AVERAGE DAILY UNIT POWER LEVEL Docket No. 50-317 Calvert Cliffs Unit No. 1 Date:
June 10, 1936 Completed by R. Porter Telephone: (301) 260-4868 DECEMBER Average Daily Power Level Average Daily Power Level Day (MWe-Net)
DR (MWe-Net) j 1
876 17 877 2
876 18 879 3
867 19 878 4
871 20 877 5
877 21 879 6
877 22 879 7
876 23 879 8
876 24 880 9
875 25 879 10 876 26 878 11 878 27 877 12 876 28 879 13 878 29 878 14 879 30 878 15 880 31 877 16 878 INSTRUCTIONS:
On this format, list the average daily unit power level in.
MWe-Net for each day in the reporting month.
Compute to the nearest whole megawatt.
8606230180 860610 ADOCK0500g7 DR
OPERATING DATA REPORT Docket No. 50-317 Date:
June 10, 1986 Completed by R. Porter Telephone: (301) 260-4868 i
OPERATING STATUS
- 1. Unit Name:
Calvert Cliffs No. 1
- 2. Reporting Period:
DECEMBER
- 3. Licensed Thermal Power (MWT):
2,700
- 4. Nameplate Rating (Gross MWe):
918
- 5. Design Electrical Rating (Net MWe):
845
- 6. Maximum Dependable Capacity (Gross Mwe):
860
- 7. Maximum Dependable Capacity (Net MWe):
825 J
- 8. Change in Capacity Ratings:
None
- 9. Power Level to Which Restricted (Net MWe):
N/A
- 10. Reasons for Restrictions:
N/A This Month Yr-to-Date Cumulative
- 11. Hours in Reporting Period 744 8,760 93,373
- 12. Number of Hours Reactor was Critical 744.0 5,367.6 72,865.5
- 13. Reactor Reserve Shutdown Hours 0.0 1,034.3 3,019.4
]
- 14. Hours Generator On-Line 744.0 5,188.7 71,359.5
- 15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
- 16. Gross Thermal Energy Generated (MWH) 1,996,788 13,541,456 177,324,193
- 17. Gross Electrical Energy Generated (MWH) 680,052 4,559,432-58,602,812
- 18. Net Electrical Energy Generated (MWH) 652,512 4,359,729 55,916,295
- 19. Unit Service Factor 100.0 59.2 76.4
- 20. Unit Availability Factor 100.0 59.2 76.4
- 21. Unit Capacity Factor (Using MDC Net) 106.3 60.3 73.1 f
- 22. Unit Capacity Factor (Using DER Net) 103.8 58.9 70.9
- 23. Unit Forced Outage Rate 0.0 16.3 9.1
- 24. Shutdowns Scheduled Over Next Six Months (type,_date and duration):
None 3
- 25. If Shutdown at End of Report Period, Estimated Date of Startup:
N/A
. - -.. N
f OPERATING DATA REPORT Docket No. 50-318 Date:
June 10, 1986 Completed by R. Porter Telephone: (301) 260-4868 OPERATING STATUS
- 1. Unit Name:
Calvert Cliffs No. 2
- 2. Reporting Period:
DECEMBER
- 3. Licensed Thermal Power (MWT):
2,700
- 4. Nameplate Rating (Gross MWe):
918
- 5. Design Electrical Rating (Net MWe):
845
- 6. Maximum Dependable Capacity (Gross Mwe):
860
- 7. Maximum Dependable Capacity (Net MWe):
825 8.
Change in Capacity Ratings:
None
- 9. Power Level to Which Restricted (Net MWe):
N/A
- 10. Reasons for Restrictions:
N/A This Month Yr-to-Date Cumulative
- 11. Hours in Reporting Period 744 8,760 76,728
- 12. Number of Hours Reactor was Critical 551.3 6,884.2 63,443.0
- 13. Reactor Reserve Shutdown Hours 0.0 292.7 1,260.7
- 14. Hours Generator On-Line 488.5 6,792.0 62,411.3
- 15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
- 16. Gross Thermal Energy Generated (MWH) 1,082,986 17,761,099 156,482,036
- 17. Gross Electrical Energy Generated (MWH) 365,752 5,863,321 51,521,524
- 18. Net Electrical Energy Generated (MWH) 347,489 5,608,049 49,150,257
- 19. Unit Service Factor 65.7 77.5 81.3
- 20. Unit Availability Factor 65.7 77.5 81.3
- 21. Unit Capacity Factor (Using MDC Net) 56.6 77.6 77.9
- 22. Unit Capacity Factor (Using DER Net) 55.3 75.8 75.8
- 23. Unit Forced Outage Rate 4.0 5.6 6.2
- 24. Shutdowns Scheduled Over Next Six Months (type, date and duration):
None
- 25. If Shutdown at End of Report Period, Estimated Date of Startup:
N/A l
AVERAGE DAILY UNIT POWER LEVEL Docket No. 50-318 Calvert Cliffs Unit No. 2 Date:
June 10, 1986 Completed by R. Porter Telephone: (301) 260-4868 DECEMBER Average Daily Power Level Average Daily Power Level Day (MWe-Net)
Day (MWe-Net) 1 0
17 830 2
0 18 579 3
0 19 580 4
0 20 627 5
0 21 847 6
0 22 852 7
0 23 795 8
0 24 850 9
0 25 852 10 0
26 856 11 330 27 877 12 4
28 880 13 377 29 881 14 391 30 880 15 641 31 881 16 669 INSTRUCTIONS:
On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.
Compute to the nearest whole megawatt.
)