Text
y
.
. . . . .
, , .
JANisWMt
Docket No.
50-219
License No. DPR-16
GPU Nuclear Corporation
ATTN: Mr. P. B. Fiedler
Vice President and Director
Dyster Creek Nuclear Generating Station
P. O. Box 388
Forked River, New Jersey 08731
Gentlemen:
Subject:
Inspection Report No. 50-219/86-33
This report documents the facts associated with a question raised in NRC Inspec-
tion Report 86-04 regarding the acceptability of hydraulic control unit (HCU)
tube steel bcttom support installations and expresses NRC concerns that have
arisen as a result of your response to the question.
As described in the enclosed report and in your Licensee Event Report (LER)86-022, 80 of 137 hydraulic control units have not been properly seismically
mounted since original construction. Your analysis of the HCU mounting, after
concerns were identified by NRC, determined that 80 hydraulic control units did
not meet seismic requirements defined in the original design basis of Oyster
Creek for Seismic Class I equipment. Although most of the quality standards
involved in present day construction were not explicitly required by the regula-
tory. agency during original plant construction, the conformance to design re-
quirements as specified on drawings has always been a requirement for good con-
struction and/or erection. This HCU problem remained unidentified until recently
when the installation was questioned by an NRC inspector.
We are concerned that this problem, as well as past deficiencies in pipe sup-
ports and masonry block walls that were addressed by NRC Bulletins, appear to
,
indicate a long-term need for a higher assurance of identification and resolu-
'
tion of such problems, through additional evaluations of the as-built plant
i
l
against design requirements applicable to Oyster Creek.
We will contact you in the near future to schedule a meeting at Region I in
order to provide a forum to discuss these issues and provide you an opportunity
to explain actions you have taken or plan to take to address our concerns.
i
!
l
OFFICIAL RECORD COPY
IR OC 86-33 - 0001.0.0
01/13/871:Er>/
i
8701210292 870113
i
ADOCK 05000219
i
G
__
-
.
GPU Nuclear Corporation
2
Your cooperation with us in these matters is appreciated.
Sincerely,
William F. Kane, Director
Division of Reactor Projects
Enclosure: NRC Region I. Inspection Report No. 50-219/86-33
cc w/ encl:
M. Laggart, BWR Licensing Manager
,
Licensing Manager, Oyster Creek
Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
'
NRC Resident Inspector
State of New Jersey
bec w/ encl:
Region I Docket Room (with concurrences)
Management Assistant, DRMA (w/o enc 1)
Section Chief, DRP
Robert J. Bores, DRSS
DRS Director
DRSS Director
W. Johnston, DRS
J. Durr, DRS
J. Wiggins, DRS
D. Holody
i
/
o
,
P
RI:DRP
RI:DRP
[
Conte
Durr
Blough
e
j
1/7/87
1/f /87
1/ /87
1 /13 /8 7
i
l
w/ty
0FFICIAL RECORD COPY
IR OC 86-33 - 0002.0.0
i
01/07/87
l
l
t
- - - - .
-
_-
- , . . - - . - .
-
. . - . - .
- , - -
-- . - - - - - -
- . - -
- - - -
-
- - - .
.
.
4
V
GPU Nuclear Corporation
2
Your cooperation with us in these ma.tters is appreciated.
Sincerely,
original W W '-
William F. Kane, Director
Division of Reactor Projects
Enclosure: NRC Region I Inspection Report No. 50-219/86-33
'
cc w/ encl:
M. Laggart, BWR Licensing Manager
Licensing Manager, Oyster Creek
Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector
State of New Jersey
bcc w/ encl:
Region I Docket Room (with concurrences)
Management Assistant, DRMA (w/o encl)
Section Chief, DRP
Robert J. Bores, DRSS
DRS Director
DRSS Director
i
W. Johnston, DRS
J. Durr, DRS
J. Wiggins, DRS
D. Holody
,
9
<
RI:DRP
RI:DRP
.. RI:DRP
RI:DRP
Blough
Durr
-'Kister
Kane
41/
'86
11/ /86
11'
'86-
11/ /86
)L/wfdL
IOlkX
,
0FFICIAL RECORD COPY
IR OC 86-33 - 0002.0.0
Ob0 ch R{g(
12/15/86
,
6 %ssAa
'
A+,Q "^^{
.
)
_.
_ . _ - - _ .
-
. -
_ . .
.
. .
.-