s-

[pM8c

  1. o, UNITED STATES w#

8' NUCLEAR REGULATORY COMMIS$10N e

t WASHINGTON,0. C. 20555

\\*****/

October 4, 1985 l

MEMORANDUM FOR:

James G. Keppler Region III 4Re ional A ministrator, W) se-P en. Haye,

irector /

FROM:

Office of Investigation 5

SUBJECT:

REQUEST FOR PROGRAM REVIEW 0F THE FERMI SAFETEAM PROGRAM In response to your request for a review of the Fermi Safeteam Program, 01 During conducted an analysis of documentation compiled by the Fermi Safeteam.

the review this office checked the stipulated program for overall adequacy and effectiveness.

In addition, the Safeteam Program was specifically checked to determine how issues of potential safety significance and/or wrongdoing were identified, investigated and ultimately resolved.

As a result of the OI review it was determined that the Fermi Safeteam Program was not staffed or supervised by experienced investigative personnel.

It was also y

discovered that interviews, in many cases, lacked sufficient information because of this apparent inexperience. 01 bases this conclusion on the fact that the interviews which were reviewed in the investigative files could not provide information concerning basic questions such as who, what, where, when, how and why. The Fermi Safeteam Program therefore did not exhibit the characteristics normally attributed to an investigative activity.

Enclosed is the Office of Investigations' (01) completed review of the captioned subject.

Enclosure:

As stated cc w/ encl:

W. J. Dircks, E00

/E.T. Pawlik,01:RIII t

8607230369 e60714 FOIA PDR PDR PUNTENN06-245 7

i