ML20211F809

From kanterella
Jump to navigation Jump to search
Application for Amend to License NPF-38,modifying LCO 3.6.1.2, Containment Leakage, Associated Action & SR 4.6.1.2
ML20211F809
Person / Time
Site: Waterford 
Issue date: 09/25/1997
From: Dugger C
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20211F812 List:
References
W3F1-97-0233, W3F1-97-233, NUDOCS 9710010223
Download: ML20211F809 (12)


Text

C

()

fnrgy per;tions, inc.

Of Kdluna LA /n(06 0751 Td 604 739 M60

.:m W3F197-0233 A4.05 PR September 25,1997 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Technical Specification Change Request NPF-38 201 Gentlemen:

The attached description and safety analysis support a change to the Waterford 3 Technical Specifications (TS). The proposed change modifies Limiting Condition for Operation (LCO) 3.6.1.2 (Containment Leakage), the asscciated Action, and Surveillance Requirement (SR) 4.6,1.2. Technical Specification 6.15 air lock door seal leakage rate acceptance criteria is being changed from 0.01L, to 0.005L,.

Technical Specification 6.15 is also being modified to make the terms used in the Containment Leakage Rate Testing Program consistent with terms used in the TS.

This change corrects an error that inadvertently decreased the allowed outage time from 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> when the containment purge valve or containment air lock leakage rates are not within limits. This error was made in the Waterford 3 TS change request that was approved in Amendment 124. It was not the intent of

/

Waterford 3 nor 10CFR50 Appendix J, Option B to decrease thesa allowed outage 7

times. This TS change request justifies revising TS 3.6.1.2 to reference the specific TS for which it applies, in doing so, TS 3.6.1.3 (Containment Air Locks) will be

,4 ij f entered when the containment air lock leakage rate is not within limit and TS 3.6.1.7 t

(Containment Ventilation Systems) will be entered when the containment purge valve leakage rate is not within limits. This will restore the allowed outage time to the pre-Amendment 124 time of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the containment purge valve or containment air lock leakage rates are not within limits.

9710010223 970925 5"

^

88*"1 IggiIIIIR!I@il

4 Technical Specification Change Request NPF-38-201 W3F197-0233 Page 2 September 25,1997 Waterford 3 is also proposing to change the air lock door sealleakage rate acceptance criteria to the pre-Amendment 124 value. The value was inadvertently changed when Waterford 3 utilized the model TS associated with NEl Guidelines for adopting 10CFR50, Appendix J, Option B. The change inadvertently revised the acceptance criteria to a less restrictive value. However, the less restrictive acceptance criteria was never utilized at Waterford 3. Plant Procedures continue to implement the more restrictive acceptance criteria.

This proposed change has been evaluated in accordance with 10CFR50.91(a)(1),

using the criteria in 10CFR50.92(c), and it ! as been determined that this request involves no significant hazards consideration.

The circumstances surrounding this change do not meet the NRC's criteria for exigent or emergency review. However, due to the possibility of an unnecessary plant shutdown if a purge valve or containment air lock fails the leakage test while at power, an expeditious reviaw is requested.

Should you have any questions or comments concerning this request, please contact Mr. Early Ewing at (504)739-6242.

Very truly yours,

'l v'

1 C.M. Dugger Vice President, Operations Waterford 3 CMD/CED/ssf

Attachment:

Affidavit NPF-38-201 cc:

E.W. Merschoff (NRC Region IV), C.P. Patel (NRC-NRR),

J. Smith, N.S. Reynolds, NRC Resident Inspectors Office, AdminisVator Radiation Protection Division (State of Louisiana),

American Nuclear Insurers

t UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the matter of

)

)

Entergy Operations, incorporated

)

Docket No. 50 382 Waterford 3 Steam Electric Station

)

AFFIDAVIT bi dl h

bd d

h Charles Marsha.

