing the Diablo Canyon

~

Nuclear Power Station. The structure of the organization as shown in Figure I, attached, conforms to the description provided in the licensee's application for the construction of Nuclear Unit No. 2 at the Diablo Canyon site which is also applicable to Unit No. 1.

According to the provided informat. ion, the currently assigned responsible individuals include:

i John F. Bonner

- Senior Vice President C. H. Sedam

- Vice President, General Construction p

J. D. Worthington - Vice President, Engineering l

D. V. Kelley

- Project Engineer, Chief, Mechanical Engineering B. W. Shackelford - Chief, Civil Engineering T. A. Bettersworth - Chief, Electrical Distribution Engineering

c

(

a 3

W. R. Johnson - Chief, Electrical Engineering J. J. McCann

- Chief, Engineering Services R. F. Cayot

- Engineering Research Specialist W. R. Forbes

- Equipment Inspector M. H. Chandler - Manager - Station Construction R. S. Bain

- Construction Superintendent

@h J. W. Woodward - Assistant Construction Supt. for Civil Structures W.

Hersey

- Project Superintendent A.

ekman

- Field Engineer, Mechanical /

/

/

A g. Wright

- Field Engineer, Electrical f,./p S. Friedrich

- Field Engineer, Civil D. Brand

- Startup Engineer m

)

i 2.

Vendors Mr. Kell provided the current list of vendors shown in Table I.

l Tnese y dors are concerned with supplying class I components for the constructfon of the nuclear power unit.

C.

Status of C'onstruction "'

The status of construction was discussed with Messrs. Kelley, Schuyler and Lindblad. From the discussions, it was apparent that construction activities have been limited to date to site preparation efforts including:

~

1.

Excavating for containment building 2.

Filling for switchyard 3.

Constructing access road M"3 4.

Installing utilities and construction facilities D.

Construction Schedule Mr. Kelley provided the inspectors with a master schedule concerning the project. According to Kelley, the construction starting dates of certain projects have been deferred by approximately two months. The slippage of the schedule was attributed to unusual inclement weather conditions during the.past two months and delays occasioned during the review of the design and construction specifications. The current schedule, therefore, provides that attual construction of the containment building will not begin before June; 1969.

E.

Quality Assurance - Quality Control According to Kolley, the detailed quality assurance - quality control program (QA-QC) will be formulated prior to May 1,1969. This will be from four to six weeks prior to the start of actual construction of the containment buildings' The writer informed Mr. Kelley of the Commission's interest in licensees "QA-QC" programs. Therefore, a tentative meeting to review PC&E's program in depth during the first part of May,1969 was arranged with Mr. Kelley.

+. _ _.. -, _. - _ _ _. - - _ _. - - - - -. _ _, -..... -..

e-(S

,(.DIABLOCANYONUNIT1 Table I Eeuipment List and Manufacturer

.. ~ ~

Eeulement Manufserurer (Locatio'ni Steam Generator Safety Valves Dresser Industries, Inc. (Alexandria,La.)

230/12 kv Standby-Startup Transfcrmer s McGraw Edison Co. (Canonsburg, Pa.)

12/4.16 kv St$ndby-Startup Transformers Federal Pacific Co. (Milpitas, Calif.)

25/12 kv Auxiliary Transformers Wagner Electric Sales Corp.

4 Electrical Penetrations General Electric Co. (San Jose, Calif.)

Instrument Air Compressors Joy Mfg. Co. (Michigan City, Ind.)

Instrument Air Dryers Lectrodryer Div. of McGraw Edison.

Wesrinchouse Scone of Sueolv:

(Pittsburgh, Pa.)

Reactor Vessel Internals Westinghouse (Pensacola)

Reactor Vessel Combustion Engrg.,Inc. (Chattanooga, Tenn.)

Control Rod Drive Mechanism Assemblies Westinghouse (Cheswick)

Control Rod Drive Mechanism Part Length, Rods Royal Industries (Santa Ana, Calif.)

W. Steam Generator *"

(;Aa.g$$ Reactor Coolant Pumps and Motors Westinghouse (Cheswick)

Se stinghouse - (Tampa)

M aPressurizer Westinghouse (Tampa)

Reactor Coolant Loop Fittings ESC'O Corporation (Portland, Oregon)

Reactor Coolant Loop Pipe Cameron Iron Works (Houston, Texas)

Reactor Coolant Loop Fabricati.on Southwest Fabricating and' elding (Houston, Texas)

~

  1. ' Fuel Transfer System Stearns-Roger Corporation (Denver, Colo.)

