ML20207P624

From kanterella
Jump to navigation Jump to search
Forwards Engineering Branch Safety Evaluation Accepting Util 851120 & 860324 Proposals for Elimination of Arbitrary Intermediate Pipe Breaks in High Energy Lines
ML20207P624
Person / Time
Site: Catawba  
Issue date: 01/14/1987
From: Jabbour K
Office of Nuclear Reactor Regulation
To: Tucker H
DUKE POWER CO.
Shared Package
ML20207P625 List:
References
NUDOCS 8701160332
Download: ML20207P624 (2)


Text

.

docketNos.: 50-413-and 50-414 14 JAN 1987 Mr. H. B. Tucker, Vice President Nuclear Production Department Duke Power Company 422 South Church Street Charlotte, fiorth Carolina 28242

Dear Mr. Tucker:

Subject:

ELIMINATION OF ARBITRARY INTERMEDIATE PIPE BREAKS - CATAWBA fiUCLEAR STATION, UNITS 1 AND 2 By letter dated November 20, 1985, and supplemented March 24, 1986, you forwarded for NRC review and approval, a technical document proposing the elimination of certain arbitrary interrediate pipe breaks in high energy lines (other than the RCS primary loops) for Catawba Nuclear Station, Unit 1, and in the Pressurizer Surge Line and the Main Feedwater Line for Unit 2.

By letter dated April 2,1984, the NRC staff approved the elimination of this type of breaks Main Feedwater Line)gy piping systems (other than the Pressurizer Surge Line and in certain high ener for Catawba Unit 2.

The staff has completed its review of your submittals.

Enclosed is our Safety Evaluation Report in which we find that your proposal is an acceptable deviation from Section 3.6.2 of the Standard Review Plan (NUREG-0800, Revision 1).

Please contact te at (301) 492-7367 if you have any questions regarding the enclosure.

Sincerely, Kahtan Jabbour, Project fianager PKR Project Directorate #4 Division of PWR Licensing-A

Enclosure:

As stated cc: See next page DISTRIBUTION:

c64 flRC PDR HBrammer

  • L'ocal FDR~ ~#

PRC System GBagchi PWR#4/Rdg MDuncan ESullivan KJabbocur OGC-Bethesda RBallard ACRS (10)

JPartlow CRossi BGrimes EJordan CMcCracken NThompson

- PWR#dg/ rad P

-A PWR#4/ WR-A PW Fyl)P:R-A MDuncan KJabbour BJ aunqh,l od 01/y /87 01/(f/87 01/gb G701160332 870114 PDR ADOCK 05000413 P

PDR 3

4 Mr. H. B. Tucker Duke Power Company Catawba ?!uclear Station CC:

A.V. Carr, Esq.

florth Carolina Electric Membership Duke Power Company Coro.

422 South Church Street 3400 Sumner Boulevard l

Charlotte, North Carolina 28242 P.O. Box 27306 Raleigh, North Carolinc 276!]

i J. Michael McGarry, III, Eso.

Bishop, Liberman, Cook, Purcell Saluda River Electric Cooperative, and Reynolos Inc.

1200 Seventeenth Street, N.W.

P.O. Box 929 Vashington, D. C.

20036 Laurens, South Carolina 29360 North Carolina MPA-1 Senior Resicent Inspector Suite 600 Rcute 2, Box 179N 3100 Smoketree Ct.

York, South Carolina 29745' P.O. Box 29513 Raleigh, North Carolina 27626-0513 Regional Administrator, Region II U.S. Nuclear Regulatory Commission, L.L. Williams 101 Marietta Street, NW, Suite 2900 Area Manager, Mid-South Area Atlanta, Georgia 30323 ESSD Projects Westinghouse Electric Corp.

MNC West Tower - Bay 239 P.O. Box 355 Pittsburgh, Pennsylvania 15230 Nr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina DeDartment of Health and Environmentel Ccntrol 2600 Bull Street Columbia, South Carolina 29201 County Manager of York County York County Courthouse Karen E. Long York South Carolina 29745 Assistant Attorrey Ccneral h.C. Department of Justice Richard P. Wilson, Esq.

P.O. Boy 629 Assistant Attorney General Ralcipb, North Carolina 27602 S.C. Attorney General's Office P.O. Box 11549 Spence Perry, Esquire Colurabia, S'uth Carolina 29211 General Counsel Federal Emergency Management Agency Piedmont Municipal Power Agency Room 840 100 Memorial Drive 500 C Street Greer, South Carolina 29651 Washington, D. C.

20472 Mr. Michael Hirsch Federal Er'ergency Management Agency Office of the General Counsel Room 840 500 C Street, S.W.

Washington, D. C.

20472 i

l Brian P. Cassidy, Regional Counsel l

Federal Emergency Management Agency, l

Region I J. W. McCormach POCH Boston, Massachusetts 02109