.gger, e ng u y sworn, ere y eposes an says t at e sh i Vice President Operations - Waterford 3 of Entergy Operations, Incorporated; that he is duly authorized to sign and file with the Nuclear Regulatory Commission the attached Technical Specification Change Request NPF-38 201; that he is familiar with the content thereof; and that the matters set forth therein are true and correct to the best of his knowledge, information and belief.

k MA w Charles Marshall Dugger oV Vice President Operations - Waterford 3 STATE OF LOUISIANA

)

) ss PARISH OF ST, CHARLES

)

t Subscribed and sworn to before me, a Notary Public in and for the Parish and State above named this e r '3 day of _

, 2 Z _,_,1997.

m f e c-d LY' Notary Public My Commission expires M c/wM,

DESCRIPTION AND NO SIGNIFICANT HAZARDS CONSIDERATION OF PROPOSED CHANGE NPF-38-201 The proposed change revises the Technical Specifications (TS) as follows:

Limiting Condition for Operation (LCO) 3.0.1.2, " Containment Leakage" is revised to specify that "overall containment leakage rate" and the " secondary containment bypass leakage rate" are the containment leakage rates that apply to this LCO.

f Surveillance Requirement (SR) 4.6.1.2 is revised to be specific by referring to the "overall containment leakage rate" and the " secondary containment bypass leakap rate'.

TS 3.6.1.2 Action is revised to be s,cecific by re' erring to the "overall containment leakage rate" and the " secondary containment bypass leakage rate *. The Action is also being revised tc make the Action consistent with the Applicability and NUREG-1432 (Revised Combustion Engineering Standard Technical Specifications) TS 3.6.1 Action.

TS 6.15 air lock door seal leakage rate acceptance criteria is revised to s 0.005L,.

TS 6.15 is reved to make the terms used in the Containment Leakage Rate Testing Program consistent with terms used h the TS.

Existing Specificatio2 See Attachment A Markad-up Specification i

See Attachment B Proposed Specification See Attachment C 1

===.

Background===

s License Amendment 124 (issued on April 10,1997) revised TS Sections 3.6 and 6.0 to incorporate 10 CFR50 Appendix J, Option B. Waterford 3 used the NEl guidelines (Nuclear Energy Institute Industry Guideline for Implementing Performance-Based Option of 10 CFR Part 50, Appendix J) to develop this change. The NEl guidelines

,[

consisted of marked-up pages from the Improved Standard Technical Specifications E

(ISTS). Waterford 3 only adopted the changes that specifically dealt with 10CFR50 Appendix J, Option B and improvements associated with the ISTS were not incorporated. An error was introduced in the Waterford 3 proposed TS change request as a result of this conversion. The error affects the TS by requiring entry into TS 3.6.1.2 when either the containment air lock or the containment purge valve leakage 1b rates are not within limits, along with entering TS 3.6.1.7 (Containment Ventilation System) or TS 3.6.1.3 (Containment Air Locks). Since TS 3.6.1.2 has a more restrictive allowed outage time (1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> via entry into TS 3.0.3) than either TS 3.6.1.3 or TS 3.6.1.7 (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />), the 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> AOT in TS 3.6.1.2 would be the most limiting.

Prior to Amendment 124, TS 3.6.1.2 contained the acceptance criteria (i.e., leakaoe limits) for the overail containmert leakage rate and the secondary containment bypass

}

leakage rate. The associated surveillance requirements in TS 3.6.1.2 required the airlock / door seal and purge valve surveillances to be conducted as specified in their individual LCOs (i.e., TS 3.6.1.3 " Containment Air Locks" and 3.6.1.7 " Containment Ventilation System"). This change proposes to make a less restrictive change to the Waterford 3 TS to restore the pre-Amendment 124 TS requirement to only enter TS 3.6.1.3 or TS 3.6.1.7 when either the containment air locks or the containment purge valve acceptance criteria are not met and not enter TS 3.6.1.2 unless the overall containment leakage or secondary bypass leakage also exceeds the specified limits.

