CONTAIMEML3Y1TEMS 00NTAIMENT LEAKAfd LIMITING CONDITION FOR OPERATION u_

3.6.1.2 Containment leakage rates shall be in accordance with the Containment Leakage Rate Testing Program.

APPLICABILITY: MODES 1, 2, 3, and 4.

EllM:

With containment leakage rate P-t within limits, restore containment leakage rates to wit'in limits prior to increasing the Reactor Coolant System a

temperature above 200*F.

SURVEILLANCE REQUIREMENTS 4.6.1.2 The containment leakage rates shall be determined in accordance with the Containment Leakage Rate Testing Program.

9710010225 970925 PDR ADOCK 05000382 P

PDR WATERFORD - UNIT 3 3/4 6-2 AMEN 0MENTHO.g05,110,

[pNTAI! MENT LEAKAGE RATE TESTING PROGRAM (Continued)

. Leakage rate acceptance criteria are:

a.

Containment leakage rate acceptance criteria is 1 1.0 1.,.

During the first unit startup following each test performed in accordance with thisarogram, the leakage rate acceptance criteria are 10.60 L, for the Type B and Type C tests and 10.75 L, for Type A tests, b.

Air lock acceptance criteria are:

1.

Overall air lock leakage rate is s 0.05 L, when tested at 1 P.

2.

Leakage rate for each door is s 0.01 L, when pressurized to 110 psig.

c.

Combined bypass leakage rate acceptance criteria is 10.06 L, when tested at 1 P,.

(

d.

Containment purge valves with resilient seals acceptance criteria is s 0.06 L, when tested at 1 P.,

The provisions of Specification 4.0.2 do not apply to the test frequencies specified in the Containment Leakage Rate Testing Program.

The provisions of Specification 4.0.3 are applicable to the Containment Leaktje Rate Testing Program.

' q.

c

.", N 14.),

f:

WATERFORD - UNIT 3 6-25 Amendment No.124

E S

4 e

NPF-38-201 ATTACHMENT B

CONTAINMENT SYSTEMS CONTAINMENT LEAKAGE LIMITING CONDITION FOR OPERATION 3.6.1.2 The overall Cgontainment leakage rates and the secondary containment bvonss leakaog talg shall be in accordance with the Containment Leakage Rate Testing Program.

APPLICABILITY: MODES 1,2,3, and 4.

ACTION:

Witn the overall containment leakage rate and/or the secondary containment bvnnce leaknoe rate not within limits, restore containment ieakage rate (s) to within limits within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or be in at least HOT STANDslY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> arid in' COLD SHUTDOWN within the followino 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIRFMENTS 4.6.1.2 The nyrall containment leakage rates and the secondary bvoass feakaoe rate shall be l

determined in accordance with the Containment Leakage Rate Testing Program.

WATERFORD - UNIT 3 3/4 6-2 AMENDMENT NO. 75r85 440 7

424

, CONTAINMENT LEAKAGE RATE TESTING PROGRAM (Continued)

- Leakage rate acceptance criteria are:

a.

QuaralLCcontainment leakage rnte acceptance criteria is s 1.0 La. During the first unit startup following each test perfoimed in accordance with this program, the.qvgall containment leakage rate acceptance criteria are s 0.60 La for the Type B and Type C tests and s 0.75 La for Type A tests.

b.

Air lock acceptance criteria are:

1.

Overall air lock leakage rate is s 0.05 La when tested at 2 Pa-

- 2.

Leakage rate for each door.htalis s 041 Q.QQ5 La when pressurized l

to 210 psig.

c.

secondarv containment Combined bypass leakage rate acceptance criteria is s 0.06 La when j tested at 2 Pa.

d.

Containment purge valves with resilient seals acceptance criteria is s 0.06 La when tested at 2 Pa-The provisions of Specification 4.0.2 do not apply to the tcst frequencies specified in the Containment Leakage Rate Testing Program.

The provisions of Specification 4.0.3 are applicable to the Containment Le,nkage Rate Testing Program.

WATERFORD - UNIT 3 6-25 AMENDMENT NO. 424-124 l I

9,

O 4

0 4

NPF-38-201 ATTACHMENT C

~

= QQNTAINMENT SYSTEMS

- CONTAINMENT LEAKAGE

. LIMITING CONDITION FOR OPERATION 3.6.1.2 The overall containment leakage rate and the secondary containment bypass hakage rate l

shall be in accordance with the Containment Leakaga Rate Testing Program.

APPLICABILITY: MODES 1,2,3, and 4.

6CTION With the overall containment leakage rate and/or the secondary containment bypass leakage rate not within limits, restore containment leakage rate (s) to within limits within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIRFMFNTS 4.6.1.2 The overall containment leakage rate and the secondary bypass leakage rate shall be l

determined in accordance with the Containment Leakage Rate Testing Program.

WATERFORD - UNIT 3 3/4 6-2 AMENDMENT NO. 76r85 440, 7

424

. CONTAINMENT LEAKAGE RATE TESTING PROGRAM (Continued)

Leakage rate acceptance criteria are:

Overall containment leakage rate acceptance criteria is s 1.0 La. During the first unit startup a.

following each test performed in accordance with this program, the overall containment leakage rate acceptance criteria are s 0.60 La for the Type B and Type C tests and s 0.75 La for Type A tests.

b.

Air lock acceptance criteria are:

1.

Overall air lock leakage rate is s 0.05 La when tested at 2 Pa-2.

Leakage rate for each door sealis s 0.005 Lawhen pressurized l

l to 210 psig.

l Secondary containment bypass leakage rate acceptance criteria is s 0.06 La when tested c.

at 2 Pa-d.

Containment piirge valves with resilient seals acceptance criteria is s 0.06 La when tested at 2 Pa-The provisions of Specification 4.0.2 do not apply to the test frequencies specified in the Containment Leakage Rote Testing Program.

Tne provisions of Specification 4.0.3 are applicable to the Containment Leakage Rate Testing Program, i

WATERFORD - UNIT 3 6-25 AMENDMENT NO. 434 l


--_-_ __