Rev 2 to WP-24-SQN, Improper Welding Certification, Employee Concerns Special Program Rept
ML20210F887
Person / Time
Site: Sequoyah  
Issue date: 01/27/1987
From: Lewis J, Rose J, Schofield R
TENNESSEE VALLEY AUTHORITY
To:
Shared Package
ML20210F779 List:
References
WP-24-SQN, WP-24-SQN-R02, WP-24-SQN-R2, NUDOCS 8702110184
Download: ML20210F887 (8)


Text

___

o IVA EMPLOYEE CONCERNS REPORT NUMBER: WP-24-SQN SPECIAL PROGRAM REPORT TYPE: Welding Project REVISION NUMBER: 2 TITLE: Improper Welding Certification i

hEASON FOR REVISION: N/A

SUMMARY

STATEMENT: N/A PREPARATION PREPARED BY:

Original Signed by R. Schofield 01-21-87 SIGNATURE DATE REVIEWS PEER:

Original Signed by J. E. Rose 01-21-87 SIGNATURE DATE TAS:

SIGNATURE DATE CONCURRENCES Original Signed By CEG-H:

J. F. Lewis 01-21-87 SRP:

SIGNATURE DATE SIGNATURE

  • DATE APPROVED BY:

N/A ECSP MANAGER DATE MANAGER OF NUCLEAR POWER DATE CONCURRENCE (FINAL REPORT ONLY)

  • SRP Secretary's signature denotes SRP concurrences are in files.

8702110184 870205 2242T PDR ADOCK 05000327 P

PDR

~

WELDING PROJECT EMPLOYEE CONCERN EVALUATION REPORT REPORT NUMBER:

WP-24-SQN, R2 DATE: 0/-2 /-9 7

SUBJECT:

WELDER PERFORMANCE OUALIFICATION lR2 CONCERN (S) CONSIDERED: JLH-85-002 PREPARED BY N.

e,[

Ol J /f f'1

, OC, WP REVIEWED BY 8dh

/

fu

,aed - //-F9,' OC, WP 0

/~

/!28 !87 REVIEWED BY

, QA, WP d

6 REVIEWED BY fn w /M /

/d?-8,7CEG-H, WELDING

/ /g i

~

s APPROVED BY PROGRAM MANAGER Revision 1 issued to include comments by the Senior Review Panel and TAS.

Revision 2 rewritten to delete welder continuity issue, provide additional information about weider qualification and to specify l

corrective action 0548I

{

\\

I

e EMPLOYEE CONCERN SUNNARY SHEET Report Number: WP-24-SQN, R2 Report

Title:

Welder Performance Qualification lR2 I.

CONCERN CONSIDERED: JLH-85-002 II.

ISSUES INVOLVED 1.

Welder being qualified without the appropriate number of bend tests.

2.

A secondary issue evolving from the first concerning welder continuity was expressed by the Concerned Individual.

III. STATENENT OF CONCERN / ISSUE VALIDITY Validity: Y I

,N

, Substantiated: Y I

,N The concern that a welder has been qualified without the appropriate l

number of bend tests was substantiated and validated. This welder was l

qualified by Muscle Shoals (PSS NS) for Sequoyah Nuclear Operations lR2 (SQN NO). The statement of concern addresses only issue No. 1.

Issue l

No. 2 is addressed by CAR 85-09-14 and WP-03-SQN.

l

'IV.

EFFECT ON HARDWARE AND/OR PROGRAN To be determined through implementation of corrective action.

lR2 l

V.

JUSTIFICATION:

1.

The concern that a welder was qualified (welder qualification was l

performed by Muscio Shoals) without the appropriate number of bend l

tests was substantiated and validated. One welder has been I

retested and his qualification and previously made welds have been l

addressed by SQ-DR-85-08-095R. Additional questions were raisud lR2 during review of the DR and conversations with TVA Welding l

l personnel. It is apparent that there may have been other welders l

qualified by Muscle Shoals for SQN No with only two bend tests l

whose production work at SQN has not been addressed.

I 2563T Page 1 of 2

Report Number: WP-24-SQN, R2 VI.

RECONMENDATION AND/OR CORRECTIVE ACTION NEEDED TVA should determine whether any other welders were improperly l

qualified for SQN NO by Muscle Shoals, and what effect, if any, the lR2 improper qualifications had on work performed at SQN.

l VII.

REINSPECTION NEEDED: Y I

,N (Records review) lR2 VIII.

ISSUE CLOSURE CLOSURE BASED ON THIS REPORT l

l 1.

Issue 1 - Open l

lR2 2.

Issue 2 - Address by CAR-85-09-014 and WP-03-SQN l

IX.

ATTACHNENTS Text of Employee Concern lR2 2563T Page 2 of 2

,m

ATTACHMENT 1

~

TEST OF EMPLOYEE CONCERN Report Number: JLH-85-002 Plant: SQN This concern was not documented per SQA166 but has been included in the employee concern log.

Welders tested at Huscle Shoals for SQN NO may not have received the appropriate number of qualification tests.

i Page 1 of I

EMPLOYEE CONCERN Report Number: WP-24-SQN, R2 Report

Title:

Welder Performance Qualification IR2 I.

SCOPE OF EVALUATION JLH-85-002 The subject concern was previously investigated by the SQN onsite lR2 Employee Concern Impact Evaluation Program. Our findings and conclusions l

(in section III) are based on the review of the previous investigator's notes, review of SQN-DR-85-08-095R and discussions with cognizant TVA lR2 Welding personnel.

l L

i II.

ISSUE (S) ADDRESSED BY CONCERN A.

Welders tested at Nuscle Shoals for SQN NO may not have received the appropriate number of bend tests when taking performance qualification test.

i B.