E Prior to Amendment 124, TS 3.6.1.3 SR 4.6.1.3.a contained the requirement that each air lock door seal leakage rate be verified to be s 0.005L,. The NEl guidelines moved this acceptance criteria to TS 6.15. The NEl guideline model TS contained an acceptance criteria for the air lock door seal leakage rate of s 0.01L, which was inadvertently copied into the Waterfor.? 3 proposed change.

Description and Safety Considerations Technical Specification LCO 3.6.1.2 requires the containment leakage rates to be in accordance with the Containment Leakage Rate Testing Program. If the containment

^

=

leakage rates cannot be maintained, the Action requires the leakage rates to be restored to within limits prior to increasing the Reactor Coolant System temperature 2

above 200 F. Surveillance Requirement (SR 4.6.1.2) requires the containment leakage rates to be determined in accordance with the Containment Leakage Rate Testing Pm',. a m.

The proposed change will add the specific types of containment leakage that apply to LCO 3.6.1.2, the associated Action, and SR 4.6.1.2. The LCO is modified to require the overall containment leakage rate and the secondary containment bypass leakage rate to be in accordance with the Containment Leakage Rate Testing Program. The Action is modified to require the contairsment leakage rate (s) to be restored within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or to be in Hot Standby within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and Cold Shutdown within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. The SR is modified to require the overall containment leakage rate and the secondary containment bypass leakag? rate to be determined in accordance with the Containment Leakage Rate Testing Piogram. This properly identifies the leakage rates that apply to TS 3.6.1.2 and maintains the allowance for entry into TS 3.6.1.3 or Tb 3.6.1.7 when the leakage rate acceptance criteria for the containment air locks or containment purge valves, respectively, are not within limits.

This is a less restrictive change that increases the AOT from 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when either tne containment air lock or the containment purge valve leakage rates are not within limits. This change ic acceptable based on the reasons described below. The overall containment leakage rate limits are not being changed (any leakage from the containment purge valves or from the air lock are required to be added to t'e overall leakage rate) and, therefore, the safety analysis containment !eakage rate assumptions are being maintained. The increased AOT allows time 'o repair the leakape while limiting the time in the degraded condition. The longer period of time to perform repairs to restore the leakage rates may prevent a plant shutdown. A plant shutdown is a transient that places thermal stress on safety system components. Finally, this change restores the Waterford 3 AOTs, when the containment purge valve or containment air lock leakage rates are not within limits, to the pre-Amendment 124 AOTs which were inadvertently changed due to an error in the Waterford 3 TS change eubmittal.

The change also proposes to revise the air lock door seal leakage rate acceptance criteria in TS 6.15.b.2 from 0.01L, to 0.005L,. This is a more restrictive change to correct an error that was made while incorporating the provisions into the TS to implement 10CFR50 Appendix J Option B criteria. The NEl guidelines that were used to develop the proposed change contained a less restrictive air lock door seal leakage rate acceptance criteria of 0.01L. The less restrictive value was in brackets meaning that a site specific value was re luired. However, Waterford 3 inadvertently adopted this value which was incorporated in Amendment 124. Toe less restrictive value of 0.01L, har. never been used as the acceptance criteria for the air lock door seal leakage rate Waterford 3 procedures currently contain an air lock door seal leakage rate acceptance criteria equal to 0.005L,. Waterford 3 will continue using the more restrictive air lock door seal leakage rate acceptance criteria, which is controlled administratively.

3

This change also includes administrative changes to TS 3.6.1.2 and TS 6.15.

The current TS 3.6.1.2 Action requires RCS temperature to not exceed 200 F if the containment leakage rates are not within limits. The temperature of 200 F is the transition temperature between Modes 5 and 4. This Action is isot consistent with the

]~

Applicability for TS 3.6.1.2 (Modes 1,2,3, and 4). The Action is being changed to require containment leakage rate (s) to be restored within limits within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or be in Mode 3 in 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and Mode 5 in the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. This change is acceptable because the Action and the Applicability will be consistent, and the requirement not to exceed 200 F is captured in TS 3.0.4 which does not allow Mode changes unless the requirements of the limiting condition for operation are satisfied for the higher mode.

