y Docket Nos.: 50-413 and I
50-414 10 JUN 1986 Mr. H.B. Tucker, Vice President Nuclear Production Department Duke Power Company 422 South Church Street Charlotte, North Carolina 28242
Dear Mr. Tucker:
SUBJECT:
Catawba Nuclear Station Units 1 and 2 - Transmittal of a Draft Safety Evaluation Report on Generic Letter 83-28, Items 4.1, 4.2.1 and 4.2.2.
By letter dated June 24, 1985, you responded to Generic Letter 83-28, items 4.1, 4.2.1 and 4.2.2 regarding the preventative maintenance program for reactor trip breakers / maintenance and trending. The enclosed draft safety evaluation report was prepared by the NRC staff based upon input from our contractor, Idaho National Engineering Laboratory, after having reviewed your responses.
The draft SER concludes that for item 4.1 your response is acceptable, how-ever, for items 4.2.1 and 4.2.2 your responses did not meet the staff's criteria and therefore were unacceptable.
Please provide the additional information requested in the enclosed draft SER within 60 days of the date of this letter. Should you have questions regarding the enclosure or be unable to meet the requested response date, contact the Project Manager, Kahtan Jabbour, at (301) 492-7367.
NS\\
B.J. Youngblood, Di~ rector PWR Project Directorate #4 Division of Licensing-A
Enclosure:
As stated cc: See next page DISTRIBUTION Ypocket. File BGrimes "NRC* PDR "* ' -
JPartlow PDR#4 Reading ACRS(10)
KJabbour MDuncan BJYoungblood OELD EJordan PWRf4 D WR-A PWR /)PWR-A PWR#4/DPWR-A KJabbour/ rad Mbu hh 4n BJYoungblood 06/q/86 06/./86 06/4/86 8606130339 860610 PDR ADOCK 05000413 P
e Kutuq%
UNITED STATES 8
NUCLEAR REGULATORY COMMISSION o
a wAsHWGTON, D. C. 20555
%,*.,*/
10 JUN 1986 Docket Nos.: 50-413 and 50-414 Mr. H.B. Tucker, Vice President Nuclear Production Department Duke Power Company 422 South Church Street Charlotte, North Carolina 28242
Dear Mr. Tucker:
SUBJECT:
Catawba Nuclear Station Units 1 and 2 - Transmittal of a Draft Safety Evaluation Report on Generic Letter 83-28. Items 4.1, 4.2.1 and 4.2.2.
By letter dated June 24, 1985, you responded to Generic Letter 83-28, items 4.1, 4.2.1 and 4.2.2 regarding the preventative maintenance program for reactor trip breakers / maintenance and trending. The enclosed draft safety evaluation; f
report was prepared by the NRC staff based upon input from our contractor, Idaho National Engineering Laboratory, after having reviewed your responses.
The draft SER concludes that for item 4.1 your response is acceptable, how-i ever, for items 4.2.1 and 4.2.2 your responses did not meet the staff's criteria and therefore were unacceptable.
i Please provide the additional information requested in the enclosed draft SER within 60 days of the date of this letter.
Should you have questions regarding the enclosure or be unable to meet the requested response date, contact the Project Manager, Kahtan Jabbour, at (301) 492-7367.
Sincerely, fas B.J. Youngblood, Director PWR Project Directorate #4 Division of Licensing-A
Enclosure:
As stated cc: See next page r--,
- - ~, - -
.------e,,-.-----
,,, -., -, -.., - - - - =
Mr. H. B. Tucker Duke Power Company Catawba Nuclear Station 4
cc:
William L. Porter, Esq.
North Carolina Electric Membership Duke Power Company Corp.
P.O. Box 33189 3333 North Boulevard l
Charlotte, North Carolina 28242 P.O. Box.27306 Raleigh, North Carolina 27611 J. Michael McGarry, III, Esq.
Bishop, Liberman, Cook, Purcell Saluda River Electric Ctoperative, and Reynolds Inc.
1200 Seventeenth Street, N.W.
P.O. Box 929 Washington, D. C.
20036 Laurens, South Carolina 29360 i'
North Carolina MPA-1 Senior Resident Inspector s
i Suite 600 Route 2, Box 179N 3100 Smoketree Ct.
York, South Carolina 29745 P.O. Box 29513 Raleigh, North Carolina 27626-0513 Regional Administrator, Region II U.S. Nuclear Regulatory Comission, Mr. C. D. Markham 101 Marietta Street, NW, Suite 2900 Power Systems Division Atlanta, Georgia 30323 i
I Westinghouse Electric Corp.
P.O. Box 355 Pittsburgh, Pennsylvania 15230 Robert Guild, Esq.
2759 Rosewood Drive NUS Corporation Columbia, South Carolina 29205 i
2536 Countryside Boulevard l
Clearwater, Florida 33515 Palmetto Alliance 2759 Rosewood Drive l
Mr. Jesse L. Riley, President Columbia, South Carolina 29205 Carolina Environmental Study Group 854 Henley Place Karen E. Long Charlotte, North Carolina 28208 Assistant Attorney General l
N.C. Department of Justice Richard P. Wilson, Esq.
P.O. Box 629
~
Assistant Attorney General Raleigh, North Carolina 27602 S.C. Attorney General's Office P.O. Box 11549 Spence Perry, Esquire Columbia, South Carolina 29211 Associate General Counsel Federal Emergency Management Agency Piedmont Municipal Power Agency Room 840 100 Memorial Drive 500 C Street Greer, South Carolina 29651 Washington, D. C.
20472 Mark S. Calvert, Esq.
Mr. Michael Hirsch Bishop, Liberman, Cook, Federal Emergency Management Agency Purcell & Reynolds Office of the General Counsel 1200 17th Street, N.W.
Room 840 Washington, D. C.
20036 500 C Street, S.W.
Washington, D. C.
20472 Brian P. Cassidy, Regional Counsel Federal Emergency Management Agency, Region I J. W. McCormach P0CH Boston, Massachusetts 02109
, Catawba (amendments) cc:
Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 County Manager of York County York County Courthouse York, South Carolina 29745 Attorney General P.O. Box 11549 Columbia, South Carolina 29211 T
k e
e