q i

i July 31, 1985 1

MEMORANDUM FOR: Ben B. Hayes, Director Office of Investigations FROM:

Harold G. Walker, Senior Investigator Office of Investigations Field Office, Regier !!T THRU:

Eugene T. Pawlik, Director Office of Investigations Field Office, Region III

SUBJECT:

FERMI 2 NUCLEAR POWER PLANT SAFETEAM REVIEW In accordance with RIII Administrator J. G. Keppler's request in his June 13, 1985 memorandum, a comprehensive review of Detroit Edison Company's (DECO) Femi 2 SAFETEAM was conducted by 01:RIII Investigator James N. Kalkman and I, on June 11-13 and June 18-20,1985(seeattachments). The review took into consideration all aspects of the DECO SAFETEAM investigation effort as they relate to the subject of wrongdoing.

Attachments: As stated 1

Distribution:

cif s/f Fenni FAC File HGWalker

h. '

I Office:

01:RIII 01:RIII Surname: HGWalker:np ETPawlik e607230373 e60714 Date:

07/ /85 07/30/85 gTE 86-245 PDR

~

UNITED ST ATES

..a so..,, '%

NUCLEAR REGULATORY COMMtsslON

-[.>,r.

Rf GioA lit c

8

(,

vs, moest vs Li acao c b.}~,5[j' cLth r Lov%. iLLimois sois?

g,,

.c JUN 1 ? b.;

MEMORANDUM FOR:

Ben B. Hayes, Director, Office of Investigations FROM:

James G. Keppler, Regional Administrator, Region III 5'JEJECT:

REQUEST FOR PROGRAM REVIEW 0F THE FERM' StJt!El,".

s..

As discussed during the conference call of June 10, 1985, the Office of Investigations is requested to conduct a program review of the SAFETEAM at the Enrico Fermi Nuclear Plant, Unit 2.

The objective of this review is to assess the adequacy and effectiveness of the SAFETEAM program and its implementation ire the identification, dispositioning and resolution of both the technical and wrongdoing issues.

The region will provide the necessary technical support.

In order to act on the review findings before the scheduled July Comission hearing on a full power license, we believe the fact finding review must be completed by June 21, 1985.

.%& A-

~

James G. Kepp"ler Regional Administrator cc:

H. R. Denton, NRR J. M. Taylor, IE E. T. Pawlik, 01:RIII G

@FCTEAm ge re co

  • d

'o UNITED STATES

['

NUCLEAR REGULATORY COMMISSION j 2.

E W ASH *NGTON. D C. 20555 vl

,,b __,._ _ '__

e f

/__. h<

o...+

AU: 1 6 ?995

~_.Z. ti l M-i Int A MEMORANDUM FOR:

B. J. Youngblood, Chief Licensing Branch #1 Division of Licensing Office of Nuclear Reactor Regulation Walter P. Haass, Vendor Programs Branch Division of Quality Assurance, Vendor and Technical Training Center ?rograms Office of Inspection and Enforcement FROM:

James M. Taylor, Director Office of Inspection and Enforcement

SUBJECT:

YOUR JOINT MEMORANDUM CONCERNING AUDIT OF SAFE TEAM ACTIVITIES AT FERMI 2 I have reviewed you memorandum concerning the audit of Safe Team Activities at FERMI 2.

I appreciate your efforts in support of NRR, IE and Region III.

I did have difficulty correlating your findings of process deficiencies with your conclusion that the " program appears to be generally adequate and is implemented in a generally acceptable manner." Even without specific regulatory guidance at this time, I would reserve that type statement for a program with fewer deficiercies such as you noted.

Most importantly you noted no significant safety problems, a conclusion shared by Region III personnel who also reviewed / inspected the FERMI program.

J mes M. Tay r, Director fice of I pection and Enforcement cc:

J. Keppler, R-III C. Weil, R-III /

T. Novak, NRR J. Partlow, IE B. Grimes, IE