The change to TS 6.15 proposes to make the containment leakage rate terms used in the TS and the Containment Leakage Rate Testing Program consistent. Currently 6.15.a refers to the containment leakage rate acceptance critet:a, TS 6.15.b.2 refers to the leakage rate for each (air lock) door, and TS 6.15.c refers to combined bypass leakage rate. The proposed change revises TS 6.15.a to refer to the overall containment leakage rate, TS 6.15.b.2 to refer to the leakage rate for each (air lock) door seal, and TS 6.15.c to refer to the secondary containment bypass leakage rate.

This is an administrative change which makes the containment leakage rate terms in TS Section 3.6, TS Section 6.0, and the Containment Leakage Rate Testing Program consistent.

No Significant Hazards Consideratio_n The proposed change described above shall be deemed to involve a significant hazards consideration if there is a positive finding in any of the following areas:

1.

Will operation of the facility in accordance with this proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?

Response

No The proposed change adu the specific type cf containment leakage to the I

Limiting Condition for U. W tion (LCO), Action, and Surveillance Requirement (SR) in the Containmem teakage Technical Specification (TS) which results in increasing the allowed outage time from 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the containment purge valve or containment air lock leakage rates are not within limits. The proposed change revises the air lock door sealleakage rate acceptance criteria. Also, the proposed change revises the Actions in the Containment Leaxage TS to be consistent with the Applicability, and revises

(

4

terms in the Containment Section and Administrative Controls Section of the TS to be consistent with the Containment Leakage Rate Testing Program. This change will not affect the probability of an accident. The containment purge valve and air lock leakage rates are not an initiator of any analyzed event. This change corrects two errors that were made in the Waterford 310CFR50 Appendix J. Option B, TS change request that was approved in TS Amendment 124. The first error inadvertently decreased the allowed outage time from 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> when either the containment purge valve or containment air lock leakage rate acceptance criteria is not met. The second error inadvertently increased the acceptance criteria for the air lock door sealleakage. The revised air lock door seal leakage rate acceptance criteria was never used at Waterford a

3. This change also administratively changes the Containment Leakage i S Action and terms in the TS for consistency.

The proposed change will not affect the consequences of an accident. The amount of leakage from the containment purge valve and from the cont #1 ment air lock will still be included in the overall combined containment leak rate.

Neither the overall containment leakage rate limit nor the Action required to be taken if the overall containment leakage rate were exceeded is being changed.

The Containment Leakage TS Action will be consistent with the Applicability and TS 3.0.4 will prohibit entry into Mode 4 (RCS temperature > 200 F), unless the overall containment leakage rate is witton limit. The revised air lock accaptance criteria was never used. Waterford 3 will continue using the more restrictive acceptance criteria which is controlled administratively. This proposed change does not affect the mitigation capabilities of any component or system, nor does it affect the assumptions relative to the mitigation of accidents or transients.

Therefore, the proposed change will not involve a significant increase in the probability or consequences of any accident previously evaluated.

2.

Will operation of the facility in accordance with this proposed change create the possibility of a new or different type cf accident from any accident previously evaluated?

Response

No.

The proposed change adds the specific type of containment leakage to the LCO, Action, and SR in the Containment Leakage TS. This results in increasing the allowed outage time from 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the containment purge valve or containment air lock leakage rates are not within limits. The proposed change revises the air lock door seal leakage rate acceptance criteria. Also, the proposed change revies the Actions in the Containment Leakage TS to be consistent with the Applicability, and revises terms in the Containment Section 5

l.-_______-_-_

and Administrative Controls Section of the TS to be consistent with the Containment Leakage Rate Testing Procram. Neither the design nor configuration of the plant, or how the plant is operated is being changed due to the addition of the specific types of leakage frcm the Corstriment Leakage Rate Testing Program, corrections made to the air lock door

.ileakage rate

]

acceptance criteria, or the changes made to make the

, consistent. There has been no physical change to plant systems, structures, or components nor will these changes reduce the ability of any of the safety-related equipment required to mitigate anticipated operational occurrences or accidents. Therefore, the proposed change will not create the possibility of a new or different kind of accident from any accident previously evaluated.