Residual Heat Removal Pumps

'Ingersoll-Rand Company Boric Acid Transfer Pumps Crane Co. (Warrington, Pa.)

CVCS Charging Pumps Union Pump Co. (Battle Creek, Mich.) '

f;,.j Cas Stripper Fced Pu.nps Crano Co. (Warrington, Pa.)

' Concentrates Holding Tank Transfer Pumps Cranc.Co. (Warrington, Pa.)

Safety Injection Pumps Pacific Pumps, Inc. (Huntington Park, Calif.)

i

. Residual Heat Exchant.crs Engineers & Fabricators, Inc.

l (Hou1 ton, Texas)

Excess " Letdown Heat Exchanger Atlas Industrial Mfg. Co. (Clif ton, N.J.)

Scal WatoreHeat Exchtnger Atlas Industrial Mfg. Co.(Clifton, N.J.)

Safety Injection Syst em Accumulators Delta Southern Co. (Baton Rouge, La.)

Press,uri::cr Safety Valves Crosby Valve & Gage Co. (Wrontham, Mass.)

Deborating Domineral'zcrs Commercial Filters Corp. (Lebanon, Ind.)

Mixed Bed Dcminerali::crs Commarcial Filters Corp. (Lcbm.un,Ind.)

^

4.

.,e.

..,l.-

. s n.,,, fci.,,1ek)

\\

l

,e o

s i

/'

i-

k.... i <.w.......

(

(..:,...

v t

t j

v 4

i CINERAL CONSTRUCTION i

VICE PRESIDENT-VICE PRES! DENT

"..'.y CcusulTAes l' ENGINEERING

, sais.

. so..s

\\

1, P gp AUTecomeTY To MANAGER

ce= omatio=

4:08 0A4 PROJECT ENGINEER STATION CONSTRUCTION r

q l*

coo.ct.,.o.m near o

no.,

I' EN u enmo DEPARTMENT OF ENGINEERING '

RESEArtCH

+.

civil ENGINEERING

  1. dM.,

7,c'c*.,",c,,,o,

WIAll5TS

==

WECHANICAL ENGINEER!hG staaoanos 3-ELECTRICAL ENGINEEltlNG I

ENGiliCLHING $[IlVICE3 e.areve tf y

CONSTRUCTION SUPER!NTENDENT Wa,",L",',c,,,

y __

1 ots;,,

4 o ara oaacs i msneviou crmoso oiascr.o.,

,O As.3 vgs, avviemvv vo V e ""

'ots'Cg FoA g

e aur,.c iry.,

ston woan aro. =cna

*""T-~"*".

CR on.s.nm.

CES:GN $TAFF seen vest ce s euanrs t

g * *"8'*6 I

EQU.< 4NT VENDORS

(,z.

7 a

ms,ecy westmswouse ano or>.cas dfc o,r,tco r w urwr acccre

, gno on w cAric=s secc.r;

~g;;

ammas,

. s.

  • %~'

0FF SITE

[.

AT SITE o,.ecvio., y i,

PROJECT SUPERINTENDENT.

DEPMTMENT CF RE5fMNT & AELD ENGINEERS AND INSPECTOR $3 t

ENGINEEAING

. svavevoes e sense.v. me=ern REYlEW GROUP

. Q.g

.ttreinecas... wetoine e ses e,erenre=nt

. c evi6

. soets

-.3..

rest re cuns

,oo,,

wo, css e.,,,,

. w o.ev t, co cnave, ion.n.cuws m,

. sinw en e co uraria ma,tstion

<6t ra

=,.cca.ses css

. =u r

co.

g; y c

,,. c.

smsen6LAress

.mor semaces staar-we nennens aovisons

. uarcoas, yosues co.to***

r

.cssts

'g tmsret#wtNTArWpe i

  • e l

m.o,,,o p; s, '

~ a, Ot#CCr

,"Nr'"

.s -

v

'aa*

v ' "' **' ""a a

a CON 3TRUCTch CONTRACTCAS

    • 1 ctVf(

svavCTveah WECMAMACAL Assos?

  • e f6ECT4. cab 8 sPECT Popesse Test

'4 9

P. G. & E. ORGANIZATION FOR QUALITY ASSURANCE blABLO CANYON FIGURE

.t

.i i

a

-. -