The concerned individual also feels the current welder continuity l

program at SQN does not ensure the proficiency of Nodification lR2 Welders. This portion of the concern is addressed by CAR-85-09-14 l

and WP-03-SQN and will not be addressed in this report.

l III. CONCERN VALIDITY OR SUBSTANTIATION One welder in question was originally qualified for the Sequoyah Nuclear l

Plant at TVA's Muscle Shoals facility Based on the qualification records l

at Muscle Shoals, it is questionable if the welder was properly l

qualified. Two bend specimens per qualification test wore l

satisfactorily bent and recorded on the Welders Qualification Record.

l The ASME Code, Section IK 1974 Edition Article III, " Welding l

Performance Qualification " requires the type and number of test l

i specimens required for mechanical testing shall be in accordance with l

QW-302.3 for guided bend tests. Paragraph QW-302.3 was not printed in lR2 this edition (1974) of Section IX.

Table QW-452 specified one face bend I

and one root bend or two side bends could be substituted for the l

required face and root bend tests for thicknesses over 3/8-inch but less l

than 3/4-inch. Based on the omission, paragraph QW-302.2 could lead one l

to interpret the qualification requirement to require a two bend test.

l The Errata to the 1974 Edition of Section IX published in the l

Summer 1974 Addenda to Section IX added paragraph QW-302.3 which l

requires that four specimens (for SG and 6G positions) pass the test.

l 2563T Page 1 of 3 i

Rip;rt Numbzr: WP-24-SQN, R2 d

To provide absolute clarity to the number of bend test specimens l

required for the SG and 6G positions, the Summer Addenda to 1978 Edition l

of Section II added a foot note to table QW-453 which stated "a total l.

of four specimens is required to qualify for positions SG and 6G as lR2 prescribed in QW-302.3."

Due to the omission of paragraph QW-302.3, it I

appears that the welder's qualification was granted based on the two l

bend specimen per performance qualification test.

l Conversations with Nuscle Shoals personnel (PSS-NS) indicate that four l

bend coupons were bent per welder qualification test in the SG or 6G l

position but only two bend specimens were recorded on the Welders lR2 Qualification Records (see reply to meno dated August 14, 1985 for David l

H. Tullis to John Fox).

l The basic criterion established for welder qualification is to determine I

the welder's ability to deposit sound weld metal. The welder in l

)

question was issued 12 performance qualification from Muscle Shoals.

lR2 All 12 test were taken and successfully passed within approximately a i

three week period (08/12-09/01/77).

l The welder's continuity was maintained at SQN through at least l

August 14, 1985. On this date (August 14, 1985) the welder successfully i

completed four performance qualification tests which represents all the lR2 welding processes he had previously used at SQN. Welds made prior to l

the regualification test were addressed on SQ-DR-85-08-095R and accepted.

I Based on the fact that the welder satisfactorily performed 12 l

performance qualification tests at Nuscle Shoals, satisfactorily I

performed additional qualification testing at SQN and continued to IR2 produce satisfactory field welds over an eight year period, the intent i

of ASME Section II for welder qualification (to determine the welder's l

ability to deposit sound weld metal) was satisfied.

l The above justification, however, applies only to the one welder l

identified in SQ-DR-85-08-095R (reply meno dated 8-14-85/8-20-85).

An l

attachment to the referenced DR, states in part "... we strongly l

l recommend that you re-examine all Welder Performance Qualification test lR2 records given in 1977 by PSS NS personnel for other similar l

documentation problems..." The copy of SQ-DR-85-08-095R provided to l

the Weld Task Group (WTG) rhows no evidence of such a re-examination l

l having been performed.

l l

2563T i

Page 2 of 3 i

4

--,,.,m-e,-.

,rwm-

,m*.

-,7

, - _-,,_-m,-----_.

m-

, - -,- - _ _ - -,. = _ - -

~

R:p rt Numbar: WP-24-SQN, R2 Conversation with cognizant TVA Welding personnel indicates that a l

review was performed at SQN for NO welders which included only ws1ders l

who were active at the time of the review, and some inactive NO welders l

who had not yet been dropped from the qualification continuity list. A lR2 written record of this review could not be produced. It therefore l

appears that there may have been welders other than the one addressed I

above who were improperly qualified by PSS NS and subsequently performed l

l welding operations at SQN for NO.

l Conversation with cognizant TVA Welding personnel indicates that welder l

qualification by PSS NS for SQN NO welders continues to be a common l

practice. TVA Welding personnel believe, hcwever, that welder lR2 performance qualification at Muscle Shoals with only two bend tests l

documented was limited to a time frame of approximately three years, l

from January 1975 through December 1977.

l IV.

CORRECTIVE ACTION TVA should determine the exact time frame during which PSS MS provided l

welder qualification services to SQN NO without evidence of having lR2 performed the Code required number of bend tests.

l TVA should determine whether or not any PSS NS qualified welders other l

than the one addressed by SQ-DR-85-08-095R received their qualifications lR2 during the above determined time frame, and subsequently performed l

welding operations for SQN NO.

l TVA should evaluate for acceptability any welding performed at SQN by l

welders identified as having been improperly qualified by PSS MS.

lR2 It should be noted that TVA Welding personnel believe that the above l

actions have, in part, been accomplished. In that whatever action was l

taken was apparently not formally documented, it cannot be established l

to what degree the problem originally extended, or to what degree it was lR2 evaluated and resolved. Therefore, when the above corrective actions l

are undertaken, they should be formally documented. Any deficiencies l

l identified should be documented in accordance with the established TVA l

l deficiency reporting and tracking program.

l l

2563T Page 3 of 3