3.

Will operation of the facility in accordance with this proposed change involve a significant reduction in a margin of safety?

Response

No The proposed change adds the specific type of containment leakage to the LCO, Action, and SR in the Containment Leakage TS. This results in increasing the allowed outage time from 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the containment purge valve or containment air lock leakage rates are not within limits. The proposed change revises the air lock door sealleakage rate acceptance criteria. Also, the proposed change revises the Actions in the Containment Leakage TS to be consistent with the Applicability, and revises terms in the Containment Section and Administrative Controls Section of the TS to be consistent with the Containment Leange Rate Testing Program. The proposed revision to the Action and making the containment leakage rate terms consistent are administrative changes that have no technical impact on the TS.

The pre-amendment 124 Waterford 3 TS and NUREG-1432 allowed entry into specific Actions with allowed outage times greater than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />) when the air lock and purge valve leakage rate acceptance criteria could not be met.

This change restores this allowed outage time which was inadvertently changed due to an error in the TS change request. The increased allowed outage time may prevent an unnecessary plant shutdown which is a plant transient. Plant shutdowns produce thermal stress on components in the Reactor Coolant System and the potentid for a plant upset that could challenge safety systems.

This change decreases the possibility of a plant shutdown by replacing the 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> allowed outage time with a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowed outage time when the containment purge valve or containment air lock leakage is not within limits.

Also, the overall containment leakage rate limits are not being changed and are required to be maintained.

6

l.

The revision to the air lock door seal acceptance criteria is a more restrictive change to correct an error made by Waterford 3 in the TS change request approved in Amendment 124. The less restrictive acceptance criteria was never used; Waterford 3 continued testing to the more restrictive acceptance criteria.

Therefore, the proposed change will not involve a significant reduction in a margin of safety.

Gafety and Significant Hazards Determination Based on the evaluation above, it is concluded that: (1) the proposed change does not constitute a significant hazards consideration as defined by 10CFR50.92; and (2) there is a reasonable assurance that the health and safety of the public will not be endangered by the proposed change; and (3) this action will not result in a condition which significantly alters the impact of the station on the environment as described in the NRC final environmental statement.

Environmental Assessment This proposed Technical Specification change has been evaluated against criteria for and identification of licensing and regulatory actions requiring environmental assessment in accordance with 10CFR51.21. It has been determined that the proposed change meets the criteria for categorical exclusion as provided for under 10CFR51.22(c)(9). The following is a discussion of how the proposed Technical Specification change meets the criteria for categorical exclusion.

10CFR51.22(c)(9): Although the proposed change involves revising requirements with respect to inspection or Surveillance Requirements, (i) the proposed change involves No Significance Hazards Consideration (refer to the No Significance Hazards Consideration Determination section of this Technical Specification Change Request);

(ii) there are no significant changes in the types or significant increase in the amounts of any effluents that may be released offsite since the proposed change does not affect the generation of any radioactive effluents nor does it affect any of the permitted release paths; and (iii) there is no significant increase in individual or cumulative occupational radiation exposure.

7

Accordingly, the proposed change meets the eligibility criteria for categorical exclusion set forth in 10CFR51.22(c)(9). Based on the aforementioned and pursuant to 10CFR51.22 (b), no environmental assessment or environmental impact statement need be prepared in connection with issuance of an amendment to the Techn: cal Specification incorporating the proposed change of this request.

8

__.------_____.__----,-,,-,,--,-----,__w----------------

G e

1 4

6 NPF-38-201 r

(

ATTACHMENT A a

___ _